Application of ultrafiltration membranes for removal of humic acid from drinking water

被引:110
|
作者
Lowe, J. [1 ]
Hossain, Md. M. [1 ]
机构
[1] Univ Auckland, Dept Chem & Mat Engn, Auckland, New Zealand
关键词
humic acid; ultrafiltration; membrane; flux; removal;
D O I
10.1016/j.desal.2007.02.030
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Humic acids are primarily a result of the microbiological degradation of surrounding vegetation and animal decay and enter surface waters through rain water run-off from the surrounding land. This often gives rise to large seasonal variations, high concentrations in the wet season and lower concentrations in the dry season. Alone humic acid is just a colour problem but when present in conventional treatment processes like chlorination, carcinogenic by-products like trihalomethane and haloacetic acid are formed. This, in addition to the demand for clean potable drinking water, has sparked extensive research into alternative processes for the production of drinking water from various natural/industrial sources. One of the major areas of focus in these studies is the use of membranes in microfiltration, ultrafiltration and nanofiltration. In this report the humic acid removal efficiency of ultrafiltration membranes with 3 kDa, 5 kDa and 10 kDa MWCO is examined. The membranes were made of regenerated cellulose and were in the form of cassette providing a 0.1 m(2) surface area. At first distilled and deionised water, known as milliQ water, was used as the background feed solution to which humic acid powder was added. It was found that all three membranes removed humic acid with an efficiency of approx. 90% and were capable of reducing initial concentrations of 15mg/L to below the New Zealand regulatory limit of 1.17 mg/L. The permeate flux at a transmembrane pressure of 2.1 bar was approx. 20 l/m(2)/h (LMH) and 40 LMH, respectively through the membranes with MWCO 3 kDa and 5 kDa. These membranes experienced significant surface fouling resulting in retentate flow rates as low as I I litres per hour after just four runs compared to the recommended 60-90 l/h. Cleaning with 0.1 M NaOH slightly improved the retentate flow rate, but well below those obtained with fresh membranes. The 10 kDa membrane provided high retentate flow rates which evidently minimised fouling by providing a good sweeping action across the membrane surface while maintaining humic acid removal below the regulatory 1.17 mg/L level. The permeate flux through this membrane was initially high (140-180 LMH) and reduced to approx. 100 LMH after 10-12 min of operation. Increasing the initial humic acid feed concentration from 10 mg/L to 50 mg/L did not significantly decrease humic acid removal efficiency although the retentate flow rate was lower at higher concentrations. Finally the tap water was tested as the background solution and treated for the removal of humic acid. The presence of ions and other impurities in the tap water had little effect on humic acid removal. However, the permeate flux through 10 kDa membrane decreased from 100 LMH for milliQ water to 60 LMH for tap water after 20 min of operation.
引用
收藏
页码:343 / 354
页数:12
相关论文
共 50 条
  • [31] Photocatalytic Membrane Reactor (PMR) for Virus Removal in Drinking Water: Effect of Humic Acid
    Cheng, Rong
    Shen, Liangjie
    Wang, Qi
    Xiang, Shaoyu
    Shi, Lei
    Zheng, Xiang
    Lv, Wenzhou
    CATALYSTS, 2018, 8 (07)
  • [32] Removal of arsenic and pesticides from drinking water by nanofiltration membranes
    Kosutic, K
    Furac, L
    Sipos, L
    Kunst, B
    SEPARATION AND PURIFICATION TECHNOLOGY, 2005, 42 (02) : 137 - 144
  • [33] Arsenic removal from drinking water using clay membranes
    Fang, J
    Deng, BL
    Whitworth, TM
    ADVANCES IN ARSENIC RESEARCH: INTEGRATION OF EXPERIMENTAL AND OBSERVATIONAL STUDIES AND IMPLICATIONS FOR MITIGATION, 2005, 915 : 294 - 305
  • [34] Treatment of spent filter backwash water from drinking water treatment with immersed ultrafiltration membranes
    Curko, Josip
    Mijatovic, Ivan
    Rumora, Dean
    Crnek, Vlado
    Matosic, Marin
    Nezic, Mladen
    DESALINATION AND WATER TREATMENT, 2013, 51 (25-27) : 4901 - 4906
  • [35] Evaluation of graphene oxide-coated ultrafiltration membranes for humic acid removal at different pH and conductivity conditions
    Chu, Kyoung Hoon
    Huang, Yi
    Yu, Miao
    Heo, Jiyong
    Flora, Joseph R. V.
    Jang, Am
    Jang, Min
    Jung, Chanil
    Park, Chang Min
    Kim, Do-Hyung
    Yoon, Yeomin
    SEPARATION AND PURIFICATION TECHNOLOGY, 2017, 181 : 139 - 147
  • [36] Removal of Fluoride from drinking water by an activated Bentonite: application to a drinking Tunisian water
    Hadjyoussef, Mouna Touati
    Jendoubi, Montassar
    Ben Amor, Mohamed
    Benna-Zayani, Memia
    MOROCCAN JOURNAL OF CHEMISTRY, 2018, 6 (01): : 135 - 147
  • [37] Drinking water treatment by using ultrafiltration hollow fiber membranes
    Nakatsuka, S
    Nakate, I
    Miyano, T
    DESALINATION, 1996, 106 (1-3) : 55 - 61
  • [38] Surface-coated PVDF@TAPEG selective ultrafiltration membranes: an investigation on membranes' hydrophilicity, and antifouling characteristics for effective humic acid removal from wastewater
    Emadinezhad, Leila
    Ayati, Bita
    APPLIED WATER SCIENCE, 2024, 14 (10)
  • [39] Ultrathin graphene oxide membranes for the removal of humic acid
    Song, Julie J.
    Huang, Yi
    Nam, Seung-Woo
    Yu, Miao
    Heo, Jiyong
    Her, Namguk
    Flora, Joseph R. V.
    Yoon, Yeomin
    SEPARATION AND PURIFICATION TECHNOLOGY, 2015, 144 : 162 - 167
  • [40] Graphene oxide membranes for effective removal of humic acid
    Xiaojun Ren
    Dali Ji
    Xinyue Wen
    Heriberto Bustamante
    Rahman Daiyan
    Tobias Foller
    Yee Yee Khine
    Rakesh Joshi
    Journal of Materials Research, 2022, 37 : 3362 - 3371