Glaucoma Filtering Bleb Analysis Before and After Aponeurotic Blepharoptosis Surgery

被引:2
|
作者
Yunoki, Tatsuya [1 ]
Tojo, Naoki [1 ]
Oiwake, Toshihiko [1 ]
Otsuka, Mitsuya [1 ]
Hayashi, Atsushi [1 ]
机构
[1] Univ Toyama, Grad Sch Med & Pharmaceut Sci, Dept Ophthalmol, 2630 Sugitani, Toyama 9300194, Japan
来源
关键词
MUSCLE-CONJUNCTIVA RESECTION; ANTERIOR SEGMENT SURGERY; PTOSIS; TRABECULECTOMY;
D O I
10.1097/IOP.0000000000001456
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
In patients with glaucoma filtering bleb, transcutaneous levator aponeurotic ptosis surgery is considered to be highly safe and unlikely to affect the morphology of the filtering bleb or intraocular pressure in the short term. Purpose: To evaluate the effectiveness and safety of aponeurotic blepharoptosis surgery and the morphology of filtering bleb in patients with filtrating bleb. Methods: This retrospective case series included 7 consecutive patients (9 eyes) with filtering bleb after trabeculectomy. They underwent transcutaneous levator aponeurotic advancement from May 2018 to April 2019. The authors evaluated margin reflex distance-1 and intraocular pressure and analyzed filtering bleb morphology, such as filtering bleb volume, filtering bleb height, and filtering bleb wall thickness, using anterior segment optical coherence tomography before and after aponeurotic advancement. The authors also evaluated intra and postoperative complications. Results: The mean age was 75.6 +/- 7.8 years; the mean duration from glaucoma surgery to blepharoptosis surgery was 36.9 +/- 26.8 months; the mean follow-up after blepharoptosis surgery was 6.1 +/- 2.9 months. The mean margin reflex distance-1 value changed significantly from 0.7 +/- 0.8 mm before surgery to 3.3 +/- 0.4 mm after surgery (p < 0.0001). The mean intraocular pressure showed no significant change from 12.9 +/- 2.6 mm Hg before surgery to 12.7 +/- 3.3 after surgery. In the filtering bleb analysis using anterior segment optical coherence tomography no significant differences were found, such as in bleb volume, height and wall thickness, before and after blepharoptosis surgery. There were no intraoperative complications in any of the cases. A postoperative corneal disorder was seen in 1 eye, but there was no infection of or damage to filtering bleb in any of the cases during the postoperative follow-up period. Conclusions: In patients with glaucoma filtering bleb, transcutaneous levator aponeurotic ptosis surgery is considered to be safe and unlikely to affect the morphology of the filtering bleb or intraocular pressure in the short term.
引用
收藏
页码:45 / 48
页数:4
相关论文
共 50 条
  • [1] Comparison of postoperative course of aponeurotic ptosis surgery in eyes with glaucoma filtration bleb and in eyes after intraocular surgery without bleb
    Yamamoto, Risako
    Shirakawa, Rika
    Toyono, Tetsuya
    Sakata, Rei
    Akiyama, Reina
    Aoyama, Yurika
    Noda, Mika
    Yoshida, Junko
    Miyai, Takashi
    Usui, Tomohiko
    Aihara, Makoto
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [2] Procedure of aponeurotic blepharoptosis surgery
    Yabe, Tetsuji
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2010, 63 (01): : E73 - E74
  • [3] Late-onset bleb leaks after glaucoma filtering surgery
    Jee, J
    Greenfield, DS
    Liebmann, JM
    Patelska, B
    Ishikawa, H
    Ritch, R
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4980 - 4980
  • [4] Late-onset bleb leaks after glaucoma filtering surgery
    Greenfield, DS
    Liebmann, JM
    Jee, J
    Ritch, R
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (04) : 443 - 447
  • [5] The oculocardiac reflex in aponeurotic blepharoptosis surgery
    Uda, Hirokazu
    Sugawara, Yasusih
    Sarukawa, Syunji
    Sunaga, Ataru
    [J]. JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2014, 48 (03) : 170 - 174
  • [6] Long term follow-up of bleb reconstruction after glaucoma filtering surgery
    Bresson-Dumont, H.
    Lehoux, A.
    Foucher, J.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2009, 32 (03): : 241 - 246
  • [8] Outcomes of bleb revision with ologen following filtering glaucoma surgery
    Kornmann, Helen L.
    Fellman, Ronald L.
    Smith, Oluwatosin U.
    Godfrey, David G.
    Butler, Michelle R.
    Grover, Davinder S.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (04) : 2241 - 2248
  • [9] Outcomes of Bleb Excision With Free Autologous Conjunctival Patch Grafting for Bleb Leak and Hypotony After Glaucoma Filtering Surgery
    Panday, Manish
    Shantha, Balekudaru
    George, Ronnie
    Boda, Shilpa
    Vijaya, Lingam
    [J]. JOURNAL OF GLAUCOMA, 2011, 20 (06) : 392 - 397
  • [10] Glaucoma filtering bleb dysesthesia
    Budenz, DL
    Hoffman, K
    Zacchei, A
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 131 (05) : 626 - 630