Outcomes of bleb revision with ologen following filtering glaucoma surgery

被引:1
|
作者
Kornmann, Helen L. [1 ]
Fellman, Ronald L. [1 ]
Smith, Oluwatosin U. [1 ]
Godfrey, David G. [1 ]
Butler, Michelle R. [1 ]
Grover, Davinder S. [1 ]
机构
[1] Glaucoma Associates Texas, 10740 N Cent Expy,Suite 300, Dallas, TX 75231 USA
关键词
Ologen; bleb revision; bleb leak; dysesthesia; hypotony; AUTOLOGOUS BLOOD INJECTION; TREAT OCULAR HYPOTONY; LEAKING BLEBS; MITOMYCIN-C; SUBCONJUNCTIVAL IMPLANTATION; CONJUNCTIVAL ADVANCEMENT; SURGICAL REDUCTION; COLLAGEN MATRIX; TRABECULECTOMY; MANAGEMENT;
D O I
10.1177/11206721211053503
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose This study reports long-term outcomes of bleb revision with ologen (TM) Collagen Matrix (Aeon Astron Europe BV, the Netherlands) for the surgical management of various bleb-related issues including persistent bleb leaks with or without associated hypotony, bleb dysesthesia, overhanging blebs, or hypotony after filtering glaucoma surgery. Materials and methods A retrospective chart review was performed for patients who underwent ologen bleb revision from 2012 to 2019 at Glaucoma Associates of Texas. Results The study included 23 eyes of 22 patients undergoing bleb revision with the ologen implant. Mean age was 74.0 +/- 11.3 years, 16 (69.6%) were female, and 13 (56.5%) were White. Indications for bleb revision included bleb leak (78.3%), dysesthesia (13.0%), and hypotony from an overfiltering bleb (8.7%). Mean preoperative intraocular pressure was 6.8 +/- 4.1 mmHg and the number of medications was 0.3 +/- 0.9. Median follow-up was 24 months (range: 12-84 months); all patients had at least 12 months of follow-up. At 1 year, mean intraocular pressure was 10.9 +/- 4.6 mmHg on 0.2 +/- 0.5 medications, and at last follow-up, mean intraocular pressure was 10.4 +/- 3.6 mmHg on 0.3 +/- 0.7 medications. Bleb morphology remained low, diffuse, and posterior. One patient developed kissing choroidal effusions requiring surgical drainage with subsequent stabilization of intraocular pressure and bleb function, and three patients required additional surgery due to persistent leaks or bleb failure; there were no other vision-threatening complications. Conclusions Use of the ologen implant during surgical bleb revision is a useful surgical technique that confers long-term improvements in bleb morphology and stability of function.
引用
收藏
页码:2241 / 2248
页数:8
相关论文
共 50 条
  • [1] Needling Revision Outcomes Following Glaucoma Filtering Surgery
    Kizy, Bianca
    Hughes, Bret A.
    Shukairy, Aman
    Goyal, Anju
    Tannir, Justin
    Juzych, Mark S.
    Rana, Sonia
    Kim, Chaesik
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [2] Outcomes of Combined subconjunctival with subscleral Ologen implant in glaucoma filtering surgery
    Angmo, Dewang
    Falera, Ruchita
    Singh, Archita
    Sinha, Gautam
    Patil, Bharat
    Dada, Tanuj
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [3] Upper eyelid extension of a filtering bleb following glaucoma shunt surgery
    Younger, Jared R.
    Kooner, Karanjit S.
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2006, 37 (04) : 324 - 326
  • [4] Long-Term Outcomes of Bleb Needling Following Primary Glaucoma Filtering Surgery in Primary Open Angle Glaucoma
    Turco, Bryen
    Patel, Vaama
    Kim, Chaesik
    Tannir, Justin
    Keshishian, Lauren
    Goyal, Anju
    Juzych, Mark
    Hughes, Bret
    Al-Timimi, Faisal Ridha
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [5] REVISION OF GLAUCOMA FILTERING SURGERY
    BUDENZ, D
    SINGH, K
    PARRISH, RK
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 734 - 734
  • [6] A COMPARISON OF SURGICAL OUTCOMES OF TUBE SHUNT SURGERY, BLEB NEEDLE REVISION AND REVISION TRABECULECTOMY FOLLOWING FAILED TRABECULECTOMY IN A TERTIARY GLAUCOMA UNIT
    Cui, Peter
    Atik, Alp
    Baker, Michelle
    Liu, Lei
    Kwon, Hye Jin
    Liu, Qin Qin
    Kong, George
    Gaskin, Jennifer Fan
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 : 104 - 104
  • [7] Clinical Impact of the Use of Ologen in Filtering Surgery Performed in Uncontrolled Glaucoma
    Navero-Rodriguez, Jose-Manuel
    Boldu-Roig, Julia
    Pinilla, Laura
    Vidal-Marti, Maria
    Anton, Alfonso
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (15)
  • [8] Outcomes of Bleb Excision With Free Autologous Conjunctival Patch Grafting for Bleb Leak and Hypotony After Glaucoma Filtering Surgery
    Panday, Manish
    Shantha, Balekudaru
    George, Ronnie
    Boda, Shilpa
    Vijaya, Lingam
    [J]. JOURNAL OF GLAUCOMA, 2011, 20 (06) : 392 - 397
  • [9] Outcomes of bleb excision and conjunctival advancement for leaking or hypotonous eyes after glaucoma filtering surgery
    Tannenbaum, DP
    Hoffman, D
    Greaney, MJ
    Caprioli, J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (01) : 99 - 103