Contrast-Enhanced Anatomic Imaging as Compared to Contrast-Enhanced Tissue Characterization for Detection of Left Ventricular Thrombus

被引:159
|
作者
Weinsaft, Jonathan W. [1 ,2 ]
Kim, Raymond J. [3 ]
Ross, Michael [1 ]
Krauser, Daniel [1 ]
Manoushagian, Shant [1 ]
LaBounty, Troy M. [1 ]
Cham, Matthew D. [1 ,2 ]
Min, James K. [1 ,2 ]
Healy, Kirsten [1 ]
Wang, Yi [2 ]
Parker, Michele [3 ]
Roman, Mary J. [1 ]
Devereux, Richard B. [1 ]
机构
[1] Weill Cornell Med Coll, Dept Med, Div Cardiol, New York, NY 10021 USA
[2] Weill Cornell Med Coll, Dept Radiol, New York, NY 10021 USA
[3] Duke Cardiovasc Magnet Resonance Ctr, Durham, NC USA
关键词
thrombus; cardiac magnetic resonance; echocardiography; CARDIOVASCULAR MAGNETIC-RESONANCE; MYOCARDIAL-INFARCTION; ECHOCARDIOGRAPHY; VISUALIZATION;
D O I
10.1016/j.jcmg.2009.03.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to compare contrast-enhanced anatomic imaging and contrast-enhanced tissue characterization (delayed-enhancement cardiac magnetic resonance [DE-CMR]) for left ventricular (LV) thrombus detection. BACKGROUND Contrast echocardiography (echo) detects LV thrombus based on anatomic appearance, whereas DE-CMR imaging detects thrombus based on tissue characteristics. Although DE-CMR has been validated as an accurate technique for thrombus, its utility compared with contrast echo is unknown. METHODS Multimodality imaging was performed in 121 patients at high risk for thrombus due to myocardial infarction or heart failure. Imaging included 3 anatomic imaging techniques for thrombus detection (contrast echo, noncontrast echo, cine-CMR) and a reference of DE-CMR tissue characterization. LV structural parameters were quantified to identify markers for thrombus and predictors of additive utility of contrast-enhanced thrombus imaging. RESULTS Twenty-four patients had thrombus by DE-CMR. Patients with thrombus had larger infarcts (by DE-CMR), more aneurysms, and lower LV ejection fraction (by CMR and echo) than those without thrombus. Contrast echo nearly doubled sensitivity (61% vs. 33%, p < 0.05) and yielded improved accuracy (92% vs. 82%, p < 0.01) versus noncontrast echo. Patients who derived incremental diagnostic utility from DE-CMR had lower LV ejection fraction versus those in whom noncontrast echo alone accurately assessed thrombus (35 +/- 9% vs. 42 +/- 14%, p < 0.01), with a similar trend for patients who derived incremental benefit from contrast echo (p < 0.08). Contrast echo and cine-CMR closely agreed on the diagnosis of thrombus (kappa = 0.79, p < 0.001). Thrombus prevalence was lower by contrast echo than DE-CMR (p < 0.05). Thrombus detected by DE-CMR but not by contrast echo was more likely to be mural in shape or, when apical, small in volume (p < 0.05). CONCLUSIONS Echo contrast in high-risk patients markedly improves detection of LV thrombus, but does not detect a substantial number of thrombi identified by DE-CMR tissue characterization. Thrombi detected by DE-CMR but not by contrast echo are typically mural in shape or small in volume. (J Am Coll Cardiol Img 2009;2:969-79) (C) 2009 by the American College of Cardiology Foundation
引用
收藏
页码:969 / 979
页数:11
相关论文
共 50 条
  • [21] Contrast-Enhanced Microwave Breast Imaging
    Shea, Jacob D.
    Kosmas, Panagiotis
    Hagness, Susan C.
    Van Veen, Barry D.
    2009 13TH INTERNATIONAL SYMPOSIUM ON ANTENNA TECHNOLOGY AND APPLIED ELECTROMAGNETICS AND THE CANADIAN RADIO SCIENCES MEETING (ANTEM/URSI 2009), 2009, : 298 - 301
  • [22] Contrast-enhanced cardiac MR imaging
    Schneider, G
    Fries, P
    Ahlhelm, F
    Kindermann, I
    Kramann, B
    Böhm, M
    EUROPEAN RADIOLOGY, 2003, 13 (Suppl 3) : N11 - N18
  • [23] Contrast-enhanced MR imaging of the liver
    VanBeers, BE
    Gallez, B
    Pringot, J
    RADIOLOGY, 1997, 203 (02) : 297 - 306
  • [24] CONTRAST-ENHANCED MR IMAGING OF THE LIVER
    SAINI, S
    RADIOLOGY, 1992, 182 (01) : 12 - 14
  • [25] Contrast-enhanced pulmonary MR imaging
    Olav Haraldseth
    Tore Amundsen
    Peter A. Rinck
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1999, 8 (3) : 146 - 153
  • [26] Contrast-enhanced ultrasound in abdominal imaging
    Carlos Nicolau
    Tomás Ripollés
    Abdominal Imaging, 2012, 37 : 1 - 19
  • [27] Contrast-enhanced pulmonary MR imaging
    Haraldseth, Olav
    Amundsen, Tore
    Rinck, Peter A.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1999, 8 (03) : 146 - 153
  • [28] Contrast-Enhanced MR Imaging in Neuroimaging
    Kim, Bum-soo
    Gutierrez, Juan E.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 649 - +
  • [29] Comparison of contrast-enhanced digital mammography and contrast-enhanced digital breast tomosynthesis for lesion assessment Comparison of contrast-enhanced
    Huang, Hailiang
    Scaduto, David A.
    Liu, Chunling
    Yang, Jie
    Zhu, Chencan
    Rinaldi, Kim
    Eisenberg, Jason
    Liu, Jingxuan
    Hoernig, Mathias
    Wicklein, Julia
    Vogt, Sebastian
    Mertelmeier, Thomas
    Fisher, Paul R.
    Zhao, Wei
    JOURNAL OF MEDICAL IMAGING, 2019, 6 (03)
  • [30] Contrast-enhanced ultrasound in abdominal imaging
    Nicolau, Carlos
    Ripolles, Tomas
    ABDOMINAL IMAGING, 2012, 37 (01): : 1 - 19