Physical characterization of a prototype selenium-based full field digital mammography detector

被引:46
|
作者
Saunders, RS [1 ]
Samei, E
Jesneck, JL
Lo, JY
机构
[1] Duke Univ, Dept Phys, Duke Adv Imaging Labs, Durham, NC 27710 USA
[2] Duke Univ, Dept Radiol, Duke Adv Imaging Labs, Durham, NC 27710 USA
[3] Duke Univ, Dept Biomed Engn, Duke Adv Imaging Labs, Durham, NC 27710 USA
关键词
image quality; mammography; modulation transfer function; normalized noise power spectrum; detective quantum efficiency; digital imaging;
D O I
10.1118/1.1855033
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to measure experimentally the physical performance of a prototype mammographic imager based on a direct detection, flat-panel array design employing an amorphous selenium converter with 70 mum pixels. The system was characterized for two different anode types, a molybdenum target with molybdenum filtration (Mo/Mo) and a tungsten target with rhodium filtration (W/Rh), at two different energies, 28 and 35 kVp, with approximately 2 mm. added aluminum filtration. To measure the resolution, the presampled modulation transfer function (MTF) was measured using an edge method. The normalized noise power spectrum (NNPS) was measured by two-dimensional Fourier analysis of uniformly exposed mammograms. The detective quantum efficiencies (DQEs) were computed from the MTFs, the NNPSs, and theoretical ideal signal to noise ratios. The MTF was found to be close to its ideal limit and reached 0.2 at 11.8 mm(-1) and 0.1 at 14.1 mm(-1) for images acquired at an RQA-M2 technique (Mo/Mo anode, 28 kVp, 2 mm Al). Using a tungsten technique (MW2; W/Rh anode, 28 kVp, 2 mm Al), the MTF went to 0.2 at 11.2 mm(-1) and to 0.1 at 13.3 mm(-1). The DQE reached a maximum value of 54% at 1.35 mm(-1) for the RQA-M2 technique at 1.6 muC/kg and achieved a peak value of 64% at 1.75 mm(-1) for the tungsten technique (MW2) at 1.9 muC/kg. Nevertheless, the DQE showed strong exposure and frequency dependencies. The results indicated that the detector offered high MTFs and DQEs, but structured noise effects may require improved calibration before clinical implementation. (C) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:588 / 599
页数:12
相关论文
共 50 条
  • [1] Detector evaluation of a prototype amorphous selenium-based full field digital mammography system
    Jesneck, JL
    Saunders, RS
    Samei, E
    Xia, JQ
    Lo, JY
    [J]. MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 478 - 485
  • [2] Characterization of a full field digital mammography detector based on direct x-ray conversion in selenium
    Yorker, JG
    Jeromin, LS
    Lee, DLY
    Palecki, EF
    Golden, KP
    Jing, ZX
    [J]. MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 21 - 29
  • [3] Physical characteristics of a clinical prototype for full-field digital mammography with an a-Se flat panel detector
    Lazzari, B
    Belli, G
    Gori, C
    Nykdnen, K
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 656 - 666
  • [4] Modulation transfer function of a selenium-based digital mammography system
    Hoheisel, M.
    Baetz, L.
    Mertelmeier, T.
    Giersch, J.
    Korn, A.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1118 - 1122
  • [5] Modulation transfer function of a selenium-based digital mammography system
    Hoheisel, M
    Bätz, L
    Mertelmeier, T
    Giersch, J
    Korn, A
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3589 - 3593
  • [6] CCD-based detector for full-field digital mammography
    Stanton, M
    Phillips, W
    Stewart, A
    Smilowitz, L
    Williams, MB
    Simoni, P
    Ingersoll, C
    McCauley, T
    Qian, H
    [J]. MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 740 - 748
  • [7] Full breast digital mammography with an amorphous silicon-based flat panel detector: Physical characteristics of a clinical prototype
    Vedantham, S
    Karellas, A
    Suryanarayanan, S
    Albagli, D
    Han, S
    Tkaczyk, EJ
    Landberg, CE
    Opsahl-Ong, B
    Granfors, PR
    Levis, I
    D'Orsi, CJ
    Hendrick, RE
    [J]. MEDICAL PHYSICS, 2000, 27 (03) : 558 - 567
  • [8] Radiation exposure in full-field digital mammography with a selenium flat-panel detector
    Gosch, D.
    Jendrass, S.
    Scholz, M.
    Kahn, T.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (07): : 693 - 697
  • [9] Imaging characteristics of a direct conversion full-field digital mammography detector using selenium
    Lee, DL
    Yorker, JG
    Jing, ZX
    Jeromin, LS
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 43 - 47
  • [10] First results with real-time selenium-based full-field digital mammography three-dimensional imaging system
    Lehtimäki, M
    Pamilo, M
    Raulisto, L
    Kalke, M
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 922 - 929