Outcomes of tibial avulsion fracture of the posterior cruciate ligament treated with a homemade hook plate

被引:11
|
作者
Liu, Hao [1 ]
Liu, Jun [1 ]
Wu, Yongwei [1 ]
Ma, Yunhong [1 ]
Gu, Sanjun [2 ]
Mi, Jingyi [2 ]
Rui, Yongjun [1 ]
机构
[1] Soochow Univ, Wuxi Peoples Hosp 9, Dept Traumat Orthoped, NO 999 Liangxi Rd, Wuxi, Jiangsu, Peoples R China
[2] Soochow Univ, Wuxi Peoples Hosp 9, Dept Sports Med, Wuxi, Jiangsu, Peoples R China
关键词
Postero-medial approach; Homemade hook plate; PCL tibial avulsion; FIXATION;
D O I
10.1016/j.injury.2021.04.042
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare the clinical effects of an inverted L-shaped postero-medial approach with a homemade hook plate and arthroscopic fixation with Endobutton for tibial avulsion fractures of the posterior cruciate ligament. Methods: The clinical data of 36 patients with PCL tibial avulsion fractures from January 2012 to December 2019 were analyzed retrospectively. The fractures were classified into Meyers-McKeever types II and III. Among them, 20 cases were treated with a homemade hook plate through an inverted L-shaped postero-medial approach (incision group), and 16 cases were treated with Endobutton under arthroscopy (arthroscopic group). The operative time, fracture union time, operative complications and range of motion of the knee joint were compared between the two groups. The stability of the knee joint was tested by the posterior drawer test, the functional recovery of the knee joint was evaluated by the Lysholm score, and the gastrocnemius muscle strength of the incision group was tested by performing heel raises with a single leg stance. Results: There were no adverse events, such as fracture nonunion, infection, deep-vein thrombosis, abnormal hematoma or joint stiffness, in either group. The operative time was shorter in the incision group, and the difference was statistically significant (P < 0.05). There was no significant difference in fracture union time between the two groups (P > 0.05). At the last follow-up, there was no significant difference in range of motion or the Lysholm score between the two groups. There was no decrease in gastrocnemius muscle strength in the incision group. Conclusions: The fixation of PCL tibial avulsion fractures with a homemade hook plate through an inverted L-shaped postero-medial approach is safe and effective. It showed almost the same satisfactory outcomes as arthroscopic Endobutton fixation. (c) 2021 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
引用
收藏
页码:1934 / 1938
页数:5
相关论文
共 50 条
  • [31] Outcomes of posterior cruciate ligament tibial avulsion treated with staple fixation: stress TELOS X-ray evaluation
    M. M. Reverte-Vinaixa
    J. H. Nuñez
    D. Muñeton
    N. Joshi
    E. Castellet
    J. Minguell
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 883 - 891
  • [32] Displaced avulsion fractures of the posterior cruciate ligament: Treated by stellate steel plate fixation
    Lijun Li
    Wei Tian
    Indian Journal of Orthopaedics, 2015, 49 : 171 - 175
  • [33] Displaced avulsion fractures of the posterior cruciate ligament: Treated by stellate steel plate fixation
    Li, Lijun
    Tian, Wei
    INDIAN JOURNAL OF ORTHOPAEDICS, 2015, 49 (02) : 171 - 175
  • [34] Treatment of avulsion fracture of posterior cruciate ligament tibial insertion by minimally invasive approach in posterior medial knee
    Guo, Huihui
    Zhao, Yao
    Gao, Liang
    Wang, Chen
    Shang, Xianbo
    Fan, Haitao
    Cheng, Wendan
    Liu, Chang
    FRONTIERS IN SURGERY, 2023, 9
  • [35] Avulsion fractures of both anterior and posterior cruciate ligament tibial insertions
    O. Calpur
    C. Copuroglu
    M. Ozcan
    Knee Surgery, Sports Traumatology, Arthroscopy, 2002, 10 : 223 - 225
  • [36] Management of Posterior Cruciate Ligament Tibial Avulsion Injuries A Systematic Review
    Hooper, Perry O., III
    Silko, Chris
    Malcolm, Tennison L.
    Farrow, Lutul D.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2018, 46 (03): : 734 - 742
  • [37] Avulsion fractures of both anterior and posterior cruciate ligament tibial insertions
    Calpur, OU
    Copuroglu, C
    Ozcan, M
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (04) : 223 - 225
  • [38] Biomechanical study of posterior cruciate ligament tibial arrest avulsion fracture fixation with triple tibial channel net sutures
    Li, Yuan
    Liu, Jun-Cai
    Wu, Ju
    Peng, Xu
    Sun, Guan-Jun
    Li, Zhong
    Yin, Yi
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [39] Biomechanical study of posterior cruciate ligament tibial arrest avulsion fracture fixation with triple tibial channel net sutures
    Yuan Li
    Jun-Cai Liu
    Ju Wu
    Xu Peng
    Guan-Jun Sun
    Zhong Li
    Yi Yin
    Scientific Reports, 13
  • [40] Study of double button plate and cannulated screw fixation for posterior cruciate ligament avulsion fracture
    Sun, Kai
    Fan, Meng
    FRONTIERS IN SURGERY, 2023, 9