A suction-type microfluidic immunosensing chip for rapid detection of the dengue virus

被引:22
|
作者
Weng, Chen-Hsun [4 ]
Huang, Tze-Bin [2 ]
Huang, Chih-Chia [3 ]
Yeh, Chen-Sheng [3 ]
Lei, Huan-Yao [4 ]
Lee, Gwo-Bin [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Power Mech Engn, Hsinchu 30013, Taiwan
[2] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 701, Taiwan
[3] Natl Cheng Kung Univ, Dept Chem, Tainan 701, Taiwan
[4] Natl Cheng Kung Univ, Dept Microbiol & Immunol, Tainan 701, Taiwan
关键词
Microfluidics; Suction; Immunosensing; ELISA; Dengue virus; Surface modification; MICROCHIP ELECTROPHORESIS; SURFACE MODIFICATION; PROTEIN NS1; ASSAY; CHANNELS; ANTIBODY; ELISA; FLOW;
D O I
10.1007/s10544-011-9529-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The enzyme-linked immunosorbent assay (ELISA) is widely used in medical diagnostics. In order to reduce the diagnosis time and to lower the consumption of sample/reagents in an ELISA assay, a suction-type, automatic, pneumatically-driven microfluidic chip has been designed and fabricated in this study. The microfluidic chip integrates a multi-functional micro-transport/mixing unit, for transporting metering and mixing of samples and reagents in order to automatically perform the entire ELISA protocol. A new surface modification has been adopted which allows for a high processing capacity. The detection sensitivity for the dengue virus is found to be 10(1) PFU/ml, which is much better than a conventional ELISA assay (10(3) PFU/ml). The entire assay time is only 30 min, which is much faster than with 96-well microtiter plates (4 h). The consumed sample and reagent volume is only 12 mu l, which is less than a conventional assay (100 mu l). The development of this microfluidic chip may be promising for other immunosensing applications.
引用
收藏
页码:585 / 595
页数:11
相关论文
共 50 条
  • [21] Rapid detection for primary screening of influenza A virus: microfluidic RT-PCR chip and electrochemical DNA sensor
    Yamanaka, Keiichiro
    Saito, Masato
    Kondoh, Kenji
    Hossain, Mohammad Mosharraf
    Koketsu, Ritsuko
    Sasaki, Tadahiro
    Nagatani, Naoki
    Ikuta, Kazuyoshi
    Tamiya, Eiichi
    ANALYST, 2011, 136 (10) : 2064 - 2068
  • [22] Rapid detection of formaldehyde concentration in food on a polydimethylsiloxane (PDMS) microfluidic chip
    Weng, Xuan
    Chon, Chan Hee
    Jiang, Hai
    Li, Dongqing
    FOOD CHEMISTRY, 2009, 114 (03) : 1079 - 1082
  • [23] Rapid glucose concentration detection utilizing disposable integrated microfluidic chip
    Hui-Hsiung Hou
    Yao-Nan Wang
    Chin-Lung Chang
    Ruey-Jen Yang
    Lung-Ming Fu
    Microfluidics and Nanofluidics, 2011, 11 : 479 - 487
  • [24] Rapid glucose concentration detection utilizing disposable integrated microfluidic chip
    Hou, Hui-Hsiung
    Wang, Yao-Nan
    Chang, Chin-Lung
    Yang, Ruey-Jen
    Fu, Lung-Ming
    MICROFLUIDICS AND NANOFLUIDICS, 2011, 11 (04) : 479 - 487
  • [25] Rapid Sub-attomole MicroRNA Detection on a Portable Microfluidic Chip
    Arata, Hideyuki
    Hosokawa, Kazuo
    Maeda, Mizuo
    ANALYTICAL SCIENCES, 2014, 30 (01) : 129 - 135
  • [26] Rapid Sub-attomole MicroRNA Detection on a Portable Microfluidic Chip
    Hideyuki Arata
    Kazuo Hosokawa
    Mizuo Maeda
    Analytical Sciences, 2014, 30 : 129 - 135
  • [27] OPTOFLUIDIC SURFACE ENHANCED RAMAN SCATTERING CHIP FOR DETECTION OF DENGUE VIRUS
    Huh, Yun Suk
    Chung, Aram J.
    Cordovez, Bernardo
    Erickson, David
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 13, PTS A AND B, 2009, : 873 - 876
  • [28] STUDIES ON THE RAPID DETECTION OF DENGUE VIRUS ANTIGEN BY IMMUNOFLUORESCENCE AND RADIOIMMUNOASSAY
    丘福禧
    张浩燕
    邵兰
    李雪东
    罗惠蓉
    余永新
    CHINESEMEDICALJOURNAL, 1981, (10)
  • [29] STUDIES ON THE RAPID DETECTION OF DENGUE VIRUS ANTIGEN BY IMMUNOFLUORESCENCE AND RADIOIMMUNOASSAY
    丘福禧
    张浩燕
    邵兰
    李雪东
    罗惠蓉
    余永新
    中华医学杂志(英文版), 1981, (10) : 653 - 658
  • [30] Biosensor for Dengue virus detection: Sensitive, rapid, and serotype specific
    Baeumner, AJ
    Schlesinger, NA
    Slutzki, NS
    Romano, J
    Lee, EM
    Montagna, RA
    ANALYTICAL CHEMISTRY, 2002, 74 (06) : 1442 - 1448