Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

被引:31
|
作者
Iffa, Emishaw [1 ]
Hun, Diana [1 ]
Salonvaara, Mikael [1 ]
Shrestha, Som [1 ]
Lapsa, Melissa [2 ]
机构
[1] Oak Ridge Natl Lab, Bldg Envelope Mat Res Grp, Bldg & Transportat Sci, Oak Ridge, TN 37830 USA
[2] Oak Ridge Natl Lab, Energy Sci & Technol Directorate, Bldg Technol Program, Oak Ridge, TN USA
关键词
Active insulation system; Convective water loop; Cooling load; Heat flux; Hydronic system; Peak-load; Thermal energy storage; EMBEDDED BUILDING ENVELOPE; COOLING SYSTEMS; EFFICIENCY; WATER; SIMULATION; COMFORT; CLIMATE; SAVINGS;
D O I
10.1016/j.est.2021.103815
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The per-formances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m(2). The active insulation system's dynamic R-value varied between less than 1ft2 center dot degrees F.h/BTU (0.18 m(2).K/W) to 98% of the equally thick foam insulation's R-value.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Optimization of integrated energy systems considering seasonal thermal energy storage
    Zhou, Yixing
    Min, Chunhua
    Wang, Kun
    Xie, Liyao
    Fan, Yuanhong
    JOURNAL OF ENERGY STORAGE, 2023, 71
  • [42] Dynamic Model of a Refrigeration System with Active Thermal Energy Storage
    Fasl, Joseph M.
    Briscoe, Casey R.
    Mohs, William F.
    Alleyne, Andrew G.
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 1, 2014, 120
  • [43] ANALYSIS OF RENEWABLE ENERGY INTEGRATED PUMPED THERMAL ENERGY STORAGE SYSTEMS
    Desai, Nishith B.
    Parisi, Simone
    Remygiakis, Nikolaos
    Haglind, Fredrik
    PROCEEDINGS OF ASME 2023 17TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, ES2023, 2023,
  • [44] Thermal Insulation Performance of the Thermal Insulation Material of the Exterior Wall of the Port Building
    Guo, Xiaochen
    JOURNAL OF COASTAL RESEARCH, 2019, : 341 - 347
  • [45] Energy performance of dynamic thermal insulation built in the experimental facade system
    Wieprzkowicz, Anna
    Heim, Dariusz
    MANAGEMENT OF ENVIRONMENTAL QUALITY, 2016, 27 (06) : 681 - 694
  • [46] Preparation and Performance of Thermal Insulation Energy Saving Coating Materials for Exterior Wall
    Wang, Fei
    Liang, Jinsheng
    Tang, Qingguo
    Chen, Cong
    Chen, Yalei
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2014, 14 (05) : 3861 - 3867
  • [47] Building energy conservation and wall thermal insulation
    China Xinxing Build and Develop Company, Beijing 100039, China
    Gongcheng Lixue, 2006, SUPPL. 2 (167-184):
  • [48] Study on thermal performance of dynamic insulation roof integrated with phase change material
    Yu, Jinghua
    Yang, Hongyun
    Zhao, Jingang
    Zhang, Chong
    Qian, Congcong
    Chen, Yanhua
    Tang, Xiaoliang
    ENERGY AND BUILDINGS, 2024, 303
  • [49] Development of internal thermal system for rc wall using vacuum insulation panel and its evaluation of thermal insulation performance
    Hayakawa N.
    Yokoe A.
    AIJ Journal of Technology and Design, 2019, 25 (61): : 1161 - 1165
  • [50] Peak cooling load shift capability of a thermal energy storage system integrated with an active insulation system in US climate zones
    Jung, Sungkyun
    Yoon, Yeobeom
    Im, Piljae
    Salonvaara, Mikael
    Dong, Jin
    Cui, Borui
    Lapsa, Melissa
    ENERGY AND BUILDINGS, 2022, 277