Detection of dopamine in non-treated urine samples using glassy carbon electrodes modified with PAMAM dendrimer-Pt composites

被引:19
|
作者
Garcia, M. G. [1 ,2 ]
Armendariz, G. M. E. [1 ]
Godinez, Luis A. [1 ]
Torres, J. [1 ]
Sepulveda-Guzman, S. [3 ]
Bustos, E. [1 ]
机构
[1] Ctr Invest & Desarrollo Tecnol Electroquim SC, Lab Bioelectrochem, Pedro Escobedo 76703, Queretaro, Mexico
[2] Univ Guanajuato, Dept Chem, Guanajuato 36040, Gto, Mexico
[3] Univ Autonoma Nuevo Leon, Fac Ingn Mecan & Elect, Ctr Innovac Invest & Desarrollo Ingn & Tecnol, Nuevo Leon 66451, Mexico
关键词
Dopamine; FIA; DENs-Pt; Urine; ASSEMBLING GOLD NANOPARTICLES; NANOCOMPOSITES; NANOCLUSTERS; REDUCTION; BIOSENSOR; SURFACE; CONSTRUCT; SIZE;
D O I
10.1016/j.electacta.2011.06.035
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Composites of hydroxyl-terminated PAMAM dendrimers, generation 4.0 (64 peripheral OH groups) containing Pt nanoparticles were synthesized at different reaction times using a microwave reactor. The synthetic procedure resulted in dendrimer encapsulated nanoparticles of Pt (DENs-Pt) of 1.53 +/- 0.17 nm diameter that was calculated from transmission electron microscopy, and the Pt nanoparticles had single crystal plane in (1 1 1) orientation determinate by selective area diffraction. Each composite was electrochemically immobilized on a pre-functionalized glassy carbon (GC) electrode that was incorporated as a flow injection amperometric (FIA) detector, for the selective detection and quantification of dopamine (DA) in untreated urine samples. Comparison of the analytical performance of the novel electrochemical detector revealed that the DENs-Pt modified GC electrode with the composite synthesized for 30 min in the microwave reactor, showed the best response for the detection of DA in samples of non-treated urine, being the detection and quantification limits smaller (19 and 9 ppb, respectively) than those corresponding to the naked a GC electrode (846 and 423 ppb, respectively) using the FIA detector. In addition, it was found that this electroanalytical approach suffers minimal matrix effects that arise in the analysis of DA in untreated samples of urine. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:7712 / 7717
页数:6
相关论文
共 50 条
  • [21] Impedance and voltammetry detection of bromate in food samples using NiPcMWCNTs modified glassy carbon electrode
    Sheriff Aweda Balogun
    Omolola Esther Fayemi
    Journal of Analytical Science and Technology, 14
  • [22] Impedance and voltammetry detection of bromate in food samples using NiPcMWCNTs modified glassy carbon electrode
    Balogun, Sheriff Aweda
    Fayemi, Omolola Esther
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2023, 14 (01)
  • [23] Simultaneous and selective determination of purine metabolites in human urine samples using nanocomposite modified glassy carbon electrode
    Liu, Xiaojian
    Dai, Jindong
    Shen, Jian
    Zhu, Dongwei
    Rajalakshmi, Kanagaraj
    Muthusamy, Selvaraj
    Kanagaraj, Thangamani
    Kannan, Palanisamy
    JOURNAL OF MOLECULAR LIQUIDS, 2024, 411
  • [24] Selective Determination of Norfloxacin in Pharmaceutical Formulations and Human Urine Samples Using Poly(8-aminonaphthaline-2-sulfonic Acid)-Modified Glassy Carbon Electrodes
    Debalkie, Ameha
    Guadie, Atnafu
    Kassa, Adane
    Tefera, Molla
    ACS OMEGA, 2023, 8 (29): : 25758 - 25765
  • [25] A ratiometric electrochemical probe for the quantification of apixaban in unprocessed plasma samples using carbon aerogel/BFO modified glassy carbon electrodes
    Shahbazi-Derakhshi, Payam
    Abbasi, Mohammad
    Akbarzadeh, Amirhossein
    Mokhtarzadeh, Ahad
    Hosseinpour, Hamid
    Soleymani, Jafar
    RSC ADVANCES, 2023, 13 (31) : 21432 - 21440
  • [26] Nanomolar Detection of Vitamin C in Artificial Urine using a Glassy Carbon Electrode Modified with Molybdenum Disulfide
    Sampathkumar, Prakasam
    Sudalaimani, Sudalaimuthu
    Giribabu, Krishnan
    Suresh, Chinnathambi
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (08)
  • [27] Enhancing Dopamine Detection Using Glassy Carbon Electrode Modified with Graphene Oxide, Nickel and Gold Nanoparticles
    Hassine, Chedia Ben Ali
    Kahri, Hamza
    Barhoumi, Houcine
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)
  • [28] Simultaneous voltammetry detection of dopamine and uric acid in human serum and urine with a poly(procaterol hydrochloride) modified glassy carbon electrode
    Kong, Dexian
    Zhuang, Qizhao
    Han, Yejian
    Xu, Lanping
    Wang, Zeming
    Jiang, Lili
    Su, Jinwei
    Lu, Chun-Hua
    Chi, Yuwu
    TALANTA, 2018, 185 : 203 - 212
  • [29] Sensitive and Selective Detection of Multiple Metal Ions Using Amino Acids Modified Glassy Carbon Electrodes
    Nisar, Anum
    Shah, Afzal
    Zahid, Anum
    Iftikhar, Faiza Jan
    Hassan, Abbas
    Shah, Aamir Hassan
    She, Zhe
    Akhter, Mohammad Salim
    Piro, Benoit
    Kraatz, Heinz-Bernhard
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (03) : B67 - B73
  • [30] Electrochemical detection of mercury using biosynthesized hydroxyapatite nanoparticles modified glassy carbon electrodes without preconcentration
    Kanchana, P.
    Sudhan, N.
    Anandhakumar, S.
    Mathiyarasu, J.
    Manisankar, P.
    Sekar, C.
    RSC ADVANCES, 2015, 5 (84): : 68587 - 68594