On the Feasibility of Quantifying Fibrous Cap Thickness With Acoustic Radiation Force Impulse (ARFI) Ultrasound

被引:13
|
作者
Czernuszewicz, Tomasz J. [1 ,2 ]
Gallippi, Caterina M. [1 ,3 ]
机构
[1] Univ N Carolina, Joint Dept Biomed Engn, Chapel Hill, NC 27599 USA
[2] North Carolina State Univ, Raleigh, NC 27607 USA
[3] North Carolina State Univ, Dept Elect & Comp Engn, Raleigh, NC 27607 USA
关键词
Acoustic radiation force; acoustic radiation force impulse (ARFI); atherosclerosis; fibrous cap (FC); finite-element method (FEM); resolution; vulnerable plaque; NONINVASIVE MATERIAL CHARACTERIZATION; SYMPTOMATIC CAROTID PLAQUES; IN-VIVO; TISSUE-RESPONSE; CORE THICKNESS; RESOLUTION; MRI; ENDARTERECTOMY; DISPLACEMENTS; TRACKING;
D O I
10.1109/TUFFC.2016.2535440
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Acute cerebrovascular accidents are associated with the rupture of vulnerable atherosclerotic plaques in the carotid arteries. Fibrous cap (FC) thickness has been shown to be an important predictor of plaque rupture but has been challenging to measure accurately with clinical noninvasive imaging modalities. The goals of this investigation were first, to evaluate the feasibility of using transcutaneous acoustic radiation force impulse (ARFI) ultrasound to quantify FC thickness and second, to optimize both imaging and motion-tracking parameters to support such measurements. FCs with varying thickness (0.1-1.0 mm) were simulated using a simple-layered geometry, and their mechanical response to an impulse of radiation force was solved using finite-element method (FEM) modeling. Ultrasound tracking of FEM displacements was performed in Field II utilizing three center frequencies (6, 9, and 12 MHz) and eight motion-tracking kernel lengths (0.5 lambda - 4 lambda). Additionally, FC thickness in two carotid plaques imaged in vivo was measured with ARFI and compared to matched histology. The results of this study demonstrate that 1) tracking pulse frequencies around 12 MHz are necessary to resolve caps around 0.2 mm; 2) large motion-tracking kernel sizes introduce bias into thickness measurements and overestimate the true cap thickness; and 3) color saturation settings on ARFI peak displacement images can impact thickness measurement accuracy substantially.
引用
收藏
页码:1262 / 1275
页数:14
相关论文
共 50 条
  • [31] Clinical Feasibility of 3-D Acoustic Radiation Force Impulse (ARFI) Imaging for Targeted Prostate Biopsy Guidance
    Chan, Derek Y.
    Moavenzadeh, Spencer R.
    Wightman, Wren E.
    Palmeri, Mark L.
    Polascik, Thomas J.
    Nightingale, Kathryn R.
    ULTRASONIC IMAGING, 2025, 47 (02) : 79 - 92
  • [32] Quantitative assessment of muscular stiffness in children with cerebral palsy using acoustic radiation force impulse (ARFI) ultrasound elastography
    Bilgici, Meltem Ceyhan
    Bekci, Tumay
    Ulus, Yasemin
    Ozyurek, Hamit
    Aydin, Omer Faruk
    Tomak, Leman
    Selcuk, Mustafa Bekir
    JOURNAL OF MEDICAL ULTRASONICS, 2018, 45 (02) : 295 - 300
  • [33] Evaluation of Ultrasound Based Acoustic Radiation Force Impulse (ARFI) and eSie touch Sonoelastography for Diagnosis of Inflammatory Pancreatic Diseases
    Mateen, Mohammad A.
    Muheet, Khan A.
    Mohan, Ramchandani J.
    Rao, Poplapally N.
    Majaz, Hussain M. K.
    Rao, Guduru V.
    Reddy, Duvvur N.
    JOURNAL OF THE PANCREAS, 2012, 13 (01): : 36 - 44
  • [34] Acoustic Radiation Force Impulse (ARFI) and High-Frequency Ultrasound of the Liver Surface for the Diagnosis of Compensated Liver Cirrhosis
    Pfeifer, L.
    Goertz, R. S.
    Sturm, J.
    Wachter, D.
    Riener, M. O.
    Schwitulla, J.
    Bernatik, T.
    Neurath, M. F.
    Strobel, D.
    ULTRASCHALL IN DER MEDIZIN, 2014, 35 (01): : 44 - 50
  • [35] Quantitative assessment of muscular stiffness in children with cerebral palsy using acoustic radiation force impulse (ARFI) ultrasound elastography
    Meltem Ceyhan Bilgici
    Tumay Bekci
    Yasemin Ulus
    Hamit Ozyurek
    Omer Faruk Aydin
    Leman Tomak
    Mustafa Bekir Selcuk
    Journal of Medical Ultrasonics, 2018, 45 : 295 - 300
  • [36] THE VALUE OF ACOUSTIC RADIATION FORCE IMPULSE ELASTOGRAPHY (ARFI) FRO THE EVALUATION OF LIVER FIBROSIS
    Sporea, I.
    Sirli, R.
    Popescu, A.
    Danila, M.
    Bota, S.
    JOURNAL OF HEPATOLOGY, 2010, 52 : S173 - S173
  • [37] Factors that influence the correlation of Acoustic Radiation Force Impulse (ARFI) elastography with liver fibrosis
    Bota, Simona
    Sporea, Ioan
    Sirli, Roxana
    Popescu, Alina
    Danila, Mirela
    Sendroiu, Madalina
    MEDICAL ULTRASONOGRAPHY, 2011, 13 (02) : 135 - 140
  • [38] Acoustic radiation force impulse (ARFI) elastography of testicular disorders in dogs: preliminary results
    Feliciano, M. A. R.
    Maronezi, M. C.
    Simoes, A. P. R.
    Maciel, G. S.
    Pavan, L.
    Gasser, B.
    Silva, P.
    Uscategui, R. R.
    Carvalho, C. F.
    Canola, J. C.
    Vicente, W. R. R.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2016, 68 (02) : 283 - 291
  • [39] Evaluation of Neonatal Brain Development Using Acoustic Radiation Force Impulse Imaging (ARFI)
    Su, Y.
    Ma, J.
    Du, L. F.
    Xia, J.
    Wu, Y.
    Jia, X.
    Cai, Y. G.
    Li, Y. H.
    Zhao, J.
    Liu, Q.
    NEUROPHYSIOLOGY, 2015, 47 (04) : 322 - 325
  • [40] Noninvasive Assessment of Liver Fibrosis Using Acoustic Radiation Force Impulse (ARFI) Imaging
    Bajwa, A.
    Wood, C.
    Berggruen, S.
    Miller, F.
    Ganger, D.
    Grant, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)