A novel dual-wavelength iterative method for generalized dual-wavelength phase-shifting interferometry with second-order harmonics

被引:12
|
作者
Xu, Xiaoqing [1 ,3 ]
Wang, Yawei [2 ]
Ji, Ying [2 ]
Xu, Yuanyuan [2 ]
Xie, Ming [2 ]
Han, Hao [2 ]
机构
[1] Jiangsu Univ, Sch Mech Engn, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Jiangsu Univ, Fac Sci, Zhenjiang 212013, Jiangsu, Peoples R China
[3] Yangzhou Polytech Coll, Sch Mech Engn, Yangzhou 225009, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Interferometry; Fringe analysis; Phase measurement; Biological cells; REFRACTIVE-INDEX; RETRIEVAL METHOD; HOLOGRAPHY; ALGORITHM; CELLS;
D O I
10.1016/j.optlaseng.2018.02.007
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To address dual-wavelength interferograms with arbitrary phase shifts and second-order harmonics, a novel dual wavelength iterative method (DWIM) based on the least-squares algorithm is proposed. In generalized dual wavelength phase-shifting interferometry, to compensate for the phase-shift errors consisting of systematic and random phase-shift error, the wrapped phases of single-wavelength with high accuracy can be simultaneously obtained from generalized dual-wavelength interferograms without second-order harmonics. In addition, this method is also employed to deal with randomly phase-shifted dual-wavelength interferograms with the second order harmonics, and then the effects of the fringe number in interferogram and the number of interferograms used on the accuracy of phase extraction are investigated by numerical simulations. Based on theoretical analysis and simulation results of DWIM, we present the basic relationship between the number of wavelengths, the second order harmonics and the requirement of the minimum number of interferograms. Finally, the effectiveness of this method is proved by the simulation results of the spherical cap, and its applicability is verified with the results of the micro-sphere, the HeLa cell and the red blood cell, respectively. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 50 条
  • [41] Digital holographic microscopy with dual-wavelength phase unwrapping
    Parshall, D
    Kim, MK
    [J]. APPLIED OPTICS, 2006, 45 (03) : 451 - 459
  • [42] Treatment of acne scarring with a novel dual-wavelength laser
    Gold, Michael H.
    Wilson, April
    Mordon, Serge R.
    [J]. JOURNAL OF COSMETIC DERMATOLOGY, 2019, 18 (05) : 1290 - 1293
  • [43] TREATMENT OF ACNE SCARRING WITH A NOVEL DUAL-WAVELENGTH LASER
    Gold, Michael H.
    Mordon, Serge R.
    [J]. LASERS IN SURGERY AND MEDICINE, 2018, 50 : S22 - S22
  • [44] A dual-wavelength radar method to measure snowfall rate
    Matrosov, SY
    [J]. JOURNAL OF APPLIED METEOROLOGY, 1998, 37 (11): : 1510 - 1521
  • [45] Dual-wavelength method brings zoom capability to microendoscopy
    Overton, Gail
    [J]. LASER FOCUS WORLD, 2012, 48 (08): : 19 - 20
  • [46] Photoacoustic temperature measurement based on dual-wavelength method
    Liao Yu
    Jian Xiao-Hua
    Cui Yao-Yao
    Zhang Qi
    [J]. ACTA PHYSICA SINICA, 2017, 66 (11)
  • [47] AN IMPROVED METHOD OF ISOMOLAR SERIES BY DUAL-WAVELENGTH SPECTROPHOTOMETRY
    ZHOU, N
    HE, CX
    [J]. MIKROCHIMICA ACTA, 1993, 111 (4-6): : 183 - 191
  • [48] Digital hologram reconstruction using the dual-wavelength method
    Kim, J
    Kim, N
    [J]. PRACTICAL HOLOGRAPHY XVII AND HOLOGRAPHIC MATERIALS IX, 2003, 5005 : 238 - 246
  • [49] Dual-wavelength method for measuring the thickness of HSQ photoresist
    Yao Shun
    Yu Bo
    Jin Jingcheng
    Li Chun
    [J]. 8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2016, 9684
  • [50] DUAL-WAVELENGTH SPECTROPHOTOMETRY .I. GENERAL METHOD
    SHIBATA, S
    FURUKAWA, M
    GOTO, K
    [J]. ANALYTICA CHIMICA ACTA, 1969, 46 (02) : 271 - &