Electric field in Ns pulse and AC electric discharges in a hydrogen diffusion flame

被引:27
|
作者
Simeni, Marien Simeni [1 ]
Tang, Yong [2 ]
Hung, Yi-Chen [1 ]
Eckert, Zakari [1 ]
Frederickson, Kraig [1 ]
Adamovich, Igor, V [1 ]
机构
[1] Ohio State Univ, Dept Mech & Aerosp Engn, Nonequilibrium Thermodynam Lab, Columbus, OH 43210 USA
[2] Tsinghua Univ, Dept Energy & Power Engn, Minist Educ, Key Lab Thermal Sci & Power Engn, Beijing 100084, Peoples R China
关键词
Electric field; Second harmonic generation; Diffusion flame; ns pulse discharge; Plasma-assisted combustion; Ion wind; DIELECTRIC-BARRIER-DISCHARGE; PLASMA; TEMPERATURE; DETACHMENT; ATTACHMENT; IONS; O2;
D O I
10.1016/j.combustflame.2018.08.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
Time-resolved electric field is measured in ns pulse and AC sine wave dielectric barrier discharges sustained in an atmospheric pressure hydrogen diffusion flame, using picosecond second harmonic generation. Individual electric field vector components are isolated by measuring the second harmonic signals with different polarizations. Electric field measurements in a ns pulse discharge are self-calibrating, since the field follows the applied voltage until breakdown. Electric field is measured in a ns pulse discharge sustained both in the hydrogen flow below the flame and in the reaction zone of the flame. Peak electric field in the reaction zone is lower compared to that in the near-room temperature hydrogen flow, due to a significantly lower number density. In hydrogen, most of the energy is coupled to the plasma at the reduced electric field of E/N approximate to 50-100 Td. In both cases, the electric field decreases to near zero after breakdown, due to plasma self-shielding. The time scale for the electric field reduction in the plasma is relatively long, several tens of ns, indicating that it may be controlled by a relatively slow propagation of the ionization wave over the dielectric surfaces. In the AC discharge, the electric field is put on the absolute scale by measuring a Laplacian electric field between two parallel cylinder electrodes. The measurement results demonstrate that a strong electric field in the plasma-enhanced flame is produced during the entire AC voltage period, without correlation with the random micro-discharges detected in the plasma images. The measurement results indicate consistently higher peak electric field during the negative AC half-period, as well as a significant electric field offset. Both the asymmetry and the offset of the electric field are likely responsible for the ion wind resulting in the flame distortion. The results suggest that at the present conditions the ion wind is dominated by the transport of negative ions generated in the ambient air plasma near the flame. The results demonstrate a significant potential of ps second harmonic generation diagnostics for non-intrusive measurements of the electric field in atmospheric pressure flames enhanced by electric discharge plasmas. (C) 2018 Published by Elsevier Inc. on behalf of The Combustion Institute.
引用
收藏
页码:254 / 264
页数:11
相关论文
共 50 条
  • [21] AC electric field induced vortex in laminar coflow diffusion flames
    Xiong, Yuan
    Cha, Min Suk
    Chung, Suk Ho
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2015, 35 : 3513 - 3520
  • [22] REQUIREMENTS FOR STABLE AC ELECTRIC-ARC DISCHARGES
    LUXAT, JC
    LEES, LH
    ELECTRONICS LETTERS, 1970, 6 (09) : 285 - &
  • [23] ON THE MODIFICATION OF THE STARK STATES OF HYDROGEN BY A WEAK AC ELECTRIC-FIELD
    FLORESCU, V
    PATRASCU, S
    JOURNAL OF MATHEMATICAL PHYSICS, 1990, 31 (09) : 2165 - 2169
  • [24] Electric field in an AC dielectric barrier discharge overlapped with a nanosecond pulse discharge
    Goldberg, Benjamin M.
    Shkurenkov, Ivan
    Adamovich, Igor V.
    Lempert, Walter R.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2016, 25 (04):
  • [25] Electric field measurements in nanosecond pulse discharges in air over liquid water surface
    Simeni, Marien Simeni
    Baratte, Edmond
    Zhang, Cheng
    Frederickson, Kraig
    Adamovich, Igor V.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2018, 27 (01):
  • [26] Electric fatigue of ferroelectric ceramics under AC electric field
    Chen, ZW
    Zhang, Y
    RARE METAL MATERIALS AND ENGINEERING, 2005, 34 (07) : 1109 - 1113
  • [27] Electric field influence on the stability and the soot particles emission of a laminar diffusion flame
    Gillon, Pascale
    Gilard, Virginie
    Idir, Mahmoud
    Sarh, Brahim
    COMBUSTION SCIENCE AND TECHNOLOGY, 2019, 191 (02) : 325 - 338
  • [28] TEMPERATURE PROFILES OF AN OPPOSED-JET DIFFUSION FLAME SUBJECTED TO AN ELECTRIC FIELD
    HEINSOHN, RJ
    THILLARD, SV
    BECKER, PM
    COMBUSTION AND FLAME, 1969, 13 (04) : 442 - &
  • [29] Pulse electric discharges and prolonged microbial resistance of water
    Kolikov V.A.
    Kurochkin V.E.
    Panina L.K.
    Rutberg F.G.
    Doklady Biological Sciences, 2005, 403 (1-6) : 279 - 281
  • [30] Electric field effect on the diffusion flame structure at different oxidizer excess coefficients
    Reshetnikov S.M.
    Bobrov A.S.
    Zyryanov I.A.
    Russian Aeronautics (Iz VUZ), 2010, 53 (2) : 206 - 211