Analysis of Resonance Influence of Capacitor Voltage Transformer and Protective Measures

被引:0
|
作者
Yang, Xuefei [1 ]
Li, Ying Hong [1 ]
Liu, Bin [1 ]
机构
[1] China Southern Power Grid EHV Power Transmiss Co, Liuzhou Bur, 22 Haiguan Rd, Liuzhou, Guangxi, Peoples R China
关键词
Capacitor voltage transformers; resonance mechanism; fault characteristics; cause of detuning; Protective measures;
D O I
10.1117/12.2592250
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In view of the frequent occurrence of abnormal voltage of capacitive voltage transformer in the power grid, this article has deeply studied the application of resonance mechanism in capacitive voltage transformer and the analysis of fault influence, combined with the case, the phenomenon and characteristics of the detuning failure of the compensating reactance series resonance and the resonant damper parallel resonance are analyzed. The reasons and characteristics of the two resonant circuit failures are summarized for the reference of field technicians. Finally, this article puts forward effective protective measures for the operation and maintenance of capacitor voltage transformers.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Broadband passive circuit model of capacitor voltage transformer
    Liang G.
    Du X.
    Xie Y.
    Jing Y.
    Du, Xinyu (dujianing_djn@163.com), 1600, Science Press (42): : 179 - 185
  • [22] Experimental study on the influence of series compensation platform switching on capacitor voltage transformer in ultra high voltage power system
    Li, Jinyu
    Ji, Shengchang
    Zhu, Lingyu
    Wang, Shaowu
    Chen, Guoqiang
    Yin, Yu
    Shi, Weidong
    Kang, Peng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (07): : 1799 - 1807
  • [23] Analysis of the Charging Characteristics of High Voltage Capacitor Chargers Considering the Transformer Stray Capacitance
    Lee, Byangha
    Cha, Hanju
    JOURNAL OF POWER ELECTRONICS, 2013, 13 (03) : 329 - 338
  • [24] Online metering performance evaluation of capacitor voltage transformer based on principal component analysis
    Han H.
    Zhang Z.
    Wang H.
    Li H.
    Xue J.
    Shao L.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (05): : 201 - 206
  • [25] Influences of circuit parameters of capacitor voltage transformer on grid harmonic voltage measurements
    Feng, Yu, 1600, Chinese Society for Electrical Engineering (34):
  • [26] Investigation of 150 kV Capacitor Voltage Transformer Breakdown During Capacitor Bank Switching
    Kusuma, Aristo Adi
    Pramana, Putu Agus Aditya
    Munir, Buyung Sofiarto
    2017 7TH INTERNATIONAL ANNUAL ENGINEERING SEMINAR (INAES), 2017, : 168 - 171
  • [27] Performance assessment of distance protection fed by capacitor voltage transformer with electronic ferro-resonance suppression circuit
    Venkatesh, C.
    Swarup, K. Shanti
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 112 : 12 - 19
  • [28] Resonance Voltage System for Capacitor Testing.
    Hajek, Milos
    Elektrotechnicky obzor, 1988, 77 (05): : 263 - 267
  • [29] EFFICIENT VOLTAGE CONVERTER FOR A TANK CAPACITOR BASED ON A PIEZOELECTRIC TRANSFORMER
    IZYUROVA, GI
    SOROKIN, AA
    SPIRIN, YL
    FROLOV, VN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1984, 27 (01) : 113 - 114
  • [30] Thermal Modeling of a Capacitor Voltage Transformer Using CFD Techniques
    Silva, R. G.
    Brito Filho, J. P.
    Lira, J. C., Jr.
    Henriquez, J. R.
    IEEE LATIN AMERICA TRANSACTIONS, 2018, 16 (08) : 2234 - 2239