Thermal control of a mechanically pumped two-phase loop

被引:11
|
作者
Li, Guanru [1 ]
Jiang, Haitao [2 ]
Zheng, Yi [1 ]
Zhang, Chengbin [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Key Lab Energy Thermal Convers & Control, Minist Educ, Nanjing 210096, Peoples R China
[2] 38th Res Inst China Elect Technol Corp, Hefei 230088, Peoples R China
基金
国家重点研发计划;
关键词
Minichannel evaporator; Two-phase loop; Temperature control; Feed-forward compensation; Model predictive control; CAPILLARY-DRIVEN; FLOW-CONTROL; HEAT-PIPE; PERFORMANCE; THERMOSIPHON;
D O I
10.1016/j.icheatmasstransfer.2022.106365
中图分类号
O414.1 [热力学];
学科分类号
摘要
With integration and miniaturization of electronic devices, the heat dissipation has grown exponentially, necessitating feasible thermal management systems and cooling alternatives. Among them, two-phase loop cooling is deemed to be highly effective, in which the minichannel evaporator is rendered as a mechanically pumped two-phase loop (MPTL), ensuring the precise thermal control. Herein, the temperature control accuracy of MPTL has been particularly emphasized by proposing the feed-forward offset-free model predictive controller (MPC), and compared with the PI controller that has also been structurally modified (namely, improved PI controller). MPC is designed, optimized and tuned based on the unsteady-state nonlinear analysis, addressing the challenges, such as frequent heat load fluctuations and various nonlinearities/uncertainties mainly encountered during the minichannel boiling. Results depict the superiority of MPC in terms of shorter transient time (measured by set-point tracking), higher temperature control accuracy and lower absolute error (IAE) index (both determined by disturbance rejection), mitigating the effect of flow-boiling uncertainties. Especially, the average transient time of MPC on MPTL has been found at least four times shorter than that of the improved PI controller. Also, IAE index of MPC on MPTL is better than that of the improved PI controller. Meanwhile, the temperature control accuracy of MPC on MPTL during disturbance suppression is as little as 0.2 degrees C, while that of the improved PI is higher (1.1 degrees C). The temperature control of the proposed controller (MPC) is therefore satisfactory based on which it can be engaged in MPTL technology for further development of electronic applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] SIMULATION AND VALIDATION OF A TWO-PHASE PUMPED LOOP COOLING SYSTEM
    Magee, Thomas C.
    Hines, Kristen M.
    Dumesh, Mike A.
    Meekins, Andrew D.
    Bridges, Michael M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 8, 2019,
  • [32] Design and performance of a mechanically pumped two-phase loop to support the evaporation-condensation experiments on the TZ1
    Wang, Z. R.
    Zhang, X. B.
    Wen, S. Z.
    Huang, Z. C.
    Mo, D. C.
    Xue, Y. Q.
    He, Z. H.
    CASE STUDIES IN THERMAL ENGINEERING, 2017, 10 : 650 - 655
  • [33] Development status of the mechanically pumped two-phase CO2 cooling loop for the AMS-2 TTCS
    Delil, AAM
    Woering, AA
    Verlaat, B
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM - STAIF 2003, 2003, 654 : 88 - 95
  • [34] Study on the flow boiling characteristics of novel pin fin heat sinks in a two-phase mechanically pumped cooling loop
    Wang, Jiale
    Qi, Shaohuan
    Xu, Zhaohao
    Xu, Yu
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 60
  • [35] Studies of a Mechanically Pumped Two-Phase Loop with a Pressure-Controlled Accumulator Under Pulsed Evaporator Heat Loads
    Truster, Nicholas
    Ervin, Jamie S.
    Roman, Abdeel
    Monfort, Jeff
    ENERGIES, 2024, 17 (24)
  • [36] Experimental and analytical study of a reversible two-phase capillary pumped loop
    Hustaix, H
    Maciaszek, T
    Puillet, C
    SIXTH EUROPEAN SYMPOSIUM ON SPACE ENVIRONMENTAL CONTROL SYSTEMS, VOLS 1 AND 2, 1997, 400 : 411 - 417
  • [37] Feasibility demonstration of a mechanically pumped two-phase CO2 cooling loop for the AMS-2 tracker experiment
    Verlaat, B
    Rookhuizen, HB
    Delil, AAM
    Woering, AA
    Perrin, E
    Pohl, M
    Battiston, R
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM-STAIF 2002, 2002, 608 : 57 - 64
  • [38] Comparison between acetone and ammonia on the thermal performance of a small-scale capillary pumped two-phase loop
    Riehl, RR
    Bazzo, E
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM - STAIF 2003, 2003, 654 : 80 - 87
  • [39] Numerical and Experimental Investigation of Heat Transfer in the Porous Media of an Additively Manufactured Evaporator of a Two-Phase Mechanically Pumped Loop for Space Applications
    Valdarno, Luca
    Dhir, Vijay K.
    Furst, Benjamin
    Sunada, Eric
    MICROGRAVITY SCIENCE AND TECHNOLOGY, 2024, 36 (04)
  • [40] Pressure spike and its suppression in the two phase CO2 mechanically pumped thermal control system
    Huang, Zhen-Cheng
    Xiao, Wen-Jia
    Sun, Xi-Hui
    Pan, Zhi-Wen
    Guo, Kai-Hua
    He, Zhen-Hui
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2008, 29 (08): : 1400 - 1402