Thermal control of a mechanically pumped two-phase loop

被引:11
|
作者
Li, Guanru [1 ]
Jiang, Haitao [2 ]
Zheng, Yi [1 ]
Zhang, Chengbin [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Key Lab Energy Thermal Convers & Control, Minist Educ, Nanjing 210096, Peoples R China
[2] 38th Res Inst China Elect Technol Corp, Hefei 230088, Peoples R China
基金
国家重点研发计划;
关键词
Minichannel evaporator; Two-phase loop; Temperature control; Feed-forward compensation; Model predictive control; CAPILLARY-DRIVEN; FLOW-CONTROL; HEAT-PIPE; PERFORMANCE; THERMOSIPHON;
D O I
10.1016/j.icheatmasstransfer.2022.106365
中图分类号
O414.1 [热力学];
学科分类号
摘要
With integration and miniaturization of electronic devices, the heat dissipation has grown exponentially, necessitating feasible thermal management systems and cooling alternatives. Among them, two-phase loop cooling is deemed to be highly effective, in which the minichannel evaporator is rendered as a mechanically pumped two-phase loop (MPTL), ensuring the precise thermal control. Herein, the temperature control accuracy of MPTL has been particularly emphasized by proposing the feed-forward offset-free model predictive controller (MPC), and compared with the PI controller that has also been structurally modified (namely, improved PI controller). MPC is designed, optimized and tuned based on the unsteady-state nonlinear analysis, addressing the challenges, such as frequent heat load fluctuations and various nonlinearities/uncertainties mainly encountered during the minichannel boiling. Results depict the superiority of MPC in terms of shorter transient time (measured by set-point tracking), higher temperature control accuracy and lower absolute error (IAE) index (both determined by disturbance rejection), mitigating the effect of flow-boiling uncertainties. Especially, the average transient time of MPC on MPTL has been found at least four times shorter than that of the improved PI controller. Also, IAE index of MPC on MPTL is better than that of the improved PI controller. Meanwhile, the temperature control accuracy of MPC on MPTL during disturbance suppression is as little as 0.2 degrees C, while that of the improved PI is higher (1.1 degrees C). The temperature control of the proposed controller (MPC) is therefore satisfactory based on which it can be engaged in MPTL technology for further development of electronic applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Numerical Simulation of the Mechanically Pumped Two-Phase cooling loop
    Liu Jie
    Zhou Enze
    Zhao Wenjun
    Cheng Cheng
    GREEN POWER, MATERIALS AND MANUFACTURING TECHNOLOGY AND APPLICATIONS, PTS 1 AND 2, 2011, 84-85 : 244 - 248
  • [2] Ground Test and on-Orbit Verification of a Mechanically Pumped Two-Phase Loop Using for Thermal Control of Spacecraft
    Meng, Qingliang
    Zhao, Zhenming
    Chen, Xianggui
    HEAT TRANSFER ENGINEERING, 2023, 44 (16-18) : 1624 - 1642
  • [3] INVESTIGATION OF CARBON DIOXIDE EXPLOSIVE BOILING IN SINGLE EVAPORATOR OF A TWO-PHASE MECHANICALLY PUMPED THERMAL CONTROL LOOP
    Sun Xi-Hui
    Huang Zhen-Cheng
    Xiao Wen-Jia
    Chen Yue
    He Zhen-Hui
    Pauw, A.
    van Es, J.
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 1: BIO HEAT TRANSFER, BOILING HEAT TRANSFER, COMPUTATIONAL HEAT TRANSFER, 2010, : 669 - 676
  • [4] Thermal vacuum test study of mechanically pumped two-phase loop for space remote sensor
    Meng Q.
    Zhao Z.
    Chen X.
    Zhu X.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2023, 49 (03): : 559 - 568
  • [5] Dynamic characteristics of a two-phase mechanically pumped cooling loop for avionics
    Qi, Shaohuan
    Xu, Zhaohao
    Wang, Jiale
    Xu, Yu
    CASE STUDIES IN THERMAL ENGINEERING, 2025, 67
  • [6] Simulation and experimental study of mechanically pumped two-phase loop for CCD
    Zhao Z.
    Meng Q.
    Zhang H.
    Zhao H.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2019, 45 (05): : 893 - 901
  • [7] Experimental study on active disturbance rejection temperature control of a mechanically pumped two-phase loop
    Zhang, Chengbin
    Li, Guanru
    Sun, Li
    Chen, Yongping
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 129 : 1 - 10
  • [8] Coupling Between an Accumulator and a Loop in a Mechanically Pumped Carbon Dioxide Two-Phase Loop
    Zhencheng Huang
    Zhenhui He
    Dongchuan Mo
    Xihui Sun
    Shushen Lu
    Wenjia Xiao
    Aswin Pauw
    Johannes van Es
    Elisa Laudi
    Microgravity Science and Technology, 2009, 21 : 23 - 29
  • [9] Coupling Between an Accumulator and a Loop in a Mechanically Pumped Carbon Dioxide Two-Phase Loop
    Huang, Zhencheng
    He, Zhenhui
    Mo, Dongchuan
    Sun, Xihui
    Lu, Shushen
    Xiao, Wenjia
    Pauw, Aswin
    van Es, Johannes
    Laudi, Elisa
    MICROGRAVITY SCIENCE AND TECHNOLOGY, 2009, 21 : 23 - 29
  • [10] Numerical Analysis of Wick-Type Two-Phase Mechanically Pumped Fluid Loop for Thermal Control of Electric Aircraft Motors
    Chang, Xinyu
    Fujita, Koji
    Nagai, Hiroki
    ENERGIES, 2022, 15 (05)