Selective Determination of Epinephrine in the Presence of Ascorbic Acid Using a Glassy Carbon Electrode Modified with Graphene

被引:31
|
作者
Li, Xia [1 ]
Chen, Meifeng [1 ]
Ma, Xinying [1 ]
机构
[1] Heze Univ, Dept Chem & Chem Engn, Heze 274015, Shandong, Peoples R China
关键词
ELECTROCHEMICAL PROPERTIES; NOREPINEPHRINE; DOPAMINE; BEHAVIOR;
D O I
10.2116/analsci.28.147
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A graphene-modified glassy carbon electrode was fabricated via a drop-casting method, and applied to the electrochemical detection of epinephrine. The capacity of the graphene-modified glassy carbon electrode for the selective detection of epinephrine was confirmed in a sufficient amount of ascorbic acid (2 mmol L-1) by cyclic voltammetry. The modified electrode showed an excellent electrocatalytical effect on the oxidation of epinephrine. A pair of well-defined redox waves were observed in voltammograms of epinephrine in a phosphate buffered solution (pH 4.0). The peak potentials of epinephrine remained unchanged, and the oxidation peak currents showed a linear relation versus the epinephrine concentration in the range of 3.85 x 10(-7) - 1.31 x 10(-5) mol L-1 and 1.31 x 10(-5) - 1.09 x 10(-4) mol L-1 with a correlation coefficient as follows: i(pa1) = 4.25 x 10(-6) - 1.99c (mol L-1), R-1 = 0.9953; i(pa2) = 4.31 x 10(-5) - 0.315c (mol L-1), R-2 = 0.9988. Detection limit is estimated to be 8.9 x 10(-8) mol L-1. Graphene-modified glassy carbon electrode was applied to epinephrine sample analysis, and the results were in good agreement with the standard values.
引用
收藏
页码:147 / 151
页数:5
相关论文
共 50 条
  • [21] Selective determination of dopamine in the presence of ascorbic acid using ferrocenyl-tethered PAMAM dendrimers modified glassy carbon electrode
    Quanpeng Chen
    Shiyun Ai
    Qiang Ma
    Huanshun Yin
    Journal of Applied Electrochemistry, 2010, 40 : 1379 - 1385
  • [22] Selective determination of epinephrine in the presence of ascorbic acid and uric acid by electrocatalytic oxidation at poly(eriochrome black T) film-modified glassy carbon electrode
    Yao, Hong
    Sun, Yuanyuan
    Lin, Xinhua
    Tang, Yuhai
    Liu, Ailin
    Guangwen, L.
    Wei, L.
    Zhang, Shaobo
    ANALYTICAL SCIENCES, 2007, 23 (06) : 677 - 682
  • [23] Determination of dopamine in the presence of ascorbic acid using poly (acridine red) modified glassy carbon electrode
    Zhang, YZ
    Jin, GY
    Wang, YL
    Yang, ZS
    SENSORS, 2003, 3 (10): : 443 - 450
  • [24] Selective Determination of Dopamine and Uric Acid at Poly(acid red 176) Modified Glassy Carbon Electrode in the Presence of Ascorbic Acid
    Li, Xiao-bo
    Xu, Guang-ri
    Hu, Rui-yuan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (02): : 1920 - 1927
  • [26] Cyclic voltammetry determination of epinephrine with a nano-gold modified glassy carbon electrode in the presence of high concentration ascorbic acid
    Zhang, H
    Gui, XQ
    Xu, Y
    Jin, BK
    CHINESE CHEMICAL LETTERS, 2002, 13 (02) : 153 - 156
  • [27] Selective Determination of Epinephrine in the Presence of Ascorbic Acid and Dopamine at Silver Doped Polyglycine Modified Electrode
    Li, Xia
    Chen, Meifeng
    Ma, Xinying
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (01): : 167 - 174
  • [28] Simultaneous determination of dopamine, uric acid and ascorbic acid using a glassy carbon electrode modified with reduced graphene oxide
    Wang, Huiwen
    Ren, Fangfang
    Wang, Caiqin
    Yang, Beibei
    Bin, Duan
    Zhang, Ke
    Du, Yukou
    RSC ADVANCES, 2014, 4 (51) : 26895 - 26901
  • [29] Selective determination of uric acid in the presence of ascorbic acid at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Tang, Hao
    Hu, Guang-zhi
    Jiang, Sheng-xiang
    Liu, Xia
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (12) : 2323 - 2328
  • [30] Poly(3-thiophenemalonic acid) Modified Glassy Carbon Electrode for Selective Determination of Dopamine and Urine Acid in the Presence of Ascorbic Acid
    Wan, Jia
    Xu, Guang-Ri
    Liu, Zhangsuo
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (12): : 12955 - 12962