Simultaneous Nitric Oxide/Atomic Oxygen Laser-Induced Fluorescence in an Arcjet Facility

被引:3
|
作者
Johansen, Craig T. [1 ]
Lincoln, Daniel A. [1 ]
Bathel, Brett F. [2 ]
Inman, Jennifer A. [2 ]
Danehy, Paul M. [2 ]
机构
[1] Univ Calgary, Mech & Mfg Engn, 2500 Univ Dr NW, Calgary, AB T2N 1N4, Canada
[2] NASA, Langley Res Ctr, Adv Measurements & Data Syst Branch, MS 493, Hampton, VA 23681 USA
基金
加拿大自然科学与工程研究理事会;
关键词
DENSITY-MEASUREMENTS; SPECTROSCOPY; EXCITATION; ATOMS;
D O I
10.2514/1.T4691
中图分类号
O414.1 [热力学];
学科分类号
摘要
Simultaneous nitric-oxide and atomic-oxygen laser-induced-fluorescence experiments were performed in the Hypersonic Materials Environmental Test System facility at the NASA Langley Research Center. The data serve as an experimental database for validation for chemical and thermal nonequilibrium models used in hypersonic flows. Measurements were taken over a wide range of stagnation enthalpies (6.7-18.5 MJ/kg) using an Earth atmosphere simulant with a composition of 75% nitrogen, 20% oxygen, and 5% argon (by volume). These are the first simultaneous measurements of nitric-oxide and atomic-oxygen laser-induced fluorescence to be reported in literature for the Hypersonic Materials Environmental Test System facility. The maximum atomic-oxygen laser-induced-fluorescence mean signal intensity was observed at a stagnation enthalpy of approximately 12 MJ/kg, whereas the maximum nitric-oxide laser-induced-fluorescence mean signal intensity was observed at a stagnation enthalpy of 6.7 MJ/kg. The experimental results were compared to a fluorescence model that assumes equilibrium conditions in the plenum and frozen chemistry in an isentropic nozzle expansion (Mach 5). The equilibrium calculations were performed using CANTERA v2.1.1 with 16 species. The fluorescence model captured the correlation in mean atomic-oxygen laser-induced-fluorescence and nitric-oxide laser-induced-fluorescence signal intensities over a large range of stagnation enthalpies tested. The agreement between equilibrium calculations and the experimental laser-induced fluorescence signals was better for nitric oxide than atomic oxygen. Very weak correlations between single-shot atomic-oxygen laser-induced-fluorescence and nitric-oxide laser-induced-fluorescence intensities were observed in the experiments at all of the stagnation enthalpy conditions. It was found that the overall magnitude of nitric-oxide laser-induced-fluorescence fluctuations was much larger than atomic-oxygen laser-induced-fluorescence fluctuations.
引用
收藏
页码:912 / 918
页数:7
相关论文
共 50 条
  • [21] Flow characterization of a diamond-depositing dc arcjet by laser-induced fluorescence
    Juchmann, W
    Luque, J
    Jeffries, JB
    APPLIED OPTICS, 2000, 39 (21) : 3704 - 3711
  • [22] LASER-INDUCED FLUORESCENCE DIAGNOSTIC FOR TEMPERATURE AND VELOCITY-MEASUREMENTS IN A HYDROGEN ARCJET PLUME
    LIEBESKIND, JG
    HANSON, RK
    CAPPELLI, MA
    APPLIED OPTICS, 1993, 32 (30): : 6117 - 6127
  • [23] Behaviour of atomic oxygen in a pulsed dielectric barrier discharge measured by laser-induced fluorescence
    Ono, R
    Yamashita, Y
    Takezawa, K
    Oda, T
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (16) : 2812 - 2816
  • [24] Evaluation of nitric oxide laser-induced fluorescence thermometry techniques in a hypersonic boundary layer
    Connor C. McDougall
    W. Schuyler Hinman
    Craig T. Johansen
    Brett F. Bathel
    Jennifer A. Inman
    Paul M. Danehy
    Experiments in Fluids, 2020, 61
  • [25] Ultrahigh-frame-rate nitric oxide planar laser-induced fluorescence imaging
    Jiang, Naibo
    Lempert, Walter R.
    OPTICS LETTERS, 2008, 33 (19) : 2236 - 2238
  • [26] Confocal, two-photon laser-induced fluorescence technique for the detection of nitric oxide
    Reeves, M
    Musculus, M
    Farrell, P
    APPLIED OPTICS, 1998, 37 (28): : 6627 - 6635
  • [27] Evaluation of nitric oxide laser-induced fluorescence thermometry techniques in a hypersonic boundary layer
    McDougall, Connor C.
    Hinman, W. Schuyler
    Johansen, Craig T.
    Bathel, Brett F.
    Inman, Jennifer A.
    Danehy, Paul M.
    EXPERIMENTS IN FLUIDS, 2020, 61 (04)
  • [28] Confocal, two-photon laser-induced fluorescence technique for the detection of nitric oxide
    Reeves, Mark
    Musculus, Mark
    Farrell, Patrick
    Applied Optics, 1998, 37 (28): : 6627 - 6635
  • [29] Two-photon nitric oxide laser-induced fluorescence measurements in a diesel engine
    Martin, GC
    Mueller, CJ
    Lee, CFF
    APPLIED OPTICS, 2006, 45 (09) : 2089 - 2100
  • [30] Laser-induced fluorescence measurements and modeling of nitric oxide in counterflow partially premixed flames
    Ravikrishna, RV
    Laurendeau, NM
    COMBUSTION AND FLAME, 2000, 122 (04) : 474 - 482