Comparison of Myocardial Scar Geometries from 2D and 3D LGE-MRI

被引:0
|
作者
Usta, Fatma [1 ,3 ]
Gueaieb, Wail [1 ]
White, James A. [2 ]
McKeen, Conor [3 ]
Ukwatta, Eranga [3 ]
机构
[1] Univ Ottawa, Elect & Comp Engn, Ottawa, ON, Canada
[2] Univ Calgary, Dept Cardiac Sci, Calgary, AB, Canada
[3] Carleton Univ, Syst & Comp Engn, Ottawa, ON, Canada
关键词
Shape Analysis; 3D LGE-MRI; Myocardial Scar; 2D vs 3D LGE-MRI; Scar Segmentation; INFARCT; SEGMENTATION; RESOLUTION;
D O I
10.1117/12.2293961
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Myocardial scar geometry may influence the sensitivity of predicting risk for ventricular tachycardia (VT) using computational models of the heart. This study aims to compare the differences in reconstructed geometry of scar generated using two-dimensional (2D) versus three-dimensional (3D) late gadolinium-enhanced magnetic resonance (LGE-MR) images. We used a retrospectively-acquired dataset of 17 patients with myocardial scar who underwent both 2D and 3D LGE-MR imaging. We segmented the scar manually in both 2D and 3D LGE-MRI using a multi-planar image processing software. We then reconstructed the 2D scar segmentation boundaries from 2D LGE-MRI to 3D surfaces using a LogOdds-based interpolation method. Finally, we assessed the 3D models of scar in both 3D and 2D-reconstructed techniques using several shape and volume metrics such as, fractal dimensions, number of connected components, mean scar volume, and normalized scar volume. The higher fractal dimension resulted for 3D may indicate that the 3D LGE-MRI produces a more complex surface geometry by better capturing the intact geometry of the scar. The 2D LGE-MRI produced a larger normalized scar volume (19.48 +/- 10 %) than the 3D LGE-MRI (10.92 +/- 7.12 %). We also provided a statistical analysis on the scar volume differences acquired from 2D and 3D LGE-MRI.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Automated subcortical volume estimation from 2D MRI in epilepsy, comparison with 3D MRI and implications for clinical trials
    Brownhilll, Daniel
    Chen, Ya-Chin
    Kreilkamp, Barbara
    Denby, Christine
    Bracewell, Martyn
    Biswas, Shubhabrata
    Das, Kumar
    Marson, Anthony
    Keller, Simon
    EPILEPSIA, 2021, 62 : 240 - 240
  • [22] Simulated radiographic bone and joint modeling from 3D ankle MRI: feasibility and comparison with radiographs and 2D MRI
    Nordeck, Shaun M.
    Koerper, Conrad E.
    Adler, Aaron
    Malhotra, Vidur
    Xi, Yin
    Liu, George T.
    Chhabra, Avneesh
    SKELETAL RADIOLOGY, 2017, 46 (05) : 651 - 664
  • [23] Simulated radiographic bone and joint modeling from 3D ankle MRI: feasibility and comparison with radiographs and 2D MRI
    Shaun M. Nordeck
    Conrad E. Koerper
    Aaron Adler
    Vidur Malhotra
    Yin Xi
    George T. Liu
    Avneesh Chhabra
    Skeletal Radiology, 2017, 46 : 651 - 664
  • [24] Hemimegalencephaly: 2D, 3D Ultrasound and MRI Correlation
    Romero, X. C.
    Molina, F. S.
    Pastor, E.
    Amaya, F.
    FETAL DIAGNOSIS AND THERAPY, 2011, 29 (03) : 257 - 260
  • [25] Comparison of 2D and 3D gamma analyses
    Pulliam, Kiley B.
    Huang, Jessie Y.
    Howell, Rebecca M.
    Followill, David
    Bosca, Ryan
    O'Daniel, Jennifer
    Kry, Stephen F.
    MEDICAL PHYSICS, 2014, 41 (02) : 021710
  • [26] Numerical simulation of cavitating flow in 2D and 3D inducer geometries
    Coutier-Delgosha, O
    Fortes-Patella, R
    Reboud, JL
    Hakimi, N
    Hirsch, C
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2005, 48 (02) : 135 - 167
  • [27] Myocardial blood flow quantification with PET comparison of 3D vs 2D aquisition
    Schepis, T.
    Gaemperli, O.
    Valenta, I.
    Treyer, V.
    Burger, C.
    Burger, C.
    Koepfli, P.
    Kaufmann, P. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S170 - S170
  • [28] Comparison of subclustering frequency determined from 2D and 3D data
    Flin, P
    Krywult, J
    TRACING COSMIC EVOLUTION WITH GALAXY CLUSTERS, PROCEEDINGS, 2002, 268 : 365 - 366
  • [29] Comparison for the results from 2D and 3D analysis for slope stability
    Peng, Wenxiang
    Mo, Jianjun
    Xie, Yujun
    ADVANCES IN CIVIL ENGINEERING, PTS 1-4, 2011, 90-93 : 255 - 259
  • [30] Design in 2D, model in 3D: Live 3D pose generation from 2D sketches
    Tosco, Paolo
    Mackey, Mark
    Cheeseright, Tim
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258