M2 quality factor measurement without power and wavelength limit based on infrared image technology

被引:0
|
作者
Wang, Zhao [1 ]
Liao, Lei [1 ]
Xing, Yingbin [1 ]
Luo, Xing [1 ]
Li, Haiqing [1 ]
Li, Jinyan [1 ]
Dai, Nengli [1 ]
机构
[1] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Wuhan, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
beam quality M-2; temperature field; infrared thermal imager; LASER-BEAM QUALITY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report on a method which can be used on more occasions for measuring the laser beam quality M-2 of light guided by optical fibers based on infrared thermometry. The infrared thermal imager has been used to detect the temperature field of the photothermal sensor which irradiated by fiber laser. Eliminating the error caused by the coefficient of thermal conductivity, by which the temperature field enable us to know the laser beam width in different positions along the direction of laser transmission. With these data, the optical field can be reconstructed. The beam quality M-2 can be received through curve fitting accurately, which agrees with IOS-standard measurements.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Measurement of Tomato Quality Attributes Based on Wavelength Ratio and Near-Infrared Spectroscopy
    Huang Yu-ping
    Lu, Renfu
    Qi Chao
    Chen Kun-jie
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (08) : 2362 - 2368
  • [22] Evaluation of the beam quality of supercontinuum source using supercontinunm M2 factor
    Jin, Aijun
    Hou, Jing
    Jiang, Zongfu
    Zhongguo Jiguang/Chinese Journal of Lasers, 2013, 40 (05):
  • [23] Image based machine learning for identification of M1 and M2 macrophages
    Rostam, Hassan Muhammad
    Reynolds, Paul M.
    Singh, Sonali
    Alexander, Morgan R.
    Gadegaard, Nikolaj
    Ghaemmaghami, Amir
    JOURNAL OF IMMUNOLOGY, 2016, 196
  • [24] Fast M2 measurement for fiber beams based on modal analysis
    Flamm, Daniel
    Schulze, Christian
    Bruening, Robert
    Schmidt, Oliver A.
    Kaiser, Thomas
    Schroeter, Siegmund
    Duparre, Michael
    APPLIED OPTICS, 2012, 51 (07) : 987 - 993
  • [25] Influences of CCD nonlinear response on measurement of propagation factor M2 of a laser beam
    Wang, You
    Kan, Hirofumi
    JOURNAL OF OPTICS, 2011, 13 (01)
  • [26] Complex amplitude reconstruction for dynamic beam quality M2 factor measurement with self-referencing interferometer wavefront sensor
    Du, Yongzhao
    Fu, Yuqing
    Zheng, Lixin
    APPLIED OPTICS, 2016, 55 (36) : 10180 - 10186
  • [27] Single shot M2 measurement for near infrared laser pulses in real-time
    Nagisetty, Siva Sankar
    Chyla, Michal
    Smrz, Martin
    Mocek, Tomas
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2019,
  • [28] Power-log Based Plateau Limit Histogram Equalization Algorithm for Infrared Image Enhancement
    Paul, Abhisek
    Biswas, Prantik
    Bhattacharya, Paritosh
    Maity, Santi Prasad
    2017 TENTH INTERNATIONAL CONFERENCE ON CONTEMPORARY COMPUTING (IC3), 2017, : 38 - 42
  • [29] Analysis of influence of thermally induced aberrations on laser beam quality factor (M2) in a high-power laser system
    Huang, Zheqiang
    Meng, Lingqiang
    Shen, Hua
    Han, Zhigang
    Zhu, Rihong
    OPTICAL ENGINEERING, 2018, 57 (02)
  • [30] Laser beam quality factor (M2) measured by distorted fresnel zone plates
    Cortes, R.
    Villagomez, R.
    Coello, V.
    Lopez, R.
    REVISTA MEXICANA DE FISICA, 2008, 54 (04) : 279 - 283