XAFS beam lines at Aichi Synchrotron Radiation Center dedicated to industrial use

被引:6
|
作者
Takeda, Yoshikazu [1 ]
机构
[1] Aichi Sci & Technol Fdn, Aichi Synchrotron Radiat Ctr, Seto, Aichi 4890985, Japan
关键词
D O I
10.1088/1742-6596/712/1/012146
中图分类号
O59 [应用物理学];
学科分类号
摘要
Aichi Synchrotron Radiation Center was designed for industrial use following five years of discussion among academia, industry and local government in the Aichi area. Among the six beam lines constructed, those that facilitated X-ray absorption fine structure (XAFS) analysis were given first priority. In addition to the hardware, attention was given to the development of operating procedures that were quick and user-friendly. The facility entered public service in March 2013. In the year 2013, 55% of the experiments involved XAFS analysis (hard X-ray, soft X-ray and vacuum ultraviolet regions) and in 2014 it was 57%. The range of research fields is very broad, emphasizing the importance of the XAFS beam lines.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] THE USE OF A SITEK POSITION-SENSITIVE DETECTOR FOR SYNCHROTRON RADIATION BEAM MONITORING AND ALIGNMENT
    HANSON, AL
    KWIATEK, W
    JONES, KW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 260 (2-3): : 529 - 533
  • [32] GAS BREMSSTRAHLUNG CONSIDERATIONS IN THE SHIELDING DESIGN OF THE ADVANCED PHOTON SOURCE SYNCHROTRON-RADIATION BEAM LINES
    IPE, NE
    FASSO, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 351 (2-3): : 534 - 544
  • [33] Radiation-hard beam position detector for use in the accelerator dump lines
    Degtiarenko, P
    Dotson, D
    Popov, V
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 1985 - 1987
  • [34] COMMON-AXIS ROTATIONALLY SYMMETRIC ANAMORPHIC MIRROR COMBINATIONS - APPLICATION TO SYNCHROTRON-RADIATION BEAM LINES
    ASPNES, DE
    KELSO, SM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1981, 71 (08) : 997 - 1001
  • [35] Use of XR-QA2 radiochromic films for quantitative imaging of a synchrotron radiation beam
    Di Lillo, F.
    Dreossi, D.
    Emiro, F.
    Fedon, C.
    Longo, R.
    Mettivier, G.
    Rigon, L.
    Russo, P.
    Tromba, G.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [36] In-situ precise angle monitoring on synchrotron radiation monochromator by use of pencil beam interferometer
    Qian, SN
    Takacs, P
    Dong, QL
    Hulbert, S
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 616 - 619
  • [37] THE USE OF AN OPTOELECTRONIC SEMICONDUCTOR FOR MONITORING ELECTRON-BEAM POSITION AT THE DARESBURY SYNCHROTRON RADIATION SOURCE
    CLARKE, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 418 - 421
  • [38] Use of high power electron beam radiation for treatment of municipal and industrial wastes
    Auslender, VL
    MODERN PROBLEMS OF ELECTROSTATICS WITH APPLICATIONS IN ENVIRONMENT PROTECTION, 1999, 63 : 199 - 217
  • [39] Institut d'Astrophysique Spatiale (IAS) 0.1-15KeV synchrotron radiation facility beam lines.
    Dhez, P
    Jourdain, E
    Hainaut, O
    Hochedez, JF
    Labeque, A
    Salvetat, P
    Song, XY
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 134 - 142
  • [40] MIRROR AND GRATING SURFACE FIGURE REQUIREMENTS FOR GRAZING-INCIDENCE SYNCHROTRON RADIATION BEAM LINES - POWER LOADING EFFECTS
    HULBERT, SL
    SHARMA, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3): : 491 - 497