Velocity Measurement at Carotid Siphon: Quantitative Comparison of Phase Contrast MRI and Computational Fluid Dynamics

被引:0
|
作者
Zhang, Chi [1 ]
Yang, Jinfeng [1 ]
Ding, Ning [1 ]
Chang, Feiyan [2 ]
Xie, Sheng [2 ]
Li, Deyu [3 ]
Hou, Xiaoxu [4 ]
机构
[1] Beihang Univ, Beijing 100083, Peoples R China
[2] China Japan Friendship Hosp, Beijing 100029, Peoples R China
[3] Beihang Univ, State Key Lab Virtual Real Technol & Syst, Beijing 100083, Peoples R China
[4] Natl Inst Food & Drug Control, Beijing 102629, Peoples R China
关键词
Carotid siphon; Phase contrast magnetic resonance imaging; Computational fluid dynamics; Blood flow; Velocity field; BLOOD-FLOW; MAGNETIC-RESONANCE; VALIDATION; ARTERIES;
D O I
10.1007/978-981-10-9035-6_92
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Phase contrast magnetic resonance imaging (PC MRI) and the computational fluid dynamics (CFD) are two of the most important technologies in the investigation on the velocity field in blood vessels in vivo. In order to quantitatively compare the differences between the two methods, the blood flow velocity measurements based on PC MRI and patient-specific CFD were conducted at internal carotid artery from 9 healthy volunteers. The 3D velocity field calculated from PC MRI data were compared with CFD simulation in 5 planes covering the carotid siphon. Then the resistance index (RI), and errors in the magnitude and direction of velocity were calculated between the two methods. The results showed that the flow patterns of PC MRI and CFD were similar, and the velocity distribution and RI was in good agreement. But there were significant differences in the velocity magnitude near the posterior knee and vessel wall, while the directional error was larger at the center of the artery. These comparison between PC MRI and CFD may guide the development of CFD technology and improve its accuracy.
引用
收藏
页码:499 / 504
页数:6
相关论文
共 50 条
  • [41] Phase contrast MRI segmentation using velocity and intensity
    Persson, M
    Solem, JE
    Markenroth, K
    Svensson, J
    Heyden, A
    SCALE SPACE AND PDE METHODS IN COMPUTER VISION, PROCEEDINGS, 2005, 3459 : 119 - 130
  • [42] Noise estimation for the velocity in MRI phase-contrast
    Irarrazaval, Pablo
    Dehghan Firoozabadi, Ali
    Uribe, Sergio
    Tejos, Cristian
    Sing-Long, Carlos
    MAGNETIC RESONANCE IMAGING, 2019, 63 : 250 - 257
  • [43] Venc Design and Velocity Estimation for Phase Contrast MRI
    Zhao, Shen
    Ahmad, Rizwan
    Potter, Lee C.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (12) : 3712 - 3724
  • [44] A perspective review: Technical study of combining phase contrast magnetic Resonance imaging and computational fluid dynamics for blood flow on carotid bifurcation artery
    Adib, Mohd Azrul Hisham Mohd
    Hong, Lim Sheh
    Abdullah, Mohd Shafie
    Hassan, Radhiana
    Abd Aziz, Azian
    Wada, Shigeo
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2020, 14 (04) : 7609 - 7621
  • [45] Minimizing the blood velocity differences between phase-contrast magnetic resonance imaging and computational fluid dynamics simulation in cerebral arteries and aneurysms
    Adib, Mohd Azrul Hisham Mohd
    Ii, Satoshi
    Watanabe, Yoshiyuki
    Wada, Shigeo
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (09) : 1605 - 1619
  • [46] Minimizing the blood velocity differences between phase-contrast magnetic resonance imaging and computational fluid dynamics simulation in cerebral arteries and aneurysms
    Mohd Azrul Hisham Mohd Adib
    Satoshi Ii
    Yoshiyuki Watanabe
    Shigeo Wada
    Medical & Biological Engineering & Computing, 2017, 55 : 1605 - 1619
  • [47] In Vitro Validation of Flow Measurement With Phase Contrast MRI at 3 Tesla Using Stereoscopic Particle Image Velocimetry and Stereoscopic Particle Image Velocimetry-Based Computational Fluid Dynamics
    Khodarahmi, Iman
    Shakeri, Mostafa
    Kotys-Traughber, Melanie
    Fischer, Stefan
    Sharp, M. Keith
    Amini, Amir A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (06) : 1477 - 1485
  • [48] Simulation of brisk and fast phase-contrast magnetic resonance imaging by computational fluid dynamics
    Hershey, BL
    Doyle, M
    Kortright, E
    Anayiotos, A
    2003 ADVANCES IN BIOENGINEERING, 2003, : 141 - 142
  • [49] Allometric scaling of wall shear stress from mice to humans: quantification using cine phase-contrast MRI and computational fluid dynamics
    Greve, Joan M.
    Les, Andrea S.
    Tang, Beverly T.
    Blomme, Mary T. Draney
    Wilson, Nathan M.
    Dalman, Ronald L.
    Pelc, Norbert J.
    Taylor, Charles A.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2006, 291 (04): : H1700 - H1708
  • [50] Fluid Mechanics Approach to Perfusion Quantification: Vasculature Computational Fluid Dynamics Simulation, Quantitative Transport Mapping (QTM) Analysis of Dynamics Contrast Enhanced MRI, and Application in Nonalcoholic Fatty Liver Disease Classification
    Zhang, Qihao
    Luo, Xianfu
    Zhou, Liangdong
    Nguyen, Thanh D.
    Prince, Martin R.
    Spincemaille, Pascal
    Wang, Yi
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (03) : 980 - 990