A comparison between ammonia-water and water-lithium bromide solutions in absorption heat transformers

被引:55
|
作者
Kurem, E [1 ]
Horuz, I
机构
[1] Univ Uludag, Bursa Vocat Sch Tech Sci, TR-10659 Gorukle, Bursa, Turkey
[2] Univ Uludag, Fac Engn & Architecture, Dept Mech Engn, TR-10659 Gorukle, Bursa, Turkey
关键词
D O I
10.1016/S0735-1933(01)00247-0
中图分类号
O414.1 [热力学];
学科分类号
摘要
The study included an investigation to analyze the Absorption Heat Pump (AHP) and Absorption Heat Transformers (AHT) using ammonia-water and water-lithium bromide solutions. A fundamental AHP and AHT systems are described and the operating sequence is explained. Since the AHT systems widely use ammonia-water solution with ammonia as the refrigerant and water-lithium bromide solution with water as the refrigerant, the comparison of the two is presented in respect of the coefficient of performance (COP), the flow ratio (FR) and the maximum system pressure. It is concluded that the AHT system using water-lithium bromide solution provided better performance than the system using ammonia-water solution. (C) 2001 Elsevier Science Ltd.
引用
收藏
页码:427 / 438
页数:12
相关论文
共 50 条
  • [31] THERMODYNAMIC ANALYSIS AND COMPARISON OF SINGLE EFFECT WATER-LITHIUM BROMIDE ABSORPTION HEAT TRANSFORMER UNDER THE HIGH- AND LOW-TEMPERATURE CONDITIONS
    Hao, Zhaolong
    Ma, Xuehu
    Lan, Zhong
    [J]. HEAT TRANSFER RESEARCH, 2015, 46 (04) : 399 - 415
  • [32] Comparison and analysis of lithium bromide-water absorption chillers using plastic heat transfer tubes and traditional lithium bromide-water absorption chillers
    Zhang, Xue-dong
    [J]. World Academy of Science, Engineering and Technology, 2010, 41 : 573 - 576
  • [33] Performance comparison of double-effect parallel-flow and series flow water-lithium bromide absorption systems
    Arun, MB
    Maiya, MP
    Murthy, SS
    [J]. APPLIED THERMAL ENGINEERING, 2001, 21 (12) : 1273 - 1279
  • [34] Exergy analysis of an ammonia-water absorption system
    Barhoumi, M.
    Ben Ezzine, N.
    Bellagi, A.
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2009, 6 (05) : 698 - 714
  • [35] Investigation of a ammonia-water absorption chiller performance
    Kong, Dingfeng
    Liu, Jianhua
    Zhang, Liang
    Fang, Zhiyun
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [36] Study on the characteristics of ammonia-water absorption refrigerator
    Saito, K
    Kimijima, S
    Takei, T
    Kawai, S
    [J]. NATURAL WORKING FLUIDS'98: IIR - GUSTAV LORENTZEN CONFERENCE, 1998, 1998 (04): : 550 - 560
  • [37] Second law-based thermodynamic analysis of water-lithium bromide absorption refrigeration system
    Kilic, Muhsin
    Kaynakli, Omer
    [J]. ENERGY, 2007, 32 (08) : 1505 - 1512
  • [38] Ammonia-water absorption in vertical tubular absorbers
    Fernández-Seara, J
    Sieres, J
    Rodríguez, C
    Vázquez, M
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2005, 44 (03) : 277 - 288
  • [39] Experimental study of an ammonia-water absorption chiller
    Le Lostec, Brice
    Galanis, Nicolas
    Millette, Jocelyn
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (08): : 2275 - 2286
  • [40] Theoretical comparison between lithium bromide water vapour resorption and absorption cycles
    Sabir, HM
    Eames, IW
    [J]. APPLIED THERMAL ENGINEERING, 1998, 18 (08) : 683 - 692