Monte Carlo calculation of organ dose coefficients for internal dosimetry: Results of an international intercomparison exercise

被引:5
|
作者
Zankl, Maria [1 ]
Gomez-Roy, Jose-Maria [2 ]
Moraleda, Montserrat [2 ]
Reichelt, Uwe [3 ]
Akar, Deepak K. [4 ,5 ]
Borbinha, Jorge [6 ]
Desorgher, Laurent [7 ]
Di Maria, Salvatore [6 ]
EL Bakkali, Jaafar [8 ]
Fantinova, Karin [9 ]
Ferrari, Paolo [10 ]
Gossio, Sebastian [11 ]
Hunt, John [12 ]
Jovanovic, Zoran [13 ]
Kim, Han Sung [14 ]
Krstic, Dragana [13 ]
Lee, Yi-Kang [15 ]
Nadar, Minal Y. [4 ]
Nikezic, Dragoslav [13 ]
Patni, Hemant K. [4 ]
Murugan, Manohari [15 ]
Trivin, Sebastian [16 ]
机构
[1] Helmholtz Zentrum Munchen GmbH, German Res Ctr Environm Hlth, Inst Radiat Med, Ingolstadter Landstr 1, D-85764 Neuherberg, Germany
[2] CIEMAT Ctr Invest Energet Medioambientales & Tecn, Madrid, Spain
[3] Tech Univ Dresden, Dresden, Germany
[4] Bhabha Atom Res Ctr, Mumbai, Maharashtra, India
[5] Homi Bhabha Natl Inst, Mumbai, Maharashtra, India
[6] Univ Lisbon, Inst Super Tecn, Ctr Ciencias & Tecnol Nucl, Lisbon, Portugal
[7] Mil Hosp Mohammed V, Nucl Med Dept, Rabat, Morocco
[8] SURO Natl Radiat Protect Inst, Prague, Czech Republic
[9] ENEA Radiat Protect Inst, Bologna, Italy
[10] Autoridad Regulatoria Nucl, Buenos Aires, DF, Argentina
[11] CNEN, Inst Radioprotecao & Dosimetria, Rio De Janeiro, Brazil
[12] Univ Kragujevac, Fac Sci, Kragujevac, Serbia
[13] Korea Inst Radiol & Med Sci KIRAMS, Seoul, South Korea
[14] Univ Paris Saclay, CEA, Serv Etud Reacteurs & Math Appl, F-91191 Gif Sur Yvette, France
[15] Indira Gandhi Ctr Atom Res, Kalpakkam, Tamil Nadu, India
[16] CNEA, Comis Nacl Energia Atom, Buenos Aires, DF, Argentina
关键词
Intercomparison exercise; Monte Carlo; Reference phantoms; Internal dosimetry; SIMULATION; SPECTRA; NUCLEI;
D O I
10.1016/j.radmeas.2021.106661
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
EURADOS Working Group 6 has organized an intercomparison exercise on the use of the ICRP Reference Computational Phantoms with radiation transport codes. This paper summarizes the results of a specific task from the intercomparison exercise modelling internal radiation sources. The quantities to be calculated were absorbed fractions and specific absorbed fractions for monoenergetic photon and electron sources as well as Svalues for two radionuclides in four source organs. Twelve participants from eleven countries participated in this specific task using the Monte Carlo radiation transport codes FLUKA, Geant4, the MCNP code family, PenEasy, TRIPOLI-4 and VMC. Although some participants provided initial solutions in good agreement with the master solution evaluated by the organizers, differences of factors or even orders of magnitude were also found. Following feedback from the organizer, most participants submitted revised solutions that were mostly in better agreement with the master solution, although this was not always the case. Some initial and revised results are discussed in detail in this paper, and the reasons of mistakes are described as far as they were revealed by the participants. A full account of all results is presented in specific annexes as supplemental material.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] EURADOS intercomparison exercise on Monte Carlo modelling of a medical linear accelerator
    Caccia, Barbara
    Le Roy, Maiwenn
    Blideanu, Valentin
    Andenna, Claudio
    Arun, Chairmadurai
    Czarnecki, Damian
    El Bardouni, Tarek
    Gschwind, Regine
    Huot, Nicolas
    Martin, Eric
    Zink, Klemens
    Zoubair, Mariam
    Price, Robert
    de Carlan, Loic
    [J]. ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2017, 53 (04): : 314 - 321
  • [32] Visual Monte Carlo and its application to internal and external dosimetry
    Hunt, JG
    da Silva, FC
    de Souza-Santos, D
    Malatova, I
    Foltanova, S
    Dantas, BM
    Azeredo, A
    Isakson, M
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 345 - 350
  • [33] Monte Carlo based voxel phantoms for in vivo internal dosimetry
    Gomez Ros, J. M.
    Moraleda, M.
    Lopez, M. A.
    Navarro, T.
    Navarro, J. F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 161 - 165
  • [34] Monte Carlo studies in the field of internal dosimetry of incorporated radionuclides
    Gualdrini, G
    [J]. COMPUTING RADIATION DOSIMETRY - CRD 2002, WORKSHOP PROCEEDINGS, 2004, : 125 - 146
  • [35] A Monte Carlo method for calculating Bayesian uncertainties in internal dosimetry
    Puncher, M.
    Birchall, A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 132 (01) : 1 - 12
  • [36] Radiotherapy dosimetry parameters intercomparison among eight gel dosimeters by Monte Carlo simulation
    Mariotti, V
    Gayol, A.
    Pianoschi, T.
    Mattea, F.
    Vedelago, J.
    Perez, P.
    Valente, M.
    Alva-Sanchez, M.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 190
  • [37] International intercomparison on internal dose assessment (ICIDOSE 2017)
    Roberts, Gareth
    Castellani, Carlo-Maria
    Andrasi, Andor
    Giussani, Augusto
    Pazmandi, Tamas
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (02) : 444 - 464
  • [38] CT scanner-specific organ dose coefficients generated by Monte Carlo calculation for the ICRP adult male and female reference computational phantoms
    Jansen, Jan T. M.
    Shrimpton, Paul C.
    Edyvean, Sue
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (22):
  • [39] DosiTest: a virtual intercomparison of clinical dosimetry trials based on Monte-Carlo modelling
    Villoing, D.
    Garcia, M.
    Ferrer, L.
    Caselles, O.
    Cassol, E.
    Botta, F.
    Cremonesi, M.
    Kouame, D.
    Tourneret, J.
    Batatia, H.
    Bardies, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S200 - S200
  • [40] A Monte Carlo approach to estimate organ dose uncertainty
    Taulbee, TD
    Neton, JW
    [J]. HEALTH PHYSICS, 2003, 84 (06): : S212 - S213