Monte Carlo calculation of organ dose coefficients for internal dosimetry: Results of an international intercomparison exercise

被引:5
|
作者
Zankl, Maria [1 ]
Gomez-Roy, Jose-Maria [2 ]
Moraleda, Montserrat [2 ]
Reichelt, Uwe [3 ]
Akar, Deepak K. [4 ,5 ]
Borbinha, Jorge [6 ]
Desorgher, Laurent [7 ]
Di Maria, Salvatore [6 ]
EL Bakkali, Jaafar [8 ]
Fantinova, Karin [9 ]
Ferrari, Paolo [10 ]
Gossio, Sebastian [11 ]
Hunt, John [12 ]
Jovanovic, Zoran [13 ]
Kim, Han Sung [14 ]
Krstic, Dragana [13 ]
Lee, Yi-Kang [15 ]
Nadar, Minal Y. [4 ]
Nikezic, Dragoslav [13 ]
Patni, Hemant K. [4 ]
Murugan, Manohari [15 ]
Trivin, Sebastian [16 ]
机构
[1] Helmholtz Zentrum Munchen GmbH, German Res Ctr Environm Hlth, Inst Radiat Med, Ingolstadter Landstr 1, D-85764 Neuherberg, Germany
[2] CIEMAT Ctr Invest Energet Medioambientales & Tecn, Madrid, Spain
[3] Tech Univ Dresden, Dresden, Germany
[4] Bhabha Atom Res Ctr, Mumbai, Maharashtra, India
[5] Homi Bhabha Natl Inst, Mumbai, Maharashtra, India
[6] Univ Lisbon, Inst Super Tecn, Ctr Ciencias & Tecnol Nucl, Lisbon, Portugal
[7] Mil Hosp Mohammed V, Nucl Med Dept, Rabat, Morocco
[8] SURO Natl Radiat Protect Inst, Prague, Czech Republic
[9] ENEA Radiat Protect Inst, Bologna, Italy
[10] Autoridad Regulatoria Nucl, Buenos Aires, DF, Argentina
[11] CNEN, Inst Radioprotecao & Dosimetria, Rio De Janeiro, Brazil
[12] Univ Kragujevac, Fac Sci, Kragujevac, Serbia
[13] Korea Inst Radiol & Med Sci KIRAMS, Seoul, South Korea
[14] Univ Paris Saclay, CEA, Serv Etud Reacteurs & Math Appl, F-91191 Gif Sur Yvette, France
[15] Indira Gandhi Ctr Atom Res, Kalpakkam, Tamil Nadu, India
[16] CNEA, Comis Nacl Energia Atom, Buenos Aires, DF, Argentina
关键词
Intercomparison exercise; Monte Carlo; Reference phantoms; Internal dosimetry; SIMULATION; SPECTRA; NUCLEI;
D O I
10.1016/j.radmeas.2021.106661
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
EURADOS Working Group 6 has organized an intercomparison exercise on the use of the ICRP Reference Computational Phantoms with radiation transport codes. This paper summarizes the results of a specific task from the intercomparison exercise modelling internal radiation sources. The quantities to be calculated were absorbed fractions and specific absorbed fractions for monoenergetic photon and electron sources as well as Svalues for two radionuclides in four source organs. Twelve participants from eleven countries participated in this specific task using the Monte Carlo radiation transport codes FLUKA, Geant4, the MCNP code family, PenEasy, TRIPOLI-4 and VMC. Although some participants provided initial solutions in good agreement with the master solution evaluated by the organizers, differences of factors or even orders of magnitude were also found. Following feedback from the organizer, most participants submitted revised solutions that were mostly in better agreement with the master solution, although this was not always the case. Some initial and revised results are discussed in detail in this paper, and the reasons of mistakes are described as far as they were revealed by the participants. A full account of all results is presented in specific annexes as supplemental material.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Monte Carlo calculation of organ and effective dose rates from ground contaminated by Am-241: Results of an international intercomparison exercise
    Eakins, J.
    Huet, C.
    Brkic, H.
    Capello, K.
    Desorgher, L.
    Epstein, L.
    Hunt, J. G.
    Kim, H. S.
    Krstic, D.
    Lee, Y-K
    Manohari, M.
    Nikezic, D.
    Shukrun, R. H.
    Souza-Santos, D.
    Tyminska, K.
    [J]. RADIATION MEASUREMENTS, 2021, 148
  • [2] Monte Carlo calculation of organ and effective doses due to photon and neutron point sources and typical X-ray examinations: Results of an international intercomparison exercise
    Huet, Christelle
    Eakins, Jonathan
    Zankl, Maria
    Maria Gomez-Ros, Jose
    Jansen, Jan
    Moraleda, Montserrat
    Struelens, Lara
    Akar, Deepak K.
    Borbinha, Jorge
    Brkic, Hrvoje
    Duc Ky Bui
    Capello, Kevin
    Thi My Linh Dang
    Desorgher, Laurent
    Di Maria, Salvatore
    Epstein, Lior
    Faj, Dario
    Fantinova, Karin
    Ferrari, Paolo
    Gossio, Sebastian
    Hunt, John
    Jovanovic, Zoran
    Kim, Han Sung
    Krstic, Dragana
    Ngoc Thiem Le
    Lee, Yi-Kang
    Murugan, Manohari
    Nadar, Minal Y.
    Ngoc-Quynh Nguyen
    Nikezic, Dragoslav
    Patni, Hemant K.
    Santos, Denison Souza
    Tremblay, Marilyn
    Trivino, Sebastian
    Tyminska, Katarzyna
    [J]. RADIATION MEASUREMENTS, 2022, 150
  • [3] Comparison of dose calculation algorithms with Monte Carlo simulation for surface dosimetry
    Chow, J.
    Jiang, R.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4308 - 4308
  • [4] Monte carlo calculation of internal dose based on SPECT/CT
    Ahunbay, E.
    Steinfelds, E.
    Hellman, R.
    Peng, C.
    Li, X.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2568 - 2568
  • [5] Monte Carlo computed dose kernels and convolution dose calculations for rapid internal dosimetry
    Steinfelds, E.
    Ahunbay, E.
    Li, X.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2471 - 2471
  • [6] Comparison of IMRT verification by means of film dosimetry and Monte Carlo dose calculation
    Gotzfried, T.
    Rickhey, M.
    Treutwein, W.
    Bogner, L.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 28 - 28
  • [7] A Methodology for Monte Carlo Simulation Time Reduction in Dose Calculation for Reference Dosimetry
    Reis, C.
    Nicolucci, P.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3714 - 3714
  • [8] Selection of bone dosimetry models for application in Monte Carlo simulations to provide CT scanner-specific organ dose coefficients
    Jansen, Jan T. M.
    Shrimpton, Paul C.
    Holroyd, John
    Edyvean, Sue
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (12):
  • [9] Validation of DPM Monte Carlo code for internal beta dose calculation
    Owczarczyk, J.
    Owczarczyk, K.
    Recko, W.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S322 - S322
  • [10] Monte Carlo modelling of Germanium detectors for the measurement of low energy photons in internal dosimetry: Results of an international comparison
    Gomez-Ros, J. M.
    de Carlan, L.
    Franck, D.
    Gualdrini, G.
    Lis, M.
    Lopez, M. A.
    Moraleda, M.
    Zankl, M.
    Badal, A.
    Capello, K.
    Cowan, P.
    Ferrari, P.
    Heide, B.
    Henniger, J.
    Hooley, V.
    Hunt, J.
    Kinase, S.
    Kramer, G. H.
    Loehnert, D.
    Lucas, S.
    Nuttens, V.
    Packer, L. W.
    Reichelt, U.
    Vrba, T.
    Sempau, J.
    Zhang, B.
    [J]. RADIATION MEASUREMENTS, 2008, 43 (2-6) : 510 - 515