Results of ascending aortic and arch replacement for type A aortic dissection

被引:26
|
作者
Uchida, Keiji [1 ]
Minami, Tomoyuki [1 ]
Cho, Tomoki [1 ]
Yasuda, Shota [1 ]
Kasama, Keiichiro [1 ]
Suzuki, Shinichi [1 ]
Masuda, Munetaka [1 ]
机构
[1] Yokohama City Univ, Med Ctr, Cardiovasc Ctr, Yokohama, Kanagawa, Japan
来源
关键词
type A acute aortic dissection; distal aortic event; total arch replacement; ascending aortic replacement; MIDTERM OUTCOMES; ELEPHANT TRUNK;
D O I
10.1016/j.jtcvs.2020.02.087
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The outcomes of emergency surgery for type A acute aortic dissection have improved. However, ascending aortic replacement sometimes leads to dilatation of the distal aorta. The present study reviewed our outcomes of ascending aortic replacement and total arch replacement in patients with type A acute aortic dissection. Methods: A total of 253 patients with type A acute aortic dissection underwent a central repair operation. Our standard technique was ascending aortic replacement. Total arch replacement was performed only when entry existed in the major curvature of the aortic arch and the proximal descending aorta. A total of 169 patients (67%) underwent ascending aortic replacement, and 84 patients (33%) underwent total arch replacement. Hospital death due to initial surgery, dilatation of the distal aorta greater than 5 cm, new occurrence of aortic dissection, any distal aortic surgery, and aortic-related deaths were defined as distal aortic events. Results: The mortality was 7.1% in the ascending aortic replacement group and 6.0% in the total arch replacement group. Postoperative computed tomography was performed in 162 patients in the ascending aortic replacement group. The false lumen of the residual aortic arch had thrombosed and healed in 94 patients (58%) and remained present in 68 patients (42%). The distal aortic event-free rate in the ascending aortic replacement group decreased from 74% at 5 years to 51% at 9 years, and the rate in the total arch replacement group was 83% at 5 to 9 years (P <.01). For the ascending aortic replacement group, more patients with a dissected arch had a distal aortic event compared with patients with a healed arch (P<.01). Conclusions: Total arch replacement was associated with fewer distal aortic events. We may expand the indications for total arch replacement in stable patients.
引用
收藏
页码:1025 / 1031
页数:7
相关论文
共 50 条
  • [31] EMERGENCY GRAFT REPLACEMENT OF THE AORTIC-ARCH FOR ACUTE TYPE-A AORTIC DISSECTION
    KAZUI, T
    YAMADA, O
    KOMATSU, S
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 1992, 33 (02): : 211 - 215
  • [32] Total aortic arch replacement in acute type A aortic dissection - a single institutional experience
    Shetty, Varun
    Rajan, Venkatesa Kumar Anakaputhur
    Makwana, Rohan Kiritkumar
    Shetty, Devi Prasad
    Narayan, Pradeep
    [J]. INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 39 (05) : 489 - 496
  • [33] Proximal and extended aortic arch replacement in acute DeBakey type I aortic dissection
    Narita, Masahiko
    Tsutsui, Masahiro
    Ushioda, Ryouhei
    Kikuchi, Yuta
    Shirasaka, Tomonori
    Ishikawa, Natsuya
    Kamiya, Hiroyuki
    [J]. FRONTIERS IN SURGERY, 2023, 10
  • [34] Theoretical Feasibility of Using Arch Branched Endograft Devices for Repair of Post Type A Aortic Dissection in Patients With Prior Ascending Aortic Replacement
    Ni, Leng
    Wong, Alfred C. C.
    Hui, Victor
    Chan, Yiu Che
    Cheng, Stephen W. K.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2023, 30 (04) : 561 - 570
  • [35] Ascending Aortic Cannulation for Acute Type A Aortic Dissection
    Iwakura, Atsushi
    Kusuhara, Yoshitaka
    Ann, Kenta
    Nakatsuka, Daisuke
    Hirise, Keiichi
    Yamanaka, Kazuo
    [J]. CIRCULATION, 2010, 122 (21)
  • [36] Type A aortic dissection after 'zone 0' thoracic endovascular aortic repair for type 1 hybrid aortic arch replacement of arch aneurysm
    Han, Sung Joon
    Shim, Man-Shik
    Han, Woo Sik
    Cho, Hyun Jin
    Kang, Min-Woong
    Kang, Shin Kwang
    Yu, Jae Hyeon
    Na, Myung Hoon
    [J]. JOURNAL OF SURGICAL CASE REPORTS, 2020, (12):
  • [37] Combined Ascending Aortic Stent-Graft and Inner Branched Arch Device for Type A Aortic Dissection
    Law, Yuk
    Tsilimparis, Nikolaos
    Rohlffs, Fiona
    Makaloski, Vladimir
    Debus, E. Sebastian
    Koelbel, Tilo
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2018, 25 (05) : 561 - 565
  • [38] Periprosthetic pseudoaneurysm and right atrial fistula in type A aortic dissection treated with ascending aortic replacement
    D'Ascoli, Riccardo
    Paredes Vignoli, Federico
    Gil Albarova, Oscar
    Hornero Sos, Fernando
    [J]. CIRUGIA CARDIOVASCULAR, 2014, 21 (03): : 219 - 220
  • [39] Validity of a limited ascending and hemiarch replacement for acute type a aortic dissection
    Shiono, Motomi
    Hata, Mitsumasa
    Sezai, Akira
    Niino, Tetsuya
    Yagi, Shinya
    Negishi, Nanao
    [J]. ANNALS OF THORACIC SURGERY, 2006, 82 (05): : 1665 - 1669
  • [40] Outcomes of ascending aorta and partial arch replacement with entry resection for DeBakey type I acute aortic dissection
    Fukunaga, Naoto
    Wakami, Tatsuto
    Shimoji, Akio
    Maeda, Toshi
    Mori, Otohime
    Yoshizawa, Kosuke
    Tamura, Nobushige
    [J]. GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2024, 72 (04) : 216 - 224