Design of a video capsule endoscopy system with low-power ASIC for monitoring gastrointestinal tract

被引:21
|
作者
Liu, Gang [1 ]
Yan, Guozheng [1 ]
Zhu, Bingquan [1 ]
Lu, Li [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Precise Engn & Intelligent Microsyst, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Wireless capsule endoscopy (WCE); Application-specific integrated circuit (ASIC); Image compression; Improved JPEG-LS encoder; RF transmitter; In vivo trials; WIRELESS; COMPRESSION;
D O I
10.1007/s11517-016-1472-2
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In recent years, wireless capsule endoscopy (WCE) has been a state-of-the-art tool to examine disorders of the human gastrointestinal tract painlessly. However, system miniaturization, enhancement of the image-data transfer rate and power consumption reduction for the capsule are still key challenges. In this paper, a video capsule endoscopy system with a low-power controlling and processing application-specific integrated circuit (ASIC) is designed and fabricated. In the design, these challenges are resolved by employing a microimage sensor, a novel radio frequency transmitter with an on-off keying modulation rate of 20 Mbps, and an ASIC structure that includes a clock management module, a power-efficient image compression module and a power management unit. An ASIC-based prototype capsule, which measures I broken vertical bar 11 mm x 25 mm, has been developed here. Test results show that the designed ASIC consumes much less power than most of the other WCE systems and that its total power consumption per frame is the least. The image compression module can realize high near-lossless compression rate (3.69) and high image quality (46.2 dB). The proposed system supports multi-spectral imaging, including white light imaging and autofluorescence imaging, at a maximum frame rate of 24 fps and with a resolution of 400 x 400. Tests and in vivo trials in pigs have proved the feasibility of the entire system, but further improvements in capsule control and compression performance inside the ASIC are needed in the future.
引用
收藏
页码:1779 / 1791
页数:13
相关论文
共 50 条
  • [21] Establishment of an interpretation system for video capsule endoscopy for obscure gastrointestinal bleeding
    Goto, Hidemi
    Nakamura, Masanao
    Ohmiya, Naoki
    Hirooka, Yoshiki
    Itoh, Akihiro
    [J]. JOURNAL OF GASTROENTEROLOGY, 2010, 45 (04) : 468 - 469
  • [22] Capsule endoscopy of the upper gastrointestinal tract - The need for a second endoscopy
    Peter, S
    Heuss, LT
    Beglinger, C
    Degen, L
    [J]. DIGESTION, 2005, 72 (04) : 242 - 247
  • [23] European Society of Gastrointestinal Endoscopy guideline for video capsule endoscopy
    Rey, JF
    Gay, G
    Kruse, A
    Lambert, R
    [J]. ENDOSCOPY, 2004, 36 (07) : 656 - 658
  • [24] Low-power DCT-based compressor for wireless capsule endoscopy
    Shabani, Ahmad
    Timarchi, Somayeh
    [J]. SIGNAL PROCESSING-IMAGE COMMUNICATION, 2017, 59 : 83 - 95
  • [25] Design of Video Display Driving System for Low-power Electrowetting Display
    Chen Zhe-liang
    Lin Shan-ling
    Lin Zhi-xian
    Liao Qin-kai
    Li Tian-tian
    Tang Biao
    [J]. ACTA PHOTONICA SINICA, 2020, 49 (02)
  • [26] Gastrointestinal bleeding diagnosed using video capsule endoscopy
    Sokol, H.
    Seksik, P.
    Wendum, D.
    Bellanger, J.
    Parc, Y.
    Cosnes, J.
    Beaugerie, L.
    [J]. GUT, 2009, 58 (09) : 1206 - +
  • [27] Video capsule endoscopy in the evaluation of obscure gastrointestinal bleeding
    Chutkan, RK
    Balba, NH
    Adams, TL
    Johnson, M
    [J]. GASTROINTESTINAL ENDOSCOPY, 2002, 55 (05) : AB133 - AB133
  • [28] Video capsule endoscopy in the evaluation of obscure gastrointestinal bleeding
    Chutkan, RK
    Nader, BH
    Tonya, AL
    Marsha, J
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2002, 97 (09): : S82 - S82
  • [29] Upper gastrointestinal video capsule endoscopy: The state of the art
    Papaefthymiou, Apostolis
    Koffas, Apostolos
    Laskaratos, Faidon-Marios
    Epstein, Owen
    [J]. CLINICS AND RESEARCH IN HEPATOLOGY AND GASTROENTEROLOGY, 2022, 46 (03)
  • [30] A Low-Power Subsample-based Image Compression Algorithm for Capsule Endoscopy
    Mostafa, Atahar
    Wahid, Khan
    Ko, Seok-Bum
    [J]. 2012 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 2012), 2012, : 109 - 112