Multi-institution Assessment of the Accuracy of Cardiac Computed Tomography in Preparation for Superior Cavopulmonary Connection

被引:0
|
作者
Nunes, Mariana De Oliveira [1 ]
Overman, David M. [2 ]
Casey, Susan A. [1 ]
Witt, Dawn R. [1 ]
Schmidt, Christian W. [1 ]
Griffin, Lindsay [3 ]
Rigsby, Cynthia K. [3 ]
Han, B. Kelly [1 ,2 ]
机构
[1] Minneapolis Heart Inst & Fdn, Minneapolis, MN USA
[2] Mayo Clin Childrens Minnesota Cardiovasc Collabor, Minneapolis, MN USA
[3] Ann & Robert H Lurie Childrens Hosp Chicago, Chicago, IL 60611 USA
关键词
pediatric; congenital heart disease; congenital heart surgery; CHD; univentricular heart; BIDIRECTIONAL GLENN ANASTOMOSIS; FUNCTIONAL SINGLE-VENTRICLE; HEART-DISEASE; MAGNETIC-RESONANCE; RISK-FACTORS; NORWOOD PROCEDURE; INTERSTAGE DEATH; CATHETERIZATION; RECONSTRUCTION; ANGIOGRAPHY;
D O I
10.1177/21501351211035685
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Patients with single ventricle (SV) congenital heart disease (CHD) undergo several interventions in the first years of life. Advanced diagnostics are required for interstage assessment of anatomy, but are associated with significant diagnostic risk. We sought to evaluate image quality, risk, and accuracy of cardiac computed tomography (CCT) for evaluation of anatomy prior to superior cavopulmonary connection (SCPC) compared to surgical findings across 2 institutions. Methods: A retrospective evaluation of image quality, risk, and accuracy of pre-SCPC CCT was performed at 2 institutions between January 1, 2010 and September 30, 2016. Results: CCT was performed in 90 SV CHD patients with a median age of 4.03 months (interquartile range [IQR] 3.36, 5.33) prior to SCPC. Image quality was optimal (84%) or good (16%) in all patients, without significant discrepancy compared to surgical findings. 7 patients (8%) required interventional cardiac catheterization subsequent to CCT and before surgical intervention. 49% of scans were performed without sedation, 43% of scans were performed with mild to moderate sedation, and 8% of scans were performed with general anesthesia. The median total procedural dose-length product (DLP) was 18 (IQR 14, 26) mGy*cm, estimating an age adjusted radiation dose of 1.4 millisievert (mSv). One minor (1%) adverse event was reported within 24 h of the CCT. Surgical complications were unrelated to the presurgical findings. Conclusions: CCT for pre-SCPC evaluation is safe, with excellent accuracy for anatomy at the time of surgical intervention across 2 institutions. In select patients, noninvasive evaluation with CCT may be indicated.
引用
收藏
页码:700 / 705
页数:6
相关论文
共 50 条
  • [31] Assessment of cavopulmonary connections by advanced imaging: value of flat-detector computed tomography
    Gloeckler, Martin
    Koch, Andreas
    Halbfass, Julia
    Greim, Verena
    Rueffer, Andre
    Cesnjevar, Robert
    Achenbach, Stephan
    Dittrich, Sven
    CARDIOLOGY IN THE YOUNG, 2013, 23 (01) : 18 - 26
  • [32] Intraluminal tumor cells and prognostic accuracy of endometrial cancer stage criteria: A multi-institution study
    Felix, Ashley S.
    Sinnott, Jennifer A.
    Cohn, David E.
    Havrilesky, Laura J.
    Olawaiye, Alexander B.
    Mariani, Andrea
    Rodriquez, Monica
    Brett, Mary Anne
    Dinoi, Giorgia
    Meade, Caitlin E.
    Hall, Bobbie
    Goldfeld, Ester
    Elishaev, Esther
    Sherman, Mark E.
    Suarez, Adrian A.
    GYNECOLOGIC ONCOLOGY, 2023, 178 : 130 - 137
  • [33] Safety, reliability and accuracy of small renal tumour biopsies: results from a multi-institution registry
    Richard, Patrick O.
    Jewett, Michael A. S.
    Tanguay, Simon
    Saarela, Olli
    Liu, Zhihui Amy
    Pouliot, Frederic
    Kapoor, Anil
    Rendon, Ricardo
    Finelli, Antonio
    BJU INTERNATIONAL, 2017, 119 (04) : 543 - 549
  • [34] VOLUME ASSESSMENT ACCURACY IN COMPUTED TOMOGRAPHY: A PHANTOM STUDY
    Prionas, N. D.
    Ray, S.
    Boone, J. M.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2009, 57 (01) : 120 - 120
  • [35] Volume assessment accuracy in computed tomography: a phantom study
    Prionas, Nicolas D.
    Ray, Shonket
    Boone, John M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 168 - 180
  • [36] Early superior cavopulmonary connection with preoperative computer tomography shows comparable outcomes for infants following Norwood palliation
    Bellsham-Revell, Hannah R.
    Tarmahomed, Abdulla
    Chou, Catie
    Wong, James
    Mathur, Sujeev
    Vigneswaran, Trisha
    Salih, Caner
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 62 (02)
  • [37] Computerized Decision Support for Bladder Cancer Treatment Response Assessment in CT Urography: Effect on Diagnostic Accuracy in Multi-Institution Multi-Specialty Study
    Sun, Di
    Hadjiiski, Lubomir
    Alva, Ajjai
    Zakharia, Yousef
    Joshi, Monika
    Chan, Heang-Ping
    Garje, Rohan
    Pomerantz, Lauren
    Elhag, Dean
    Cohan, Richard H.
    Caoili, Elaine M.
    Kerr, Wesley T.
    Cha, Kenny H.
    Kirova-Nedyalkova, Galina
    Davenport, Matthew S.
    Shankar, Prasad R.
    Francis, Isaac R.
    Shampain, Kimberly
    Meyer, Nathaniel
    Barkmeier, Daniel
    Woolen, Sean
    Palmbos, Phillip L.
    Weizer, Alon Z.
    Samala, Ravi K.
    Zhou, Chuan
    Matuszak, Martha
    TOMOGRAPHY, 2022, 8 (02) : 644 - 656
  • [38] Assessment of superior cavo-pulmonary anastomoses (Glenn shunt) by cardiac magnetic resonance imaging in comparison with multi-slice computed tomography
    Gamal El-Deen, Marwa Ali
    Ibrahim, Ahmed Samir
    Abdeldayem, Emad H.
    Elia, Remon Zaher
    Romeih, Soha
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [39] Assessment of superior cavo-pulmonary anastomoses (Glenn shunt) by cardiac magnetic resonance imaging in comparison with multi-slice computed tomography
    Marwa Ali Gamal El-Deen
    Ahmed Samir Ibrahim
    Emad H. Abdeldayem
    Remon Zaher Elia
    Soha Romeih
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [40] Quantitative assessment of the superior sagittal sinus on unenhanced computed tomography
    Fanous, Randy
    Leung, Andrew
    Karlik, Stephen
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (03) : 336 - 342