Evaluation of Model-Based Biomimetic Control of Prosthetic Finger Force for Grasp

被引:0
|
作者
Luo, Qi [1 ]
Niu, Chuanxin M. [1 ,2 ]
Liu, Jiayue [1 ]
Chou, Chih-Hong [1 ]
Hao, Manzhao [1 ]
Lan, Ning [1 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Lab Neurorehabil Engn, Sch Biomed Engn, Shanghai 200030, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Dept Rehabil Med, Shanghai 200025, Peoples R China
[3] Shanghai Jiao Tong Univ, Inst Med Robot, Shanghai 200240, Peoples R China
关键词
Force; Prosthetic hand; Biological system modeling; Task analysis; Transducers; Force control; Torque; Biomimetic control; neuromuscular reflex; neuromorphic computing; prosthetic hand; electromyography (EMG); INFORMATION CAPACITY; STRETCH REFLEX; HAND; MUSCLE; TENDON; MOVEMENTS; STIFFNESS; LENGTH;
D O I
10.1109/TNSRE.2021.3106304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Restoring neuromuscular reflex properties in the control of a prosthetic hand may potentially approach human-level grasp functions in the prosthetic hand. Previous studies have confirmed the feasibility of real-time emulation of a monosynaptic spinal reflex loop for prosthetic control. This study continues to explore how well the biomimetic controller could enable the amputee to perform force-control tasks that required both strength and error-tolerance. The biomimetic controller was programmed on a neuromorphic chip for real-time emulation of reflex. The model-calculated force of finger flexor was used to drive a torque motor, which pulled a tendon that flexed prosthetic fingers. Force control ability was evaluated in a "press-without-break" task, which required participants to press a force transducer toward a target level, but never exceeding a breakage threshold. The same task was tested either with the index finger or the full hand; the performance of the biomimetic controller was compared to a proportional linear feedback (PLF) controller, and the contralateral normal hand. Data from finger pressing task in 5 amputees showed that the biomimetic controller and the PLF controller achieved 95.8% and 66.9% the performance of contralateral finger in success rate; 50.0% and 25.1% in stability of force control; 59.9% and 42.8% in information throughput; and 51.5% and 38.4% in completion time. The biomimetic controller outperformed the PLF controller in all performance indices. Similar trends were observed with full-hand grasp task. The biomimetic controller exhibited capacity and behavior closer to contralateral normal hand. Results suggest that incorporating neuromuscular reflex properties in the biomimetic controller may provide human-like capacity of force regulation, which may enhance motor performance of amputees operating a tendon-driven prosthetic hand.
引用
收藏
页码:1723 / 1733
页数:11
相关论文
共 50 条
  • [31] Model-based predictive force control in milling: determination of reference trajectory
    Schwenzer M.
    Adams O.
    Klocke F.
    Stemmler S.
    Abel D.
    [J]. Production Engineering, 2017, 11 (2) : 107 - 115
  • [32] Hybrid model-based force/position control: theory and experimental verification
    Osypiuk, Rafael
    Finkerneyer, Bernd
    [J]. ROBOTICA, 2006, 24 : 775 - 783
  • [33] Model-Based Force Control of Pneumatic Actuators With Long Transmission Lines
    Turkseven, Melih
    Ueda, Jun
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2018, 23 (03) : 1292 - 1302
  • [34] Multi-DOF Model-Based Force Control for Telerobotic Applications
    Hart, J. Scot
    Niemeyer, Guenter
    [J]. IEEE/RSJ 2010 INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2010), 2010, : 5282 - 5287
  • [35] Model-Based Signal Processing for the Force Control of Biaxial Gantry Robots
    Flixeder, Stefan
    Glueck, Tobias
    Boeck, Martin
    Kugi, Andreas
    [J]. IFAC PAPERSONLINE, 2017, 50 (01): : 3208 - 3214
  • [36] Artificial finger skin having ridges and distributed tactile sensors used for grasp force control
    Yamada, D
    Maeno, T
    Yamada, Y
    [J]. IROS 2001: PROCEEDINGS OF THE 2001 IEEE/RJS INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-4: EXPANDING THE SOCIETAL ROLE OF ROBOTICS IN THE NEXT MILLENNIUM, 2001, : 686 - 691
  • [37] Evaluation of Finger Force Control Ability in Terms of Multi-Finger Synergy
    Lee, Minhyuk
    Lee, Jeongsoo
    Shin, Joonho
    Bae, Joonbum
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2019, 27 (06) : 1253 - 1262
  • [38] Model-based predictive force control in milling increasing productivity by safe process control
    Adams O.
    Schwenzer M.
    Stemmler S.
    Klocke F.
    Abel D.
    [J]. 1600, Carl Hanser Verlag (112): : 133 - 136
  • [39] Comparison between model-based and measured force polytopes: towards isometric force capacity evaluation
    Rezzoug, N.
    Hernandez, V.
    Jacquier-Bret, J.
    Gorce, P.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 : 172 - 174
  • [40] Model-Based Feedforward Derivative Compensation For Prosthetic Hands
    Engeberg, Erik D.
    Meek, Sanford G.
    [J]. 2008 2ND IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB 2008), VOLS 1 AND 2, 2008, : 61 - +