Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification

被引:37
|
作者
Heussel, C. P. [1 ]
Kappes, J. [2 ]
Hantusch, R. [1 ]
Hartlieb, S. [1 ]
Weinheimer, O. [3 ]
Kauczor, H. -U. [4 ]
Eberhardt, R. [2 ]
机构
[1] Univ Heidelberg Hosp, Dept Intervent & Diagnost Radiol, Thoraxklin Heidelberg, D-69126 Heidelberg, Germany
[2] Univ Heidelberg Hosp, Dept Pneumol & Crit Care Med, Thoraxklin Heidelberg, D-69126 Heidelberg, Germany
[3] Johannes Gutenberg Univ Mainz, Dept Intervent & Diagnost Radiol, D-55131 Mainz, Germany
[4] Univ Heidelberg Hosp, Dept Diagnost Radiol, D-69120 Heidelberg, Germany
关键词
COPD; Diagnostic imaging; MDCT imaging techniques in COPD; Lung attenuation; Contrast enhancement; LUNG-VOLUME REDUCTION; PULMONARY-EMPHYSEMA; COMPUTED DENSITY; QUANTITATIVE CT; SURFACE-AREA; MORPHOMETRY; PROTOCOL; INDEX; MASK;
D O I
10.1016/j.ejrad.2009.03.023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Systemic, interventional and surgical treatments have gone new ways in treatment of emphysema. For longitudinal therapy monitoring and as end-points for clinical trials, quantification of the disease is necessary. Sensitive, easy to measure, as well as stable and reproducible parameters have to be characterized. One parameter that might affect emphysema quantification is IV contrast enhancement, which might also be indicated. Whether or not the contrast enhanced scan is also suited for emphysema quantification or an additional scan is necessary, a retrospective analysis of 12 adult patients undergoing clinically indicated both, a non-enhanced and enhanced thin section MSCT within a week (median 0 days, range 0-4 days) was done. The in-house YACTA software was used for automatic quantification of lung and emphysema volume, emphysema index, mean lung density, and 5th, 10th, 15th percentile. After IV contrast administration, the median CT derived lung volume decreased mild by 1.1%, while median emphysema volume decreased by relevant 11%. This results in a decrease of median emphysema index by 9%. The median lung density (15th percentile) increased after contrast application by 18 HU( 9 HU). CT quantification delivers emphysema values that are clearly affected by IV contrast application. The detected changes after contrast applications how the results of higher density in the lung parenchyma. Therefore the amount of quantified emphysema is reduced and the lung density increased after contrast enhancement. In longitudinal analyses, non-enhanced scans should be the reference, while enhanced scans cannot be used. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:473 / 478
页数:6
相关论文
共 50 条
  • [41] A Comparison of Cranial Cavity Extraction Tools for Non-contrast Enhanced CT Scans in Acute Stroke Patients
    Vass, L.
    Moore, M. J.
    Hanayik, T.
    Mair, G.
    Pendlebury, S. T.
    Demeyere, N.
    Jenkinson, M.
    [J]. NEUROINFORMATICS, 2022, 20 (03) : 587 - 598
  • [42] Prevalence and characteristics of intravertebral enhancement on contrast-enhanced CT scans in cancer patients
    Rasselet, Benjamin
    Larbi, Ahmed
    Viala, Pierre
    Molinari, Nicolas
    Tetreau, Raphael
    Faruch-Bilfeld, Marie
    Taourel, Patrice
    Cyteval, Catherine
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2017, 86 : 1 - 5
  • [43] Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer
    Ukihide Tateishi
    Tetsuo Maeda
    Tsuyoshi Morimoto
    Mototaka Miyake
    Yasuaki Arai
    E. Edmund Kim
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 1627 - 1634
  • [44] Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer
    Tateishi, Ukihide
    Maeda, Tetsuo
    Morimoto, Tsuyoshi
    Miyake, Mototaka
    Arai, Yasuaki
    Kim, E. Edmund
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (10) : 1627 - 1634
  • [45] An HPC Pipeline for Calcium Quantification of Aortic Root From Contrast-Enhanced CCT Scans
    Minghini, Giada
    Cavallo, Armando Ugo
    Miola, Andrea
    Sisini, Valentina
    Calore, Enrico
    Fortini, Francesca
    Micheloni, Rino
    Rizzo, Paola
    Schifano, Sebastiano Fabio
    Sega, Francesco Vieceli Dalla
    Zambelli, Cristian
    [J]. IEEE ACCESS, 2023, 11 : 101309 - 101319
  • [46] Alternative solution of virtual biomodeling based on CT-scans
    Groesel, Martin
    Gfoehler, Margit
    Peham, Christian
    [J]. JOURNAL OF BIOMECHANICS, 2009, 42 (12) : 2006 - 2009
  • [47] Reconstructing mammalian turbinates from noisy CT-scans
    Fulkerson, Brian
    Van Valkenbargh, Blaire
    [J]. JOURNAL OF MORPHOLOGY, 2007, 268 (12) : 1075 - 1075
  • [48] Automatic Quantification of Atherosclerosis in Contrast-Enhanced MicroCT Scans of Mouse Aortas Ex Vivo
    Stadelmann, Vincent A.
    Boyd, Gabrielle
    Guillot, Martin
    Bienvenu, Jean-Guy
    Glaus, Charles
    Varela, Aurore
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2021, 2021
  • [50] Virtual non-enhanced dual-energy computed tomography reconstruction: a candidate to replace true non-enhanced computed tomography scans in the setting of suspected liver alveolar echinococcosis
    Kantarci, Mecit
    Aydin, Sonay
    Kahraman, Aysegul
    Ogul, Hayri
    Irgul, Baris
    Levent, Akin
    [J]. DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2023, 29 (06): : 736 - 740