Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification

被引:37
|
作者
Heussel, C. P. [1 ]
Kappes, J. [2 ]
Hantusch, R. [1 ]
Hartlieb, S. [1 ]
Weinheimer, O. [3 ]
Kauczor, H. -U. [4 ]
Eberhardt, R. [2 ]
机构
[1] Univ Heidelberg Hosp, Dept Intervent & Diagnost Radiol, Thoraxklin Heidelberg, D-69126 Heidelberg, Germany
[2] Univ Heidelberg Hosp, Dept Pneumol & Crit Care Med, Thoraxklin Heidelberg, D-69126 Heidelberg, Germany
[3] Johannes Gutenberg Univ Mainz, Dept Intervent & Diagnost Radiol, D-55131 Mainz, Germany
[4] Univ Heidelberg Hosp, Dept Diagnost Radiol, D-69120 Heidelberg, Germany
关键词
COPD; Diagnostic imaging; MDCT imaging techniques in COPD; Lung attenuation; Contrast enhancement; LUNG-VOLUME REDUCTION; PULMONARY-EMPHYSEMA; COMPUTED DENSITY; QUANTITATIVE CT; SURFACE-AREA; MORPHOMETRY; PROTOCOL; INDEX; MASK;
D O I
10.1016/j.ejrad.2009.03.023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Systemic, interventional and surgical treatments have gone new ways in treatment of emphysema. For longitudinal therapy monitoring and as end-points for clinical trials, quantification of the disease is necessary. Sensitive, easy to measure, as well as stable and reproducible parameters have to be characterized. One parameter that might affect emphysema quantification is IV contrast enhancement, which might also be indicated. Whether or not the contrast enhanced scan is also suited for emphysema quantification or an additional scan is necessary, a retrospective analysis of 12 adult patients undergoing clinically indicated both, a non-enhanced and enhanced thin section MSCT within a week (median 0 days, range 0-4 days) was done. The in-house YACTA software was used for automatic quantification of lung and emphysema volume, emphysema index, mean lung density, and 5th, 10th, 15th percentile. After IV contrast administration, the median CT derived lung volume decreased mild by 1.1%, while median emphysema volume decreased by relevant 11%. This results in a decrease of median emphysema index by 9%. The median lung density (15th percentile) increased after contrast application by 18 HU( 9 HU). CT quantification delivers emphysema values that are clearly affected by IV contrast application. The detected changes after contrast applications how the results of higher density in the lung parenchyma. Therefore the amount of quantified emphysema is reduced and the lung density increased after contrast enhancement. In longitudinal analyses, non-enhanced scans should be the reference, while enhanced scans cannot be used. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:473 / 478
页数:6
相关论文
共 50 条
  • [1] Can BMD of the lumbar spine be reliably determined in non-enhanced and enhanced spiral CT scans?
    Link, TM
    Koppers, BB
    Bauer, J
    Eckstein, F
    Lu, Y
    Rummeny, EJ
    [J]. RADIOLOGY, 2002, 225 : 419 - 420
  • [2] MEASUREMENT OF RADIATION DOSE TO THE EYE LENS IN NON-ENHANCED CT SCANS OF THE BRAIN
    Alwasiah, Reem
    Jawhari, Abdulkarim
    Al Orri, Rafal
    Khafaji, Mawya
    Al Bahiti, Sarah
    [J]. RADIATION PROTECTION DOSIMETRY, 2021, 195 (01) : 56 - 60
  • [3] CONTRAST-ENHANCED CT SCANS IN PEDIATRICS
    NAIDICH, TP
    ZIMMERMAN, RA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1986, 256 (23): : 3284 - 3284
  • [4] PERIPORTAL CONTRAST ENHANCEMENT ON CT-SCANS OF THE LIVER
    HAMMERMAN, AM
    KOTNER, LM
    DOYLE, TB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (02) : 313 - 315
  • [5] Virtual non-enhanced dual-energy CT reconstruction may replace true non-enhanced CT scans in the setting of suspected active hemorrhage
    Walter, Sven S.
    Schneeweiss, Sven
    Maurer, Michael
    Kraus, Mareen S.
    Wichmann, Julian L.
    Bongers, Malte N.
    Lescan, Mario
    Bamberg, Fabian
    Othman, Ahmed E.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 109 : 218 - 222
  • [6] AI-BASED AUTOMATED DETECTION OF INTRACRANIAL HEMORRHAGE ON NON-ENHANCED CT SCANS
    Herweh, C.
    Mokli, Y.
    Bellot, P.
    Schmitt, N.
    Joly, O.
    Weyland, C.
    Ringleb, P.
    Nagel, S.
    [J]. INTERNATIONAL JOURNAL OF STROKE, 2020, 15 (1_SUPPL) : 295 - 295
  • [7] Automatic segmentation and quantification of the cardiac structures from non-contrast-enhanced cardiac CT scans
    Shahzad, Rahil
    Bos, Daniel
    Budde, Ricardo P. J.
    Pellikaan, Karlijn
    Niessen, Wiro J.
    van der Lugt, Aad
    van Walsum, Theo
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (09): : 3798 - 3813
  • [8] Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT scans for diagnosing ovarian cancer recurrence
    Kitajima, Kazuhiro
    Ueno, Yoshiko
    Suzuki, Kayo
    Kita, Masato
    Ebina, Yasuhiko
    Yamada, Hideto
    Senda, Michio
    Maeda, Tetsuo
    Sugimura, Kazuro
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3557 - 3562
  • [9] Automatic quantification of epicardial fat volume on non-enhanced cardiac CT scans using a multi-atlas segmentation approach
    Shahzad, Rahil
    Bos, Daniel
    Metz, Coert
    Rossi, Alexia
    Kirisli, Hortense
    van der Lugt, Aad
    Klein, Stefan
    Witteman, Jacqueline
    de Feyter, Pim
    Niessen, Wiro
    van Vliet, Lucas
    van Walsum, Theo
    [J]. MEDICAL PHYSICS, 2013, 40 (09)
  • [10] Strengths and Weaknesses of Non-enhanced and Contrast-enhanced Cadaver Computed Tomography Scans in the Teaching of Gross Anatomy in an Integrated Curriculum
    Paech, Daniel
    Klopries, Kerstin
    Nawrotzki, Ralph
    Schlemmer, Heinz-Peter
    Giesel, Frederik L.
    Kirsch, Joachim
    Schultz, Jobst-Hendrik
    Kuner, Thomas
    Doll, Sara
    [J]. ANATOMICAL SCIENCES EDUCATION, 2022, 15 (01) : 143 - 154