Investigation of Sun Protection Issues via the Active and Passive Building Integration of Active Solar Energy Systems: A Case Study of the Renovation of an Existing Building in Cyprus

被引:4
|
作者
Efthymiou, M. [1 ]
Kontonis, P. R. [1 ]
Leonidou, A. [2 ]
Kazanakis, G. [1 ]
Vassiliades, C. [1 ]
机构
[1] Univ Cyprus, Sch Engn, Dept Architecture, POB 20537, CY-1678 Nicosia, Cyprus
[2] Univ Cyprus, Sch Engn, Dept Mech & Mfg Engn, POB 20537, CY-1678 Nicosia, Cyprus
关键词
ARCHITECTURAL DESIGN; OPTIMIZATION; ZERO;
D O I
10.1088/1755-1315/410/1/012063
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The demand for a continuous and extensive use of buildings in contemporary central business districts without proper maintenance has led to an aging building stock. The need for refurbishment and use of these buildings, based on the Energy Performance of Buildings Directive (EPBD) in Cyprus, is a challenge that all real estate asset managers need to face. This paper aims to examine whether specific building integrated active solar systems (BIPV), along with their basic operation can be used as passive shading devices as part of a double shell, as indicated in the case study for the renovation of an existing mixed-use building in Nicosia, Cyprus. The proposed research starts with an analysis of building and site geometry and an investigation into a philosophy of operation through a literature review, along with the presentation of case studies where these active solar systems are integrated on double building shells. Digital energy simulations are performed where the technologies are examined as a passive shading device, as part of the double shell of the renovated building. These simulations aim to analyse whether the system can cover the energy needs of the aforementioned building, whilst providing adequate sun protection. Consequent to the results of the digital simulation, the heating and cooling energy loads - in order to keep the interior of the simulated building within thermal comfort levels - are examined, thus affording the opportunity to compare and contrast the before and after situation. Moreover, the annual primary energy production of the integrated systems is calculated and compared with the building 's annual energy needs. The ultimate aim of this work is to determine the environmental sustainability of these building integration solutions for the refurbishment of existing buildings.
引用
收藏
页数:11
相关论文
共 48 条
  • [31] Fire risk assessment and efficiency study of active and passive protection methods in reducing the risk of fire in a control room of at an industrial building
    Askaripoor, Taleb
    Shirali, Gholam Abbas
    Yarahmadi, Rasool
    Kazemi, Elahe
    JOURNAL OF HEALTH AND SAFETY AT WORK, 2018, 8 (01) : 93 - +
  • [32] A fundamental study of intelligent building envelope systems capable of passive dehumidification and solar heat collection utilizing renewable energy
    Lee, Haksung
    Ozaki, Akihito
    Lee, Myonghyang
    Cho, Wanghee
    ENERGY AND BUILDINGS, 2019, 195 : 139 - 148
  • [33] Energy and economic analysis of geothermal-solar trigeneration systems: A case study for a hotel building in Ischia
    Buonomano, Annamaria
    Calise, Francesco
    Palombo, Adolfo
    Vicidomini, Maria
    APPLIED ENERGY, 2015, 138 : 224 - 241
  • [34] Integrating active and passive solar strategies in modular residential positive energy building in semi-arid climates: Insights from the TDART project
    Chorak, Aicha
    Mahdaoui, Mustapha
    Ben Taher, Mohamed Amine
    Kaitouni, Samir Idrissi
    Afass, Ayoub
    Ouardouz, Mustapha
    Ahachad, Mohammed
    ENERGY REPORTS, 2025, 13 : 1239 - 1265
  • [35] Investigation of a building-integrated solar photovoltaic-wind-battery hybrid energy system: A case study
    Sinha, Sunanda
    Chandel, Shyam Singh
    Malik, Prashant
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (15) : 21534 - 21539
  • [36] Savings through the use of adaptive predictive control of thermo-active building systems (TABS): A case study
    Schmelas, Martin
    Feldmann, Thomas
    Bollin, Elmar
    APPLIED ENERGY, 2017, 199 : 294 - 309
  • [37] USING UPPER STOREYS AS SEMI-ACTIVE TUNED MASS DAMPER BUILDING SYSTEMS - A CASE STUDY ANALYSIS
    Chey, M. H.
    Rodgers, Geoffrey W.
    Chase, J. Geoffrey
    Mander, John B.
    BULLETIN OF THE NEW ZEALAND SOCIETY FOR EARTHQUAKE ENGINEERING, 2010, 43 (02): : 126 - 133
  • [38] Practical Cost effectiveness Analysis for Solar Energy Systems: Case study of stand-alone retail building
    Legrene, Inoussa
    Wong, Tony
    Dessaint, Louis-A.
    18TH INTERNATIONAL CONFERENCE ON COMPATIBILITY, POWER ELECTRONICS AND POWER ENGINEERING, CPE-POWERENG 2024, 2024,
  • [39] Comprehensive economic evaluations of a residential building with solar photovoltaic and battery energy storage systems: An Australian case study
    Akter, M. N.
    Mahmud, M. A.
    Oo, Amanullah M. T.
    ENERGY AND BUILDINGS, 2017, 138 : 332 - 346
  • [40] Investigating the link between well-being and energy use; an explorative case study between passive and active domestic energy management systems
    Pelenur, Marcos J.
    Cruickshank, Heather J.
    BUILDING AND ENVIRONMENT, 2013, 65 : 26 - 34