A Reconfigurable Multiplanar In Vitro Simulator for Real-Time Absolute Motion With External and Musculotendon Forces

被引:3
|
作者
Green, Joshua T. [1 ]
Hale, Rena F. [2 ]
Hausselle, Jerome [3 ]
Gonzalez, Roger V. [4 ]
机构
[1] Univ Texas El Paso, Coll Engn, Dept Met Mat & Biomed Engn, 500 West Univ Ave, El Paso, TX 79968 USA
[2] Mayo Clin, Orthopaed Biomech Lab, 200 1st St Southwest, Rochester, MN 55905 USA
[3] Oklahoma State Univ, Coll Engn Architecture & Technol, Mech & Aerosp Engn, 218 Engn North, Stillwater, OK 74078 USA
[4] Univ Texas El Paso, Coll Engn, Dept Engn Educ & Leadership, 500 West Univ Ave, El Paso, TX 79968 USA
基金
美国国家科学基金会;
关键词
ROBOTIC SYSTEM; KNEE OSTEOARTHRITIS; JOINT; MODEL; BIOMECHANICS; LIMB; JUMP;
D O I
10.1115/1.4037853
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Advancements in computational musculoskeletal biomechanics are constrained by a lack of experimental measurement under real-time physiological loading conditions. This paper presents the design, configuration, capabilities, accuracy, and repeatability of The University of Texas at El Paso Joint Load Simulator (UTJLS) by testing four cadaver knee specimens with 47 real-time tests including heel and toe squat maneuvers with and without musculotendon forces. The UTJLS is a musculoskeletal simulator consisting of two robotic manipulators and eight musculotendon actuators. Sensors include eight tension load cells, two force/torque systems, nine absolute encoders, and eight incremental encoders. A custom control system determines command output for position, force, and hybrid control and collects data at 2000 Hz. Controller configuration performed forward-dynamic control for all knee degrees-of-freedom (DOFs) except knee flexion. Actuator placement and specimen potting techniques uniquely replicate muscle paths. Accuracy and repeatability standard deviations across specimen during squat simulations were equal or less than 8 N and 5N for musculotendon actuators, 30N and 13N for ground reaction forces (GRFs), and 4.4 N.m and 1.9 N.m for ground reaction moments. The UTJLS is the first of its design type. Controller flexibility and physical design support axis constraints to match traditional testing rigs, absolute motion, and synchronous real-time simulation of multiplanar kinematics, GRFs, and musculotendon forces. System DOFs, range of motion, and speed support future testing of faster maneuvers, various joints, and kinetic chains of two connected joints.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Development of an external controller for a real-time digital simulator
    Irokawa, H
    Fujita, M
    Konishi, H
    Kano, Y
    ICDS'97: SECOND INTERNATIONAL CONFERENCE ON DIGITAL POWER SYSTEM SIMULATORS, PROCEEDINGS, 1997, : 91 - 95
  • [2] Real-time Structure and Motion Recovery from Two Views of a Multiplanar Scene
    Flavio Vigueras-Gomez, Javier
    Sclaroff, Stan
    2011 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION WORKSHOPS (ICCV WORKSHOPS), 2011,
  • [3] Reconfigurable architectures and processors for real-time video motion estimation
    Tiago Dias
    Nuno Roma
    Leonel Sousa
    Miguel Ribeiro
    Journal of Real-Time Image Processing, 2007, 2 : 191 - 205
  • [4] Reconfigurable architectures and processors for real-time video motion estimation
    Dias, Tiago
    Roma, Nuno
    Sousa, Leonel
    Ribeiro, Miguel
    JOURNAL OF REAL-TIME IMAGE PROCESSING, 2007, 2 (04) : 191 - 205
  • [5] INTERACTIVE REAL-TIME MULTIPLANAR CT IMAGING
    NEY, DR
    FISHMAN, EK
    MAGID, D
    KUHLMAN, JE
    RADIOLOGY, 1989, 170 (01) : 275 - 276
  • [6] Novel distributed real-time control system for a target motion simulator
    Hauser, Robin
    Kaegi, Martin
    Gunsch, Dominik
    van Schalkwyk, Mauritz
    Waelti, Peter
    Wegmueller, Christoph
    TECHNOLOGIES FOR SYNTHETIC ENVIRONMENTS: HARDWARE-IN-THE-LOOP XVI, 2011, 8015
  • [7] Reconfigurable microfluidics: real-time shaping of virtual channels through hydrodynamic forces
    Taylor, David P.
    Kaigala, Govind, V
    LAB ON A CHIP, 2020, 20 (10) : 1720 - 1728
  • [8] Real-time intrafraction motion monitoring in external beam radiotherapy
    Bertholet, Jenny
    Knopf, Antje
    Eiben, Bjorn
    McClelland, Jamie
    Grimwood, Alexander
    Harris, Emma
    Menten, Martin
    Poulsen, Per
    Doan Trang Nguyen
    Keall, Paul
    Oelfke, Uwe
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (15):
  • [9] VALIDATION OF A NOVEL IN-VITRO SIMULATOR FOR REAL-TIME CONTROL OF ACTIVE SHOULDER MOVEMENTS IN VARIOUS PLANES OF MOTION
    Giles, J. W.
    Ferreira, L. M.
    Athwal, G. S.
    Johnson, J. A.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [10] Real-Time Prediction of Joint Forces by Motion Capture and Machine Learning
    Giarmatzis, Georgios
    Zacharaki, Evangelia, I
    Moustakas, Konstantinos
    SENSORS, 2020, 20 (23) : 1 - 19