Intensity-based 2-D-3-D registration of cerebral angiograms

被引:106
|
作者
Hipwell, JH [1 ]
Penney, GP
McLaughlin, RA
Rhode, K
Summers, P
Cox, TC
Byrne, JV
Noble, JA
Hawkes, DJ
机构
[1] Guys & St Thomas Hosp, UMDS, Div Imaging Sci, London SE1 9RT, England
[2] Univ Zurich Hosp, Inst Neuroradiol, CH-8091 Zurich, Switzerland
[3] Univ Oxford, Dept Engn Sci, Med Vis Lab, Oxford, England
[4] UCL Natl Hosp Neurol & Neurosurg, Dept Radiol, London WC1N 3BG, England
[5] Univ Oxford, Radcliffe Infirm, Dept Radiol, Oxford OX2 6HE, England
关键词
2-D-3D registration; digital subtraction angiography; magnetic resonance angiography; neuro-interventions; similarity measures;
D O I
10.1109/TMI.2003.819283
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We propose a new method for aligning three-dimensional (3-D) magnetic resonance angiography (MRA) with 2-D X-ray digital subtraction angiograms (I)SA). Our method is developed from our algorithm to register computed tomography volumes to X-ray images based on intensity matching of digitally reconstructed radiographs (DRRs). To make the DSA and DRR more similar, we transform the MRA images to images of the vasculature and set to zero the contralateral side of the MRA to that imaged with DSA. We initialize the search for a match on a user defined circular region of interest. We have tested six similarity measures using both unsegmented MRA and three segmentation variants of the MRA. Registrations were carried out on images of a physical neuro-vascular phantom and images obtained during four neuro-vascular interventions. The most accurate and robust registrations were obtained using the pattern intensity, gradient difference, and gradient correlation similarity measures, when used in conjunction with the most sophisticated MRA segmentations. Using these measures, 95% of the phantom start positions and 82% of the clinical start positions were successfully registered. The lowest root mean square reprojection errors were 1.3 mm (standard deviation 0.6) for the phantom and 1.5 mm (standard deviation 0.9) for the clinical data sets. Finally, we present a novel method for the comparison of similarity measure performance using a technique borrowed from receiver operator characteristic analysis.
引用
收藏
页码:1417 / 1426
页数:10
相关论文
共 50 条
  • [41] A parametric intensity-based 3D image registration method for magnetic resonance imaging
    Huajun Song
    Peihua Qiu
    [J]. Signal, Image and Video Processing, 2017, 11 : 455 - 462
  • [42] Effective intensity-based 2D/3D rigid registration between fluoroscopic X-ray and CT
    Knaan, D
    Joskowicz, L
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 1, 2003, 2878 : 351 - 358
  • [43] Reproduction of forearm rotation dynamic using intensity-based biplane 2D–3D registration matching method
    Ryoya Shiode
    Satoshi Miyamura
    Arisa Kazui
    Natsuki Yamamoto
    Tasuku Miyake
    Toru Iwahashi
    Hiroyuki Tanaka
    Yoshito Otake
    Yoshinobu Sato
    Tsuyoshi Murase
    Shingo Abe
    Seiji Okada
    Kunihiro Oka
    [J]. Scientific Reports, 14
  • [44] Intensity-based 3D/2D registration for percutaneous intervention of major aorto-pulmonary collateral arteries
    Couet, Julien
    Rivest-Henault, David
    Miro, Joaquim
    Lapierre, Chantale
    Duong, Luc
    Cheriet, Mohamed
    [J]. MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [45] Evaluation of intensity-based 2D-3D spine image registration using clinical gold-standard data
    Russakoff', DB
    Rohlfing, T
    Ho, A
    Kim, DH
    Shahidi, R
    Adler, JR
    Maurer, CR
    [J]. BIOMEDICAL IMAGE REGISTRATION, 2003, 2717 : 151 - 160
  • [46] A comparative analysis of intensity-based 2D–3D registration for intraoperative use in pedicle screw insertion surgeries
    Hooman Esfandiari
    Carolyn Anglin
    Pierre Guy
    John Street
    Simon Weidert
    Antony J. Hodgson
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 1725 - 1739
  • [47] On intensity-based 3D visual servoing
    Silveira, Geraldo
    [J]. ROBOTICS AND AUTONOMOUS SYSTEMS, 2014, 62 (11) : 1636 - 1645
  • [48] A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy
    Munbodh, Reshma
    Chen, Zhe
    Jaffray, David A.
    Moseley, Douglas J.
    Knisely, Jonathan P. S.
    Duncan, James S.
    [J]. MEDICAL PHYSICS, 2007, 34 (07) : 3005 - 3017
  • [49] Automatic multimodal 2D/3D breast image registration using biomechanical FEM models and intensity-based optimization
    Hopp, T.
    Dietzel, M.
    Baltzer, P. A.
    Kreisel, P.
    Kaiser, W. A.
    Gemmeke, H.
    Ruiter, N. V.
    [J]. MEDICAL IMAGE ANALYSIS, 2013, 17 (02) : 209 - 218
  • [50] Extension of the ICP algorithm to non-rigid intensity-based registration of 3D volumes
    Feldmar, J
    Malandain, G
    Declerck, J
    Ayache, N
    [J]. PROCEEDINGS OF THE IEEE WORKSHOP ON MATHEMATICAL METHODS IN BIOMEDICAL IMAGE ANALYSIS, 1996, : 84 - 93