The features of electron dose distributions in circular objects: Comparison of Monte Carlo calculation predictions with dosimetry

被引:9
|
作者
Kaluska, I.
Lazurik, V. T.
Lazurik, V. M.
Popov, G.
Rogov, Yu.
Zimek, Z.
机构
[1] Kharkov Natl Univ, UA-61195 Kharkov, Ukraine
[2] Inst Nucl Chem & Technol, PL-03195 Warsaw, Poland
关键词
multi-layer circular objects; Monte Carlo simulation; film dosimetry;
D O I
10.1016/j.radphyschem.2007.03.018
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The features of electron dose field formation in the multi-layer circular objects are related with its surface irregularity such as convexity, concavity and roundness of inner and outer layers. The simulation of dose distributions in multi-layer tubes irradiated with a scanned electron beam (EB) was carried out by Monte Carlo (MC) method with utilization of the software ModeCEB. The effects of mutual influence on dose field formation in contacting multi-layers tubes irradiated with EB were MC simulated and measured with a film dosimetry. An experimental validation of the obtained simulation predictions for dose distributions in multi-layer tubes irradiated with 10MeV electrons was performed on radiation facility with linear electron accelerator LAE 13/9, INCT, Warsaw. Comparison of MC simulation results with a film dosimetry is discussed in the report. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1815 / 1819
页数:5
相关论文
共 50 条
  • [1] MONTE-CARLO CALCULATION OF ELECTRON DEPTH DOSE DISTRIBUTIONS
    SCHRIBER, SO
    FUNK, LW
    MOWCHENKO, JT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 573 - 573
  • [2] Comparison of dose calculation algorithms with Monte Carlo simulation for surface dosimetry
    Chow, J.
    Jiang, R.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4308 - 4308
  • [3] Monte Carlo simulation models for 3-D electron beam dose mapping. Comparison of dose predictions with dosimetry
    Weiss, DE
    Stangeland, RJ
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2003, 66 (03) : 223 - 235
  • [4] Comparison of IMRT verification by means of film dosimetry and Monte Carlo dose calculation
    Gotzfried, T.
    Rickhey, M.
    Treutwein, W.
    Bogner, L.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 28 - 28
  • [5] Validation of Monte Carlo Electron Dose Calculation in RayStation
    Yang, K.
    Chen, H.
    Mourtada, F.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E261 - E261
  • [6] Electron beam commissioning for Monte Carlo dose calculation
    Deng, J
    Jiang, SB
    Pawlicki, T
    Li, JS
    Ma, CM
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 431 - 433
  • [7] Comparison of measured and Monte Carlo calculated dose distributions from circular collimators for radiosurgical beams
    Esnaashari, K. N.
    Allahverdi, M.
    Gharaati, H.
    Shahriari, M.
    [J]. IRANIAN JOURNAL OF RADIATION RESEARCH, 2007, 5 (01): : 31 - 36
  • [8] Comparison of measured and Monte Carlo-calculated electron depth dose distributions in aluminium
    Vandana, S.
    Benny, P. G.
    Selvam, T. Palani
    [J]. INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2018, 56 (01) : 48 - 52
  • [9] A comparison of Monte-Carlo simulated and measured dose distributions in oblique electron beams
    Schweizer, Frederic
    Christ, Gunter
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2010, 20 (01): : 17 - 24
  • [10] A comparison of Monte Carlo dose calculation denoising techniques
    El Naqa, I
    Kawrakow, I
    Fippel, M
    Siebers, JV
    Lindsay, PE
    Wickerhauser, MV
    Vicic, M
    Zakarian, K
    Kauffmann, N
    Deasy, JO
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05): : 909 - 922