A comparison of Monte Carlo dose calculation denoising techniques

被引:26
|
作者
El Naqa, I
Kawrakow, I
Fippel, M
Siebers, JV
Lindsay, PE
Wickerhauser, MV
Vicic, M
Zakarian, K
Kauffmann, N
Deasy, JO
机构
[1] Washington Univ, Sch Med, Div Phys, St Louis, MO 63110 USA
[2] Natl Res Council Canada, Ottawa, ON, Canada
[3] Univ Tubingen, Tubingen, Germany
[4] Virginia Commonwealth Univ, Richmond, VA USA
[5] Ecole Polytech, Palaiseau, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 05期
关键词
D O I
10.1088/0031-9155/50/5/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent studies have demonstrated that Monte Carlo (MC) denoising techniques can reduce MC radiotherapy dose computation time significantly by preferentially eliminating statistical fluctuations ('noise') through smoothing. In this study, we compare new and previously published approaches to MC denoising, including 3D wavelet threshold denoising with sub-band adaptive thresholding, content adaptive mean-median-hybrid (CAMH) filtering, locally adaptive Savitzky-Golay curve-fitting (LASG), anisotropic diffusion (AD) and an iterative reduction of noise (IRON) method formulated as an optimization problem. Several challenging phantom and computed-tomography-based MC dose distributions with varying levels of noise formed the test set. Denoising effectiveness was measured in three ways: by improvements in the mean-square-error (MSE) with respect to a reference (low noise) dose distribution; by the maximum difference from the reference distribution and by the 'Van Dyk' pass/fail criteria of either adequate agreement with the reference image in low-gradient regions (within 2% in our case) or, in high-gradient regions, a distance-to-agreement-within-2% of less than 2 mm. Results varied significantly based on the dose test case: greater reductions in MSE were observed for the relatively smoother phantom-based dose distribution (up to a factor of 16 for the LASG algorithm); smaller reductions were seen for an intensity modulated radiation therapy (IMRT) head and neck case (typically, factors of 2-4). Although several algorithms reduced statistical noise for all test geometries, the LASG method had the best MSE reduction for three of the four test geometries, and performed the best for the Van Dyk criteria. However, the wavelet thresholding method performed better for the head and neck IMRT geometry and also decreased the maximum error more effectively than LASG. In almost all cases, the evaluated methods provided acceleration of MC results towards statistically more accurate results.
引用
收藏
页码:909 / 922
页数:14
相关论文
共 50 条
  • [1] Denoising of Monte Carlo dose distributions
    Deasy, JO
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1494 - 1496
  • [2] Denoising of electron beam Monte Carlo dose distributions using digital filtering techniques
    Deasy, JO
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07): : 1765 - 1779
  • [3] Comparison of dose calculation algorithms with Monte Carlo simulation for surface dosimetry
    Chow, J.
    Jiang, R.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4308 - 4308
  • [4] Comparison of dose calculation algorithms with Monte Carlo methods for photon arcs
    Chow, JCL
    Wong, E
    Chen, JZ
    Van Dyk, J
    [J]. MEDICAL PHYSICS, 2003, 30 (10) : 2686 - 2694
  • [5] Denoising of Monte Carlo Dose Distributions Using UNet
    Javaid, U.
    Souris, K.
    Dasnoy, D.
    Montero, A. Barragan
    Huang, S.
    Lee, J.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E120 - E120
  • [6] Monte Carlo dose calculation on deforming anatomy
    Peterhans, Matthias
    Frei, Daniel
    Manser, Peter
    Aguirre, Mauricio Reyes
    Fix, Michael K.
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (02): : 113 - 123
  • [7] Comparison of IMRT verification by means of film dosimetry and Monte Carlo dose calculation
    Gotzfried, T.
    Rickhey, M.
    Treutwein, W.
    Bogner, L.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 28 - 28
  • [8] Deep learning-based fast denoising of Monte Carlo dose calculation in carbon ion radiotherapy
    Zhang, Xinyang
    Zhang, Hui
    Wang, Jian
    Ma, Yuanyuan
    Liu, Xinguo
    Dai, Zhongying
    He, Rui
    He, Pengbo
    Li, Qiang
    [J]. MEDICAL PHYSICS, 2023, 50 (12) : 7314 - 7323
  • [9] Monte Carlo Calculation of Zinc Oxide Nanoparticles Enhanced Dose & Comparison with Radiochromic Dose Measurements
    Banaee, N.
    Nedaie, H.
    Khezerloo, D.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2908 - 2908
  • [10] Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC
    Kawrakow, I
    Fippel, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : 2163 - 2183