Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory

被引:51
|
作者
Guedon-Moreau, Laurence [1 ]
Chevalier, Philippe [2 ]
Marquie, Christelle [1 ]
Kouakam, Claude [1 ]
Klug, Didier [1 ]
Lacroix, Dominique [1 ]
Brigadeau, Francois [1 ]
Kacet, Salem [1 ]
机构
[1] Ctr Hosp Reg Univ, Hop Cardiol, F-59037 Lille, France
[2] Ctr Hosp Univ, Lyon, France
关键词
Telemedicine; Remote monitoring; Lead failure; Implantable cardioverter-defibrillator; Inappropriate shock; RESYNCHRONIZATION THERAPY SYSTEMS; REDUCE INAPPROPRIATE SHOCKS; FAILURE; HOME; PACEMAKERS; EXPERIENCE; FRACTURE; RECALLS; ALERTS;
D O I
10.1093/eurheartj/ehq203
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Automatic daily transmission of data from implantable cardioverter-defibrillators (ICDs) enables the remote monitoring of device status and leads function. We report on a 2-year experience with remote monitoring in 40 recipients of high-voltage ICD leads, prone to fracture and under advisory since October 2007. The ICDs were remotely monitored as well as systematically interrogated in the ambulatory department every 3 months. The patients were also seen in case of abnormal lead impedance, or other manifestations consistent with lead dysfunction. Over a mean follow-up of 22 +/- 4 months after ICD implantation, four lead dysfunctions were suspected because of remotely transmitted oversensing of noise artifacts, abrupt rise in pacing impedance, or both. A lead fracture needing lead replacement was confirmed in three patients (7.5%), two of them before any inappropriate therapy and one after the delivery of three inappropriate shocks. No lead failure was observed in the remaining 36 patients, either at the time of ambulatory visits or during remote monitoring. Remote monitoring allowed the early and reliable detection of ICD leads failure without requiring any patient intervention.
引用
收藏
页码:2246 / 2252
页数:7
相关论文
共 50 条
  • [21] Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-Up The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) Trial
    Varma, Niraj
    Epstein, Andrew E.
    Irimpen, Anand
    Schweikert, Robert
    Love, Charles
    [J]. CIRCULATION, 2010, 122 (04) : 325 - U28
  • [22] No News is Good News: Remote Monitoring of Implantable Cardioverter-Defibrillator Patients
    Skov, Mikael B.
    Johansen, Pauline G.
    Skov, Charlotte S.
    Lauberg, Astrid
    [J]. CHI 2015: PROCEEDINGS OF THE 33RD ANNUAL CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS, 2015, : 827 - 836
  • [23] Implantable cardioverter defibrillator follow-up: Will office visits be replaced by transtelephonic monitoring?
    Russo, AM
    Nayak, H
    Hsia, H
    Lin, D
    Verdino, R
    Scotti, J
    Ahlemeyer, L
    Marchlinski, FE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 126A - 127A
  • [24] Follow-up of the patient with automatic implantable cardioverter defibrillator
    Cruz Cardentey, Marleny
    Prieto Guerra, Maidelis
    Gutierrez Lopez, Alain
    Mengana Betancourt, Ana
    Ramos Cordero, Michel Y.
    Tannis Wilson, Eko
    Tamargo Barbeito, Teddy O.
    [J]. CORSALUD, 2020, 12 (03): : 283 - 291
  • [25] Remote monitoring follow-up of RIATA defibrillation leads under advisory: is it useful to identify defective leads?
    Zhao, X.
    Thomann, S.
    Alfalasi, O.
    Massin, F.
    Cung, T. T.
    Cransac, F.
    Davy, J. M.
    Pasquie, J. -L.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 100 - 101
  • [26] Risk of Failure of Transvenous Implantable Cardioverter-Defibrillator Leads
    Borleffs, C. Jan Willem
    van Erven, Lieselot
    van Bommel, Rutger J.
    van der Velde, Enno T.
    van der Wall, Ernst E.
    Bax, Jeroen J.
    Rosendaal, Frits R.
    Schalij, Martin J.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (04): : 411 - 416
  • [27] Remote monitoring provides feasible and time-saving means for follow-up of patients with implantable cardioverter defibrillator
    Raatikainen, Pekka
    Uusimaa, Paavo
    Linnaluoto, Markku
    Sieben, Inge
    Janssen, Jacques
    Murthy, Anant
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 119 : S5 - S6
  • [28] Insulation Defects in Riata Implantable Cardioverter-defibrillator Leads
    Sato, Akinori
    Chinushi, Masaomi
    Iijima, Kenichi
    Izumi, Daisuke
    Furushima, Hiroshi
    [J]. INTERNAL MEDICINE, 2012, 51 (19) : 2689 - 2694
  • [29] Implantable Cardioverter-Defibrillator Leads Design, Diagnostics, and Management
    Swerdlow, Charles D.
    Ellenbogen, Kenneth A.
    [J]. CIRCULATION, 2013, 128 (18) : 2062 - 2071
  • [30] LAPAROSCOPIC PLACEMENT OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEADS IN SHEEP
    BIELEFELD, MR
    YANO, OJ
    CABRERIZA, SE
    TREAT, MR
    KIRBY, TJ
    SPOTNITZ, HM
    [J]. CIRCULATION, 1992, 86 (04) : 569 - 569