Safety and effectiveness of do-it-yourself artificial pancreas system compared with continuous subcutaneous insulin infusions in combination with free style libre in people with type 1 diabetes

被引:11
|
作者
Patel, Rachel [1 ]
Crabtree, Thomas S. J. [2 ,3 ]
Taylor, Nicola [2 ]
Langeland, Linn [2 ]
Gazis, Anastasios [4 ]
Mendis, Buddhike [4 ]
Wilmot, Emma G. [2 ,3 ]
Idris, Iskandar [2 ,5 ,6 ]
机构
[1] Univ Nottingham, Sch Med, Nottingham, England
[2] Univ Hosp Derby & Burton NHS Trust, Royal Derby Hosp, Dept Diabet & Endocrinol, Derby, England
[3] Univ Nottingham, Div Grad Entry Med & Hlth Sci, Nottingham, England
[4] Nottingham Univ Hosp, Queens Med Ctr, Dept Diabet & Endocrinol, Nottingham, England
[5] Univ Nottingham, MRC Versus Arthrit Ctr Musculoskeletal Ageing Res, Nottingham, England
[6] Univ Nottingham, Nottingham BRC, NIHR, Nottingham, England
关键词
continuous subcutaneous insulin infusion; do it your self artificial pancreas system (DIYAPS); Freestyle Libre; type; 1; diabetes; MULTIPLE DAILY INJECTIONS; GLYCEMIC CONTROL; SEVERE HYPOGLYCEMIA; COMPLICATIONS;
D O I
10.1111/dme.14793
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The use of do-it-yourself artificial pancreas systems (DIYAPS) among people with type 1 diabetes is increasing. At present, it is unclear how DIYAPS compares with other technologies such as FreeStyle Libre (FSL) and continuous subcutaneous insulin infusion (CSII). The aim of this analysis is to compare safety, effectiveness and quality-of-life outcomes of DIYAPS use with the addition of FSL to CSII. Method Data from two large UK hospitals were extracted from the Association of British Clinical Diabetologists (ABCD) DIYAPS and FSL audits. Outcomes included HbA(1c), glucose TBR (time-below-range), TIR (time-in-range), Diabetes Distress Score (DDS), and Gold hypoglycaemia score. Any adverse events were noted. Changes at follow-up were assessed using paired t-tests and ANOVA in Stata; TIR/TBR at follow-up assessed using unpaired t-tests; chi-square tests assessed the change in frequency of health utilisation (e.g. hospital admissions). Results DIYAPS (n = 35) and FSL+CSII (n = 149) users, with median follow-up duration of 1.4 (IQR 0.8-2.1) and 1.3 (IQR 0.7-1.8) years, respectively, were included. HbA(1c) with DIYAPS use changed by -10 mmol/mol [0.9%] (p < 0.001, 95% CI 5, 14 [0.5, 1.3%]) significantly lower (p < 0.001) than in the FSL+CSII group -3 mmol/mol [0.25%] (p < 0.001, 95% CI 1, 4 [0.1, 0.4%]). TIR was higher and TBR was lower in the DIYAPS group. Adverse events were rare in both groups and no significant differences were observed in the frequency of healthcare utilisation. Conclusion DIYAPS use was associated with a lower HbA(1c) levels, higher TIR and lower TBR compared with FSL+CSII. There was no significant increase in adverse events, although this should be interpreted cautiously given the low numbers of users. Full results from the ABCD DIYAPS audit are awaited.
引用
收藏
页数:7
相关论文
共 49 条
  • [31] Real-World Use of Do-It-Yourself Artificial Pancreas Systems in Children and Adolescents With Type 1 Diabetes: Online Survey and Analysis of Self-Reported Clinical Outcomes
    Braune, Katarina
    O'Donnell, Shane
    Cleal, Bryan
    Lewis, Dana
    Tappe, Adrian
    Willaing, Ingrid
    Hauck, Bastian
    Raile, Klemens
    JMIR MHEALTH AND UHEALTH, 2019, 7 (07):
  • [32] Changes in Ambulatory Glucose Profile in Patients With Type 1 Diabetes Mellitus After Switching From Sensor-Augmented Insulin Pump Therapy to a Do-It-Yourself Artificial Pancreas System: A Retrospective Data Analysis of Real-World Data
    Mueller-Korbsch, Michael
    Fruehwald, Lisa
    Kietaibl, Antonia
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (06): : 1577 - 1579
  • [33] Patient Values and Preferences Regarding Continuous Subcutaneous Insulin Infusion and Artificial Pancreas in Adults with Type 1 Diabetes: A Systematic Review of Quantitative and Qualitative Data
    Munoz-Velandia, Oscar
    Guyatt, Gordon
    Devji, Tahira
    Zhang, Yuan
    Li, Shelly-Anne
    Alexander, Paul Elias
    Henao, Diana
    Gomez, Ana-Maria
    Ruiz-Morales, Alvaro
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (04) : 183 - 200
  • [34] Changes in Ambulatory Glucose Profile (AGP) in Patients with Type 1 Diabetes Mellitus after Switching from Sensor-Augmented Insulin Pump Therapy to a Do-it-Yourself Artificial Pancreas System: A Retrospective Data Analysis of Real-World Data
    Mueller-Korbsch, Michael
    Fruehwald, Lisa
    Kietaibl, Antonia-Therese
    DIABETES, 2022, 71
  • [35] COST-EFFECTIVENESS ANALYSIS OF SENSOR-AUGMENTED PUMP IN TYPE 1 DIABETES MELLITUS COMPARED WITH CONTINUOUS SUBCUTANEOUS INSULIN INFUSION IN THE RUSSIAN FEDERATION
    Yagudina, R.
    Kulikov, A.
    Serpik, V
    Kostina, E.
    VALUE IN HEALTH, 2020, 23 : S115 - S115
  • [36] Safety and Efficacy of Initializing the Control-IQ Artificial Pancreas System Based on Total Daily Insulin in Adolescents with Type 1 Diabetes
    Schoelwer, Melissa J.
    Robic, Jessica L.
    Gautier, Thibault
    Fabris, Chiara
    Carr, Kelly
    Clancy-Oliveri, Mary
    Brown, Sue A.
    Anderson, Stacey M.
    DeBoer, Mark D.
    Chernavvsky, Daniel R.
    Breton, Marc D.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (08) : 594 - 601
  • [37] Effectiveness and Safety of an Advanced Hybrid Closed-Loop System in Adolescents and Adults with Type 1 Diabetes Previously Treated with Continuous Subcutaneous Insulin Infusion and Flash Glucose Monitoring
    Herguido, Noelia Gros
    Amuedo, Sandra
    Bellido, Virginia
    Gallardo, Gema Lopez
    Losada, Fernando
    Morales, Ana Perez
    Trillo, Carmen Amelia Ruiz
    Moreno, Alfonso Soto
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 (02) : 151 - 156
  • [38] Open Source Artificial Pancreas System (APS) vs. Combination Insulin Pump with Flash Glucose Monitoring in Adults with Type 1 Diabetes: An Observational Study
    Wilmot, Emma G.
    Langeland, Linn
    Mclay, Alasdair
    Taylor, Nicola
    Idris, Iskandar Rauf
    DIABETES, 2019, 68
  • [39] COST EFFECTIVENESS ANALYSIS OF MINIMEDTM 670G SYSTEM VERSUS CONTINUOUS SUBCUTANEOUS INSULIN INFUSION, IN INDIVIDUALS WITH TYPE1 DIABETES IN THE UNITED KINGDOM
    Roze, S.
    Buompensiere, I.
    Saltik, Z. Ozdemir
    Cohen, O.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A83 - A83
  • [40] Effectiveness and safety of a model predictive control (MPC) algorithm for an artificial pancreas system in outpatients with type 1 diabetes ( T1D): systematic review and meta-analysis
    Kang, Su Lim
    Hwang, Yoo Na
    Kwon, Ji Yean
    Kim, Sung Min
    DIABETOLOGY & METABOLIC SYNDROME, 2022, 14 (01):