Safety and effectiveness of do-it-yourself artificial pancreas system compared with continuous subcutaneous insulin infusions in combination with free style libre in people with type 1 diabetes

被引:11
|
作者
Patel, Rachel [1 ]
Crabtree, Thomas S. J. [2 ,3 ]
Taylor, Nicola [2 ]
Langeland, Linn [2 ]
Gazis, Anastasios [4 ]
Mendis, Buddhike [4 ]
Wilmot, Emma G. [2 ,3 ]
Idris, Iskandar [2 ,5 ,6 ]
机构
[1] Univ Nottingham, Sch Med, Nottingham, England
[2] Univ Hosp Derby & Burton NHS Trust, Royal Derby Hosp, Dept Diabet & Endocrinol, Derby, England
[3] Univ Nottingham, Div Grad Entry Med & Hlth Sci, Nottingham, England
[4] Nottingham Univ Hosp, Queens Med Ctr, Dept Diabet & Endocrinol, Nottingham, England
[5] Univ Nottingham, MRC Versus Arthrit Ctr Musculoskeletal Ageing Res, Nottingham, England
[6] Univ Nottingham, Nottingham BRC, NIHR, Nottingham, England
关键词
continuous subcutaneous insulin infusion; do it your self artificial pancreas system (DIYAPS); Freestyle Libre; type; 1; diabetes; MULTIPLE DAILY INJECTIONS; GLYCEMIC CONTROL; SEVERE HYPOGLYCEMIA; COMPLICATIONS;
D O I
10.1111/dme.14793
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The use of do-it-yourself artificial pancreas systems (DIYAPS) among people with type 1 diabetes is increasing. At present, it is unclear how DIYAPS compares with other technologies such as FreeStyle Libre (FSL) and continuous subcutaneous insulin infusion (CSII). The aim of this analysis is to compare safety, effectiveness and quality-of-life outcomes of DIYAPS use with the addition of FSL to CSII. Method Data from two large UK hospitals were extracted from the Association of British Clinical Diabetologists (ABCD) DIYAPS and FSL audits. Outcomes included HbA(1c), glucose TBR (time-below-range), TIR (time-in-range), Diabetes Distress Score (DDS), and Gold hypoglycaemia score. Any adverse events were noted. Changes at follow-up were assessed using paired t-tests and ANOVA in Stata; TIR/TBR at follow-up assessed using unpaired t-tests; chi-square tests assessed the change in frequency of health utilisation (e.g. hospital admissions). Results DIYAPS (n = 35) and FSL+CSII (n = 149) users, with median follow-up duration of 1.4 (IQR 0.8-2.1) and 1.3 (IQR 0.7-1.8) years, respectively, were included. HbA(1c) with DIYAPS use changed by -10 mmol/mol [0.9%] (p < 0.001, 95% CI 5, 14 [0.5, 1.3%]) significantly lower (p < 0.001) than in the FSL+CSII group -3 mmol/mol [0.25%] (p < 0.001, 95% CI 1, 4 [0.1, 0.4%]). TIR was higher and TBR was lower in the DIYAPS group. Adverse events were rare in both groups and no significant differences were observed in the frequency of healthcare utilisation. Conclusion DIYAPS use was associated with a lower HbA(1c) levels, higher TIR and lower TBR compared with FSL+CSII. There was no significant increase in adverse events, although this should be interpreted cautiously given the low numbers of users. Full results from the ABCD DIYAPS audit are awaited.
引用
收藏
页数:7
相关论文
共 49 条
  • [1] Hybrid Closed Loop Using a Do-It-Yourself Artificial Pancreas System in Adults With Type 1 Diabetes
    Nanayakkara, Natalie
    Sharifi, Amin
    Burren, David
    Elghattis, Yasser
    Jayarathna, Dulari K.
    Cohen, Neale
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (04): : 889 - 896
  • [2] Analysis of "Hybrid Closed Loop Using a Do-It-Yourself Artificial Pancreas System in Adults With Type 1 Diabetes"
    Wilkinson, Tom M.
    de Bock, Martin
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (04): : 897 - 898
  • [3] Corrigendum to "Hybrid Closed Loop Using a Do-It-Yourself Artificial Pancreas System in Adults With Type 1 Diabetes"
    不详
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (06): : 1523 - 1523
  • [4] Impact of Custom Features of Do-it-yourself Artificial Pancreas Systems (DIYAPS) on Glycemic Outcomes of People with Type 1 Diabetes
    Staszak, Wiktoria
    Chromik, Jonas
    Braune, Katarina
    Arnrich, Bert
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 1472 - 1475
  • [5] Safety and Glucose Control with "Do It Yourself Android Artificial Pancreas System" Using Freestyle Libre Sensor plus MiaoMiao in Patients with Type 1 Diabetes
    Dantas, Maria Eduarda P.
    Messias, Laryssa D. S.
    Ventura, Gabriella L.
    Machado, Maria De Lourdes
    Souto, Debora L.
    Dantas, Joana R.
    Soares, Thiago M.
    Santos, Edson P.
    Oliveira, Tassia
    Zajdenverg, Lenita
    Rodacki, Melanie
    DIABETES, 2024, 73
  • [6] Real-World Use of Do-It-Yourself Artificial Pancreas Systems in Adults with Type 1 Diabetes
    Amuedo, Sandra
    Antequera, Maria
    Azriel, Sharona
    DIABETES, 2022, 71
  • [7] Do-It-Yourself Artificial Pancreas Systems for Type 1 Diabetes Reduce Hyperglycemia without Increasing Hypoglycemia
    Zabinsky, Jennifer
    Howell, Haley
    Ghezavati, Alireza
    Lewis, Dana M.
    Nguyen, Andrew
    Wong, Jenise C.
    DIABETES, 2020, 69
  • [8] A scoping review of Do-It-Yourself Automated Insulin Delivery system (DIY AID) use in people with type 1 diabetes
    Morrison, Amy E.
    Chong, Kimberley
    Senior, Peter A.
    Lam, Anna
    PLOS ONE, 2022, 17 (08):
  • [9] Do-It-Yourself Open Artificial Pancreas System in Children and Adolescents with Type 1 Diabetes Mellitus: Real-World Data
    Choi, Min Sun
    Lee, Seunghyun
    Kim, Jiwon
    Kim, Gyuri
    Park, Sung Min
    Kim, Jae Hyeon
    DIABETES & METABOLISM JOURNAL, 2022, 46 (01) : 154 - +
  • [10] Do-It-Yourself Artificial Pancreas Systems in Type 1 Diabetes: Perspectives of Two Adult Users, a Caregiver and Three Physicians
    Marshall, Dominic C.
    Holloway, Melissa
    Korer, Mendy
    Woodman, James
    Brackenridge, Anna
    Hussain, Sufyan
    DIABETES THERAPY, 2019, 10 (05) : 1553 - 1564