From crash test to the operating room: optimization of stent-graft design using numerical simulation

被引:1
|
作者
Kliewer, Miriam Elisabeth [1 ]
Taher, Fadi [1 ]
Falkensammer, Juergen [2 ]
Millon, Antoine [3 ]
Albertini, Jean-Noel [4 ]
Assadian, Afshin [1 ]
机构
[1] Klin Ottakring, Abt Gefass Vaskulare & Endovaskulare Chirurg, Montleartstr 37 Pav 30b, A-1160 Vienna, Austria
[2] Konventspital Linz, Abt Gefass Chirurg, Barmherzige Bruder, Linz, Austria
[3] CHU Lyon, Hosp Louis Pradel, Abt Gefasschirurg & Endovaskulare Chirurg, Lyon, France
[4] CHU St Etienne, Abt Gefasschirurg, St Etienne, France
来源
GEFASSCHIRURGIE | 2022年 / 27卷 / 05期
关键词
Complex aortic aneurysm; Fenestrated endovascular aneurysm repair; Numerical simulation; Finite element analysis; Preoperative testing; DEPLOYMENT;
D O I
10.1007/s00772-022-00921-1
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Numerical simulation (NS) is a computer-based procedure to simulate and demonstrate mechanical interactions between bodies. It is well known and has been used in the automotive and aerospace industries for years. The method of NS is also used in the field of endovascular surgery to predict the behavior of stent-grafts in vessels and to plan complex custom-made prostheses. Objective: The current planning and manufacture of fenestrated prostheses for complex aortic aneurysms is a time, human resources and material intensive process, which for most manufacturers takes weeks to months. The positioning of fenestrations should be as accurate as possible to enable a successful and complication-free implantation. A precise prediction of graft deployment and alignment within the patient's aorta has so far only been possible to a certain extent in models. Methods: Numerical simulation using finite element analysis now enables this prediction. The mechanical properties of the stent-graft and the aorta can be implemented and graft deployment can be simulated and graphically shown in a patient-specific aorta. In this way, the optimal dimensions of the prosthesis can be determined and the fenestrations can be exactly positioned. The computed tomography (CT) angiography of the complete aorta in 1 mm thick slices serves as input data. Based on the CT data a digital twin of the aorta is simulated and presented 3-dimensionally. In this hollow model the prosthesis, which is not yet fenestrated, is digitally implanted and in the next step the positions of the fenestrations are then determined based on the ostia of the visceral arteries. Results: The results of a prospective multicenter study showed that planning fenestrated grafts using NS is accurate and time saving compared to the conventional planning process. Moreover, a user-friendly online platform has already been developed, which in the future will enable a complex custom-made graft planning within 24 h. The 3-dimensional depiction of the unfolded prosthesis can be assessed in all directions and possible problems can be predicted and therefore rectified. Discussion: The development of digital planning of a prosthesis and prediction of the unfolding of a stent-graft within the patient's aorta is an important step towards a contemporary, fast and safe treatment of patients with complex aortic aneurysms.
引用
收藏
页码:342 / 348
页数:7
相关论文
共 50 条
  • [21] Failure Behavior of Room and Pillar with Different Room Configuration Under Uniaxial Loading Using Experimental Test and Numerical Simulation
    Sarfarazi, Vahab
    Fattahi, Shahin
    Asgari, Kaveh
    Bahrami, Reza
    Wang, Xiao
    GEOTECHNICAL AND GEOLOGICAL ENGINEERING, 2022, 40 (06) : 2881 - 2896
  • [22] Optimization of Capacitive Acoustic Resonant Sensor Using Numerical Simulation and Design of Experiment
    Haque, Rubaiyet Iftekharul
    Loussert, Christophe
    Sergent, Michelle
    Benaben, Patrick
    Boddaert, Xavier
    SENSORS, 2015, 15 (04) : 8945 - 8967
  • [23] Design and optimization of an ultrasonic flexural plate wave micropump using numerical simulation
    Nguyen, NT
    White, RM
    SENSORS AND ACTUATORS A-PHYSICAL, 1999, 77 (03) : 229 - 236
  • [24] Endovascular Repair of Abdominal Aortic Aneurysm using Bifurcated Stent-graft in a Patient with Complete Occlusion from the Common to the External Iliac Artery
    Fujimura, Naoki
    Harada, Hirohisa
    Yashiro, Hideki
    Akiyoshi, Takurin
    Nakagawa, Motohito
    Kanai, Toshio
    Obara, Hideaki
    Kitagawa, Yuko
    ANNALS OF VASCULAR SURGERY, 2014, 28 (03) : 740.e1 - 740.e5
  • [25] Optimization of furnace design and growth parameters for Si Cz growth, using numerical simulation
    Smirnova, O. V.
    Durnev, N. V.
    Shandrakova, K. E.
    Mizitov, E. L.
    Soklakov, V. D.
    JOURNAL OF CRYSTAL GROWTH, 2008, 310 (7-9) : 2185 - 2191
  • [26] Resin transfer molding process optimization using numerical simulation and design of experiments approach
    Gou, JH
    Zhang, C
    Liang, ZY
    Wang, B
    Simpson, J
    POLYMER COMPOSITES, 2003, 24 (01) : 1 - 12
  • [27] Design and Parametric Optimization of the Injection Molding Process Using Statistical Analysis and Numerical Simulation
    Chen, Jinping
    Cui, Yanmei
    Liu, Yuanpeng
    Cui, Jianfeng
    PROCESSES, 2023, 11 (02)
  • [28] Using an integrative mock-up simulation approach for evidence-based evaluation of operating room design prototypes
    Bayramzadeh, Sara
    Joseph, Anjali
    Allison, David
    Shultz, Jonas
    Abernathy, James
    APPLIED ERGONOMICS, 2018, 70 : 288 - 299
  • [29] Analysis of external latch-up protection test structure design using numerical simulation
    Palser, K
    Concannon, A
    Duffy, R
    Mathewson, A
    MICROELECTRONICS RELIABILITY, 1999, 39 (05) : 647 - 659
  • [30] Multi-parameter optimization design, numerical simulation and performance test of mixed-flow pump impeller
    Hao Bing
    ShuLiang Cao
    Science China Technological Sciences, 2013, 56 : 2194 - 2206