Inter- and Intra-Rater Reliability of the Visual Vertical in Subacute Stroke

被引:12
|
作者
Piscicelli, Celine [1 ,2 ]
Barra, Julien [3 ]
Davoine, Patrice [1 ]
Chrispin, Anne [1 ]
Nadeau, Sylvie [4 ]
Perennou, Dominic [1 ,2 ]
机构
[1] Clin MPR CHU, Grenoble, France
[2] Grenoble Univ, CNRS, UMR 5105, Lab Psychol & Neurocognit, Grenoble, France
[3] Univ Paris 05, EA7326, Lab Vis, Act Cognit, Paris, France
[4] Univ Montreal, CRIR, Ecole Readaptat, Quebec City, PQ, Canada
关键词
posture; rehabilitation; reliability; stroke; HEMISPHERIC STROKE; PERCEPTION; NEGLECT; LESIONS;
D O I
10.1161/STROKEAHA.115.009610
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose Visual vertical (VV) has been used increasingly as a routine clinical assessment to identify alteration of verticality perception as a possible cause of postural disorders after stroke. This study aims to determine whether the reliability of VV is sufficient to support a wide clinical use in neurorehabilitation for monitoring of patients with stroke. Methods Twenty patients with subacute stroke in neurorehabilitation unit were tested after a first and unique hemispheric stroke. To evaluate the inter-rater reliability, VV was assessed the same day by 2 examiners whose degrees of expertise differed. The second examiner repeated the test the next day to investigate intrarater reliability. VV orientation (mean, primary criterion) and uncertainty (SD, secondary criterion) were calculated for 10 trials. Their reliability was quantified by the intraclass correlation coefficient, Bland-Altman plots, and the minimal detectable change. The concordance between 2 examiners was quantified by Cohen's coefficients (). Results About VV orientation, inter- and intrarater reliability were excellent (intraclass correlation coefficient, 0.979 and 0.982). The Bland-Altman plots and the minimal detectable change revealed a difference inferior to 2 degrees between 2 tests. The concordance between 2 assessments for the diagnosis of abnormal VV orientation was absolute for the same examiner (=1; P<0.05) and excellent between 2 examiners (=0.92; P<0.05). As for VV uncertainty the intrarater reliability was satisfactory (intraclass correlation coefficient, 0.836) but the inter-rater reliability was poor (intraclass correlation coefficient, 0.211). Conclusions The orientation of the VV is a highly reliable criterion, which may be used both in research and in routine clinical practice.
引用
收藏
页码:1979 / 1983
页数:5
相关论文
共 50 条
  • [31] Achalasia Subtypes: an Assessment of Inter- And Intra-Rater Reproducibility
    Hernandez, Jose C.
    Crowell, Michael D.
    Kim, Hack J.
    Ratuapli, Shiva K.
    Burdick, George E.
    DiBaise, John K.
    [J]. GASTROENTEROLOGY, 2010, 138 (05) : S143 - S143
  • [32] Intra-rater and inter-rater reliability of pressure pain threshold assessment in stroke patients
    Zhang, Yong-Hui
    Wang, Yu-Chen
    Hu, Gong-Wei
    Ding, Xiao-Qin
    Shen, Xiao-Hua
    Ng, Hui Ya
    Rong, Ji-Feng
    Wang, Xue-Qiang
    [J]. EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (04) : 549 - 557
  • [33] Inter- and Intra-rater Reliability in Lithic Analysis: a Case Study in Handedness Determination Methodologies
    Lana Ruck
    Chloe Holden
    Shelby S. J. Putt
    Kathy Schick
    Nicholas Toth
    [J]. Journal of Archaeological Method and Theory, 2020, 27 : 220 - 244
  • [34] Inter- and intra-rater reliability of the Fremantle score: a validated method of describing video laryngoscopy
    Ramadas, R.
    Swann, A.
    English, J.
    O'Loughlin, E.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (06) : E900 - E901
  • [35] Inter- and Intra-rater Reliability in Lithic Analysis: a Case Study in Handedness Determination Methodologies
    Ruck, Lana
    Holden, Chloe
    Putt, Shelby S. J.
    Schick, Kathy
    Toth, Nicholas
    [J]. JOURNAL OF ARCHAEOLOGICAL METHOD AND THEORY, 2020, 27 (02) : 220 - 244
  • [36] Inter- and intra-rater reliability of the head-shaft angle in children with cerebral palsy
    Hermanson, M.
    Hagglund, G.
    Riad, J.
    Rodby-Bousquet, E.
    [J]. JOURNAL OF CHILDRENS ORTHOPAEDICS, 2017, 11 (04) : 256 - 262
  • [37] The topical niacin sensitivity test: An inter- and intra-rater reliability study in healthy controls
    Kerr, Melissa
    Cotton, Sue
    Proffitt, Tina
    McConchie, Mirabel
    Markulev, Connie
    Smesny, Stefan
    McGorry, Patrick
    Berger, Gregor
    [J]. PROSTAGLANDINS LEUKOTRIENES AND ESSENTIAL FATTY ACIDS, 2008, 79 (1-2): : 15 - 19
  • [38] The inter and intra-rater reliability of the Comprehensive Oral Assessment Tool for Stroke (COATS)
    Dickinson, H. A.
    Lightbody, C. E.
    Crean, S.
    Watkins, C. L.
    [J]. INTERNATIONAL JOURNAL OF STROKE, 2018, 13 : 33 - 33
  • [39] Test-retest, inter- and intra-rater reliability of the flexicurve for evaluation of the spine in children
    Sedrez, Juliana A.
    Candotti, Claudia T.
    Rosa, Maria I. Z.
    Medeiros, Fernanda S.
    Marques, Mariana T.
    Loss, Jefferson F.
    [J]. BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2016, 20 (02) : 142 - 147
  • [40] INTER- AND INTRA-RATER RELIABILITY OF EEG INTERPRETATION: A LARGE, SINGLE-CENTER STUDY
    Abdel-Baki, S. G.
    Omurtag, A.
    Weedon, J.
    Lushbough, C. A.
    Chari, G.
    Koziorynska, E.
    Maus, D.
    Mcsween, T.
    Mortati, K. A.
    Reznikov, A.
    Arnedo, V.
    Grant, A. C.
    [J]. EPILEPSIA, 2012, 53 : 130 - 130