Environmentally Friendly, Energy-saving Air-conditioning System

被引:0
|
作者
Haneda, Tomoaki [1 ]
机构
[1] Fujitsu Ltd, Design & Consultancy Serv Facil, Customers Data Ctr, Tokyo, Japan
来源
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Amid the recession, it is said that business operators will tend to outsource more and more so that they can gather their IT resources in one place, improve their efficiency and reduce their costs. Data centers are at the heart of this outsourcing, and they consume a large amount of electricity. They need to use electricity safely and efficiently. Against this social background, a new annex of the Tatebayashi System Center, located in Gunma Prefecture in Japan, has implemented an energy-saving air-conditioning system as a measure to try to reduce its environmental impact. This paper introduces an outline of this measure to optimize air conditioning implemented in the server room, based on the cooling method for greening that has been newly introduced this time. In addition, it introduces the effect of the measure that makes the best use of the advantages of scale at the data center.
引用
下载
收藏
页码:383 / 388
页数:6
相关论文
共 50 条
  • [1] Discussion to energy-saving design of the air-conditioning system
    Qian, Wang
    Rui, Li
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3, 2013, 361-363 : 444 - 447
  • [2] An Energy-Saving Control Strategy on Central Air-Conditioning System
    Sheng Xing 1
    Electricity, 2011, 22 (04) : 62 - 66
  • [3] An Energy-Saving Air-Conditioning System Based on Liquid Desiccant
    Wen, Cai
    Zhang, XiaoSong
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 230 - 236
  • [4] Energy-saving Technology of Refrigeration and Air-conditioning
    王玉鹏
    罗展雄
    谭琴
    装备制造技术, 2008, (10) : 24 - 26
  • [5] Energy-saving and optimisation of investments in air-conditioning
    Barta, J
    TELESCON 97, BUDAPEST - THE SECOND INTERNATIONAL TELECOMMUNICATIONS ENERGY SPECIAL CONFERENCE, 1997, : 373 - 377
  • [6] The Experimental Research on Beijing Subway Air-Conditioning System Energy-Saving
    Zhang, Weiya
    Wei, Jun
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 2494 - 2498
  • [7] Sensor network and its energy-saving application for air-conditioning system
    1600, Institute of Electrical Engineers of Japan, 1-12-1 Yurakucho, Chiyoda-ku, Tokyo, 100, Japan (133):
  • [8] Numerical analysis of an air-conditioning energy-saving mechanism
    Huang, K. David
    Nguyen Anh Tuan
    BUILDING SIMULATION, 2010, 3 (01) : 63 - 73
  • [9] Energy-saving technology of air-conditioning systems for datacenters
    Udagawa, Y., 1600, Nippon Telegraph and Telephone Corp. (12):
  • [10] The Central Air-conditioning Energy-saving Control Technology
    Lei, Debao
    Tang, Zhonghua
    Zhao, Kai
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 2695 - +