A Review on Indoor Environment Quality of Indian School Classrooms

被引:25
|
作者
Kapoor, Nishant Raj [1 ,2 ,3 ]
Kumar, Ashok [1 ,2 ,3 ]
Alam, Tabish [2 ,3 ]
Kumar, Anuj [2 ,3 ]
Kulkarni, Kishor S. [1 ,3 ]
Blecich, Paolo [4 ]
机构
[1] CSIR Cent Bldg Res Inst, Architecture & Planning Dept, Roorkee 247667, Uttar Pradesh, India
[2] CSIR Cent Bldg Res Inst, Bldg Energy Efficiency Div, Roorkee 247667, Uttar Pradesh, India
[3] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
[4] Univ Rijeka, Fac Engn, Rijeka 51000, Croatia
关键词
classroom; ventilation; COVID-19; indoor air pollution; sick building syndrome; artificial intelligence; thermal comfort; visual comfort; acoustic comfort; indoor air quality; ARTIFICIAL NEURAL-NETWORK; SIMULATION-BASED OPTIMIZATION; NATURALLY VENTILATED SCHOOLS; VISUAL COMFORT ASSESSMENTS; OCCUPANTS THERMAL COMFORT; MEAN RADIANT TEMPERATURE; FINE PARTICULATE MATTER; SICK BUILDING SYNDROME; HUMAN METABOLIC-RATE; AIR-QUALITY;
D O I
10.3390/su132111855
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The progress of Indoor Environmental Quality (IEQ) research in school buildings has increased profusely in the last two decades and the interest in this area is still growing worldwide. IEQ in classrooms impacts the comfort, health, and productivity of students as well as teachers. This article systematically discusses IEQ parameters related to studies conducted in Indian school classrooms during the last fifteen years. Real-time research studies conducted on Indoor Air Quality (IAQ), Thermal Comfort (TC), Acoustic Comfort (AcC), and Visual Comfort (VC) in Indian school classrooms from July 2006 to March 2021 are considered to gain insight into the existing research methodologies. This review article indicates that IEQ parameter studies in Indian school buildings are tortuous, strewn, inadequate, and unorganized. There is no literature review available on studies conducted on IEQ parameters in Indian school classrooms. The results infer that in India, there is no well-established method to assess the indoor environmental condition of classrooms in school buildings to date. Indian school classrooms are bleak and in dire need of energy-efficient modifications that maintain good IEQ for better teaching and learning outcomes. The prevailing COVID-19 Pandemic, Artificial Intelligence (AI), National Education Policy (NEP), Sick Building Syndrome (SBS), Internet of Things (IoT), and Green Schools (GS) are also discussed to effectively link existing conditions with the future of IEQ research in Indian school classrooms.
引用
收藏
页数:43
相关论文
共 50 条
  • [31] Review on the research of indoor environment quality and building energy consumption
    Yang, Xue-bin
    Gu, Zhi-pan
    Yang, Ji-chun
    Lin, Guang-ping
    ADVANCES IN CIVIL ENGINEERING, PTS 1-4, 2011, 90-93 : 3043 - 3046
  • [32] Indoor air quality modeling for PM10, PM2.5, and PM1.0 in naturally ventilated classrooms of an urban Indian school building
    Radha Goyal
    Mukesh Khare
    Environmental Monitoring and Assessment, 2011, 176 : 501 - 516
  • [33] Indoor Environmental Quality towards Classrooms' Comforts Level: Case Study at Malaysian Secondary School Building
    Norazman, Norsafiah
    Ani, Adi Irfan Che
    Ismail, Wan Norisma Wan
    Hussain, Afifuddin Husairi
    Maulud, Khairul Nizam Abdul
    APPLIED SCIENCES-BASEL, 2021, 11 (13):
  • [34] Indoor air quality modeling for PM10, PM2.5, and PM1.0 in naturally ventilated classrooms of an urban Indian school building
    Goyal, Radha
    Khare, Mukesh
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2011, 176 (1-4) : 501 - 516
  • [35] A study on PM10 and VOCs concentrations of indoor environment in school and recognition of indoor air quality
    Son, BS
    Song, MR
    Yang, WH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 827 - 832
  • [36] Evaluating the risk of mixtures in the indoor air of primary school classrooms
    Nitika Mishra
    Godwin A. Ayoko
    Tunga Salthammer
    Lidia Morawska
    Environmental Science and Pollution Research, 2015, 22 : 15080 - 15088
  • [37] Indoor Air Quality and Bioaerosols in Spanish University Classrooms
    Fuentes-Ferragud, Esther
    Lopez, Antonio
    Piera, Juan Miguel
    Yusa, Vicent
    Garrigues, Salvador
    de la Guardia, Miguel
    Labrador, F. Xavier Lopez
    Camaro, Marisa
    Ibanez, Maria
    Coscolla, Clara
    TOXICS, 2024, 12 (03)
  • [38] Indoor allergen exposure in primary school classrooms in New Zealand
    Siebers, Rob
    Jones, Bernadette
    Bailey, Lauren
    Aldridge, Daniel
    Draper, Jessica
    Ingham, Tristram
    NEW ZEALAND MEDICAL JOURNAL, 2019, 132 (1495) : 42 - 47
  • [39] Evaluating the risk of mixtures in the indoor air of primary school classrooms
    Mishra, Nitika
    Ayoko, Godwin A.
    Salthammer, Tunga
    Morawska, Lidia
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (19) : 15080 - 15088
  • [40] Indoor environmental quality of classrooms in Southern European climate
    Almeida, Ricardo M. S. F.
    de Freitas, Vasco Peixoto
    ENERGY AND BUILDINGS, 2014, 81 : 127 - 140