DESIGN AND EXPERIMENTAL RESEARCH ON THE COMBINED FLASH-BINARY GEOTHERMAL POWER GENERATION SYSTEM DRIVEN BY LOW-MEDIUM TEMPERATURE GEOTHERMAL SYSTEM

被引:4
|
作者
Luo, Chao [1 ,2 ,3 ,4 ]
Zhao, Jun [2 ]
Wang, Yongzhen [2 ]
Yin, Hongmei [2 ]
An, Qingsong [2 ]
Gong, Yulie [2 ,3 ,4 ]
机构
[1] Huizhou Univ, Sch Architecture & Civil Engn, Huizhou, Guangdong, Peoples R China
[2] Tianjin Univ, Minist Educ, Key Lab Efficient Utilizat Low & Medium Grade Ene, Tianjin, Peoples R China
[3] Chinese Acad Sci, Key Lab Renewable Energy, Guangzhou, Guangdong, Peoples R China
[4] Guangdong Prov Key Lab New & Renewable Energy Res, Guangzhou, Guangdong, Peoples R China
来源
THERMAL SCIENCE | 2020年 / 24卷 / 02期
关键词
geothermal power plant; flash system; organic Rankine cycle; experiment; exergy; efficiency; EXERGOECONOMIC ANALYSIS; MULTIOBJECTIVE OPTIMIZATION; CYCLE; PERFORMANCE; HEAT; SINGLE; PLANT; ORC; CONVERSION;
D O I
10.2298/TSCI181112013L
中图分类号
O414.1 [热力学];
学科分类号
摘要
To match for the different temperature of the geothermal resource and strengthen the flexibility of organic Rankine cycle, a variable capacity power generation superstructure based on flash and organic Rankine cycle for geothermal energy was proposed. A combined flash-binary experimental prototype is newly established to investigate thermodynamic performance both on system and equipment in this paper. Pressured hot water is adopted as the extensive worldwide existed hydrothermal geothermal resource, eliminating the influence of the used heat transfer oil on evaporating process. The experimental results show that there is an optimal mass-flow rate of R245fa under the condition of different heat source temperature. Flash and binary power subsystem dominate the flash-binary power system, respectively, when the heat source temperature is 120 degrees C and 130 degrees C. The isotropic efficiency of modified compressor just between 0.2 and 0.25. The power output of per ton geofluid are 0.78 kWh/t and 1.31 kWh/t, respectively, when the heat source temperature are 120 degrees C and 130 degrees C. These results will predict the operation data of flash-binary power plant driven by the low-medium temperature geothermal water for construction in western of China.
引用
收藏
页码:831 / 842
页数:12
相关论文
共 50 条
  • [31] Combined cycle power unit with a binary system based on waste geothermal brine at Mutnovsk geothermal power plant
    Tomarov G.V.
    Shipkov A.A.
    Nikol’skii A.I.
    Semenov V.N.
    [J]. Thermal Engineering, 2016, 63 (6) : 409 - 413
  • [32] Exergoeconomic, water footprint-based exergoenvironmental impact and optimization of a new flash-binary geothermal power generation system using an improved grey relational method
    Arezoo Sohbatloo
    Nassim Rostami
    Fateme Ahmadi Boyaghchi
    [J]. Journal of Thermal Analysis and Calorimetry, 2022, 147 : 8411 - 8434
  • [33] Comprehensive analysis and multi-objective optimization of a power and hydrogen production system based on a combination of flash-binary geothermal and PEM electrolyzer
    Fan, Guangli
    Yang, Boyuan
    Guo, Peixi
    Lin, Shuchao
    Farkoush, Saeid Gholami
    Afshar, Nima
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (68) : 33718 - 33737
  • [34] Exergoeconomic analysis and multi-objective optimization of a novel combined flash-binary cycle for Sabalan geothermal power plant in Iran
    Aali, A.
    Pourmahmoud, N.
    Zare, V.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 143 : 377 - 390
  • [35] Analysis of geothermal power generation by total flow system with binary cycle
    Wang, Xin-Yue
    Yu, Yue-Feng
    Hu, Da
    Chen, Liang-Le
    Min, Cheng-Hao
    Dong, Zheng-Wen
    [J]. Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2013, 47 (04): : 560 - 564
  • [36] THERMAL DESIGN OF ALKALINE WATER ELECTROLYSIS ASSISTED BY COMBINED FLASH BINARY GEOTHERMAL POWER PLANT
    Kanoglu, Mehmet
    Yilmaz, Ceyhun
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 6A, 2014,
  • [37] Low emission flash-binary and two-phase binary geothermal power plants with water absorption and reinjection of non-condensable gases
    Manente, Giovanni
    Bardi, Alessio
    Lazzaretto, Andrea
    Paci, Marco
    [J]. GEOTHERMICS, 2019, 80 : 155 - 169
  • [38] The optimization of a low-temperature geothermal-driven combined cooling and power system: Thermoeconomic and advanced exergy assessments
    Akhoundi, Mahla
    Gholizadeh, Mohammad
    Deymi-Dashtebayaz, Mahdi
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 96
  • [39] Experimental study on horizontal tube spray falling film evaporator in a low temperature geothermal binary cycle power system
    Hu, Bing
    Guo, Jiajun
    Yang, Yu
    Shao, Youyuan
    [J]. ENERGY REPORTS, 2022, 8 : 187 - 193
  • [40] Experimental study on horizontal tube spray falling film evaporator in low temperature geothermal binary cycle power system
    Hu B.
    Guo J.
    Huang S.
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (07): : 493 - 498