Full-field 3D displacement and strain analysis during low energy impact tests employing a single-camera system

被引:7
|
作者
Felipe-Sese, Luis [1 ]
Lopez-Alba, Elias [2 ]
Diaz, Francisco A. [2 ]
机构
[1] Univ Jaen, Dept Ingn Mecan & Minera, Campus Cientif Tecnol Linares, Linares 23700, Spain
[2] Univ Jaen, Dept Ingn Mecan & Minera, Campus Las Lagunillas, Jaen 23071, Spain
关键词
SOLID MECHANICS MODELS; FRINGE PROJECTION; OPTICAL MEASUREMENTS; IMAGE; VALIDATION; DEFORMATION;
D O I
10.1016/j.tws.2019.106584
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Characterising materials behaviour during dynamics events such as impact require several features related to monitoring and instrumentation which find in full-field techniques one of the main responses due to high spatial and, nowadays, also temporal resolution. 3D-Digital Image Correlation has provided an interesting tool to evaluate the material response during impact testing. It contributes with displacement and strain fields at high frame rates, which represents enormous potential for subsequent analysis. However, 3D-DIC also presents some issues which may condition the experimentation. The first of them is the requirement of a stereoscopic optical system, which lead to important economic issues if high speed cameras are required. Secondly, certain impact arrangements have limited space which make complicated to dispose of a proper stereoscopic system observing an area of interest with a suitable angle that makes it possible r a successful processing. In this work, a recent procedure combining Fringe projection and 2D-DIC is presented as an alternative for impact testing analysis. As main characteristic, the optical arrangement is simplified to only one high speed camera and an additional simple LCD projector which makes it easier the experimentation, reducing significantly the setup cost. To demonstrate that capabilities of FP+2D-DIC as a simpler approach with results comparable to those obtained with 3D-DIC, in this work it was analysed 2, 3, 4, and 5 mm thickness aluminium plates under low speed impacts with different energy levels. Impacts were performed employing an impact tower with a hemispherical impactor, connected to a load cell. During the impact, displacement and strain maps were measured at the non-impacted face of the specimen, using a single camera system implementing the combination of FP and 2D-DIC techniques. Permanent displacement and strain maps were validated with those obtained with a 3D-DIC system, supporting the potential of this FP+2D-DIC approach for impact testing.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A COMPUTATIONAL WORKBENCH FOR REMOTE FULL FIELD 3D DISPLACEMENT AND STRAIN MEASUREMENTS
    Michopoulos, John G.
    Iliopoulos, Athanasios
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2011, VOL 2, PTS A AND B, 2012, : 489 - 498
  • [22] Full-field dynamic displacement and strain measurement using pulsed and high-speed 3D image correlation photogrammetry
    Schmidt, T
    Tyson, J
    Galanulis, K
    [J]. TWO- AND THREE-DIMENSIONAL VISION SYSTEMS FOR INSPECTION, CONTROL, AND METROLOGY, 2004, 5265 : 145 - 156
  • [23] Damage evolution and full-field 3D strain distribution in passively confined concrete
    Li, Peng -Da
    Wu, Yu-Fei
    [J]. CEMENT & CONCRETE COMPOSITES, 2023, 138
  • [24] Full-Field Strain Measurements on Turbomachinery Components using 3D SLDV Technology
    Maguire, Martyn
    Sever, Ibrahim
    [J]. Proceedings of the 12th International AIVELA Conference on Vibration Measurements by Laser and Noncontact Techniques: Advances and Applications, 2016, 1740
  • [25] The full-field displacement intelligent measurement of retaining structures using UAV and 3D reconstruction
    Zhou, Xulin
    Zhu, Qiankun
    Zhang, Qiong
    Du, Yongfeng
    [J]. MEASUREMENT, 2024, 227
  • [26] Full-field 3D deformation measurement: comparison between speckle phase and displacement evaluation
    Khodadad, Davood
    Singh, Alok Kumar
    Pedrini, Giancarlo
    Sjodahl, Mikael
    [J]. APPLIED OPTICS, 2016, 55 (27) : 7735 - 7743
  • [27] Single-camera system for optically tracking freehand motion in 3D: Experimental implementation and evaluation
    Lee, MK
    Cardinal, HN
    Fenster, A
    [J]. MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES, 2001, 4319 : 109 - 120
  • [28] A fast full-field 3D measurement system for BGA coplanarity inspection
    Yen, HN
    Tsai, DM
    [J]. INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2004, 24 (1-2): : 132 - 139
  • [29] A fast full-field 3D measurement system for BGA coplanarity inspection
    H.-N. Yen
    D.-M. Tsai
    [J]. The International Journal of Advanced Manufacturing Technology, 2004, 24 : 132 - 139
  • [30] Integrated full-field digital mammography and 3D breast ultrasound system
    Elbakri, I
    Entrekin, R
    Coad, C
    Danielson, T
    Janer, R
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1818 - 1818