Impact of Temporary Glycemic Target Use in the Hybrid and Advanced Hybrid Closed-Loop Systems

被引:4
|
作者
Dovc, Klemen [1 ,2 ]
Battelino, Tadej [1 ,2 ]
Beck, Roy W. [3 ]
Sibayan, Judy [3 ]
Bailey, Ryan J. [3 ]
Calhoun, Peter [3 ]
Turcotte, Christine [4 ]
Weinzimer, Stuart [5 ]
Schweiger, Darja Smigoc [1 ,2 ]
Nimri, Revital [6 ]
Bergenstal, Richard M. [7 ]
机构
[1] Univ Ljubljana, Univ Med Ctr Ljubljana, Univ Childrens Hosp, Ljubljana, Slovenia
[2] Univ Ljubljana, Fac Med, Ljubljana, Slovenia
[3] Jaeb Ctr Hlth Res Fdn Inc, Tampa, FL USA
[4] Harvard Med Sch, Joslin Diabet Ctr, Boston, MA USA
[5] Yale Univ, Dept Pediat, New Haven, CT USA
[6] Schneider Childrens Med Ctr, Petah Tiqwa, Israel
[7] HealthPartners Inst, Int Diabet Ctr, Minneapolis, MN USA
基金
美国国家卫生研究院;
关键词
Closed-loop systems; Continuous glucose monitoring; Insulin pump; Time in range; INSULIN DELIVERY; EXERCISE; GLUCOSE; ADULTS; ADOLESCENTS;
D O I
10.1089/dia.2022.0153
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Medtronic advanced hybrid closed-loop (AHCL) and MiniMed (TM) 670G hybrid closed-loop (HCL) systems provide the option to temporarily increase the glucose target to 150 mg/dL (8.3 mmol/L). This analysis investigated the efficacy of the AHCL compared with that of the HCL after the use of this setting. Data from 60 participants in the Fuzzy Logic Automated Insulin Regulation (FLAIR) study were used to compare the AHCL and HCL systems after the use of the temporary target (TT), and during analogous periods where this setting was not used. Differences in time in range 70-180 mg/dL between the systems were similar after the use of the TT setting and during analogous non-TT periods (interaction P = 0.87). Similar trends were observed for mean glucose, percentage time >180 mg/dL, and percentage time >250 mg/dL. Differences between AHCL and HCL systems were similar after the use of the TT setting compared with those of non-TT periods.ClinicalTrials.gov NCT03040414
引用
收藏
页码:848 / 852
页数:5
相关论文
共 50 条
  • [31] An Advanced Closed-Loop Control to Improve the Performance of Hybrid Stepper Motors
    Le, Kien Minh
    Van Hoang, Hung
    Jeon, Jae Wook
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (09) : 7244 - 7255
  • [32] Unannounced Meal Challenges Using an Advanced Hybrid Closed-Loop System
    Shalit, Roy
    Minsky, Noga
    Laron-Hirsh, Maya
    Cohen, Ohad
    Kurtz, Natalie
    Roy, Anirban
    Grosman, Benyamin
    Benedetti, Andrea
    Tirosh, Amir
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 (09) : 579 - 588
  • [33] Advanced Hybrid Closed-Loop System Is Associated with Increase in Tighter Glycemic Range-One-Year Observational Study
    Rizzi, Alessandro
    Tartaglione, Linda
    Leo, Maria Laura
    Paoli, Lorenzo Lucaccini
    Tosti, Giulia
    Popolla, Valentina
    Pitocco, Dario
    DIABETES, 2023, 72
  • [34] Safety and Glycemic Outcomes of the MiniMed Advanced Hybrid Closed-Loop (AHCL) System in Subjects with T1D
    Carlson, Anders L.
    Bode, Bruce W.
    Brazg, Ronald L.
    Christiansen, Mark P.
    Garg, Satish K.
    Kaiserman, Kevin
    Kipnes, Mark
    Liljenquist, David R.
    Philis-Tsimikas, Athena
    Pop-Busui, Rodica
    Sherr, Jennifer
    Shulman, Dorothy I.
    Singh, Kamalpreet K.
    Slover, Robert H.
    Thrasher, James
    Chen, Xiaoxiao
    Grosman, Benyamin
    Lee, Scott W.
    Lintereur, Louis J.
    Liu, Margaret
    Parikh, Neha
    Rhinehart, Andrew S.
    Peng, Fen
    Roy, Anirban
    Shin, John
    Wu, Di
    Vigersky, Robert
    DIABETES, 2020, 69
  • [35] Glycaemic outcomes and patient satisfaction after 3 months of use of an advanced hybrid closed-loop system use
    Beato-Vibora, P. I.
    Gallego-Gamero, F.
    Ambrojo-Lopez, A.
    Gil-Poch, E.
    Martin-Romo, I.
    Arroyo-Diez, F. J.
    DIABETOLOGIA, 2021, 64 (SUPPL 1) : 289 - 289
  • [36] Early impact of hybrid closed-loop insulin pump systems in a regional paediatric diabetes population
    Janjua, Sarfaraz
    Norris, Mary
    McCaffrey, Alison
    O'Gorman, Clodagh S.
    Neylon, Orla M.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 : S185 - S185
  • [37] A retrospective study of the use of hybrid closed-loop insulin pump systems for intrapartum diabetes management
    Hopkin, S. T.
    Forde, R.
    DIABETIC MEDICINE, 2023, 40
  • [38] Use of continuous glucose monitoring and hybrid closed-loop therapy in pregnancy
    Benhalima, Katrien
    Yamamoto, Jennifer M.
    DIABETES OBESITY & METABOLISM, 2024,
  • [39] Improvements in Parental Sleep, Fear of Hypoglycemia, and Diabetes Distress With Use of an Advanced Hybrid Closed-Loop System
    Cobry, Erin C.
    Bisio, Alessandro
    Wadwa, R. Paul
    Breton, Marc D.
    DIABETES CARE, 2022, 45 (05) : 1292 - 1295
  • [40] Strategic design for inventory and production planning in closed-loop hybrid systems
    Dev, Navin K.
    Shankar, Ravi
    Choudhary, Alok
    INTERNATIONAL JOURNAL OF PRODUCTION ECONOMICS, 2017, 183 : 345 - 353