Impact of Temporary Glycemic Target Use in the Hybrid and Advanced Hybrid Closed-Loop Systems

被引:4
|
作者
Dovc, Klemen [1 ,2 ]
Battelino, Tadej [1 ,2 ]
Beck, Roy W. [3 ]
Sibayan, Judy [3 ]
Bailey, Ryan J. [3 ]
Calhoun, Peter [3 ]
Turcotte, Christine [4 ]
Weinzimer, Stuart [5 ]
Schweiger, Darja Smigoc [1 ,2 ]
Nimri, Revital [6 ]
Bergenstal, Richard M. [7 ]
机构
[1] Univ Ljubljana, Univ Med Ctr Ljubljana, Univ Childrens Hosp, Ljubljana, Slovenia
[2] Univ Ljubljana, Fac Med, Ljubljana, Slovenia
[3] Jaeb Ctr Hlth Res Fdn Inc, Tampa, FL USA
[4] Harvard Med Sch, Joslin Diabet Ctr, Boston, MA USA
[5] Yale Univ, Dept Pediat, New Haven, CT USA
[6] Schneider Childrens Med Ctr, Petah Tiqwa, Israel
[7] HealthPartners Inst, Int Diabet Ctr, Minneapolis, MN USA
基金
美国国家卫生研究院;
关键词
Closed-loop systems; Continuous glucose monitoring; Insulin pump; Time in range; INSULIN DELIVERY; EXERCISE; GLUCOSE; ADULTS; ADOLESCENTS;
D O I
10.1089/dia.2022.0153
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Medtronic advanced hybrid closed-loop (AHCL) and MiniMed (TM) 670G hybrid closed-loop (HCL) systems provide the option to temporarily increase the glucose target to 150 mg/dL (8.3 mmol/L). This analysis investigated the efficacy of the AHCL compared with that of the HCL after the use of this setting. Data from 60 participants in the Fuzzy Logic Automated Insulin Regulation (FLAIR) study were used to compare the AHCL and HCL systems after the use of the temporary target (TT), and during analogous periods where this setting was not used. Differences in time in range 70-180 mg/dL between the systems were similar after the use of the TT setting and during analogous non-TT periods (interaction P = 0.87). Similar trends were observed for mean glucose, percentage time >180 mg/dL, and percentage time >250 mg/dL. Differences between AHCL and HCL systems were similar after the use of the TT setting compared with those of non-TT periods.ClinicalTrials.gov NCT03040414
引用
收藏
页码:848 / 852
页数:5
相关论文
共 50 条
  • [1] Glycemic control metrics in a cohort of hospitalized patients with type 1 diabetes using hybrid closed-loop and advanced hybrid closed-loop systems
    Medina, Ana Maria Gomez
    Henao-Carrillo, Diana Cristina
    Yepes, Carlos
    Silva, Julio
    Gomzalez, Javier Alberto Gomez
    Cortes, David
    Robledo, Sofia
    Mejia, Gabriela
    Rondon, Martin
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2023, 204
  • [2] Timing of the Pre-exercise Temporary Target with Advanced Hybrid Closed-Loop (AHCL) and Hypoglycemia Risk
    Morrison, Dale
    Kurtz, Natalie
    Cohen, Ohad
    Vigersky, Robert A.
    O'Neal, David N.
    DIABETES, 2023, 72
  • [3] Assessment of Hybrid Closed-Loop Impact upon Glycemic Control, Weight, and Retinopathy
    Gibb, Fraser W.
    Forbes, Shareen
    Dover, Anna R.
    Stimson, Roland H.
    Lyall, Marcus
    DIABETES, 2024, 73
  • [4] On hybrid systems and closed-loop MPC systems
    Bemporad, A
    Heemels, WPMH
    De Schutter, B
    PROCEEDINGS OF THE 40TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-5, 2001, : 1645 - 1650
  • [5] On hybrid systems and closed-loop MPC systems
    Bemporad, A
    Heemels, WPMH
    De Schutter, B
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2002, 47 (05) : 863 - 869
  • [6] Robustness of MiniMed Advanced Hybrid Closed-Loop (AHCL) Algorithm on a Spectrum of Glycemic Control
    Shin, John
    Dai, Zheng
    Niu, Fang
    DIABETES, 2023, 72
  • [7] Use of Advanced Hybrid Closed-Loop System in a Patient with Pancreas Cancer
    Hacisahinogullari, Hulya
    Caklili, Ozge Telci
    Saribeyliler, Goktug
    Rasulova, Nubar
    Selcukbiricik, Ozlem
    Gul, Nurdan
    Uzum, Ayse Kubat
    Karsidag, Kubilay
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (09) : 675 - 676
  • [8] Use of Advanced Hybrid Closed-Loop System during Pregnancy: Strengths and Limitations of Achieving a Tight Glycemic Control
    Giannoulaki, Parthena
    Kotzakioulafi, Evangelia
    Nakas, Alexandros
    Kontoninas, Zisis
    Evripidou, Polykarpos
    Didangelos, Triantafyllos
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (05)
  • [9] Advanced Closed-Loop Control System Improves Postprandial Glycemic Control Compared With a Hybrid Closed-Loop System Following Unannounced Meal
    Garcia-Tirado, Jose
    Diaz, Jenny L.
    Esquivel-Zuniga, Rebeca
    Koravi, Chaitanya L. K.
    Corbett, John P.
    Dawson, Martha
    Wakeman, Christian
    Barnett, Charlotte L.
    Oliveri, Mary C.
    Myers, Helen
    Krauthause, Katie
    Breton, Marc D.
    DeBoer, Mark D.
    DIABETES CARE, 2021, 44 (10) : 2379 - 2387
  • [10] Lived Experience of Advanced Hybrid Closed-Loop Versus Hybrid Closed-Loop: Patient-Reported Outcomes and Perspectives
    Hood, Korey K.
    Laffel, Lori M.
    Danne, Thomas
    Nimri, Revital
    Weinzimer, Stuart A.
    Sibayan, Judy
    Bailey, Ryan J.
    Schatz, Desmond
    Bratina, Natasa
    Bello, Rachel
    Punel, Alina
    Calhoun, Peter
    Beck, Roy W.
    Bergenstal, Richard M.
    Phillip, Moshe
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (12) : 857 - 861