GEANT4 simulation of exit energy in proton medical imaging

被引:2
|
作者
Silva, R. C. L. [1 ]
Denyak, V. [2 ,5 ]
Schelin, H. R. [1 ,5 ]
Hoff, G. [3 ,4 ]
Paschuk, S. A. [5 ]
Setti, J. A. P. [5 ]
机构
[1] Fac Pequeno Principe, Pele Pequeno Principe Res Inst IPPPP, Ave Silva Jardim 1632, BR-80250060 Curitiba, PR, Brazil
[2] Natl Sci Ctr, Kharkov Inst Phys & Technol, Akad Skaya 1, UA-61108 Kharkov, Ukraine
[3] Univ Cagliari, Dept Phys, Sestu Km 0-700, I-09042 Cagliari, Italy
[4] Complesso Univ Monserrato, Sect Cagliari, Natl Inst Nucl Phys INFN, Sestu Km 0-700, I-09042 Cagliari, Italy
[5] Fed Univ Technol Parana UTFPR, Ave Sete Setembro 3165, BR-8023090 Curitiba, PR, Brazil
关键词
Proton medical imaging; GEANT4; Exit energy spectrum; HEAD SCANNER; RADIOGRAPHY; TOMOGRAPHY;
D O I
10.1016/j.radphyschem.2019.05.028
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Imaging techniques using protons as incident particles are currently being actively developed as a substitute for X-ray computed tomography and nuclear magnetic resonance methods in proton therapy. In proton imaging, density resolution depends on the position of the maximum of the exit energy distribution and the width of this distribution which influences uncertainty in the definition of the exit energy. In recent years, many research groups have used the GEANT4 toolkit to simulate proton imaging devices, without, however, detailed analysis of the reproducibility of the physical quantities simulated by the different models in GEANT4 for the case of thick absorbers. In the present report, we performed a careful quantitative comparison of the experimental and simulated parameters of the exit energy spectra that are important for proton imaging. The difference in exit energy between the BERT and BIC models does not exceed 0.5%, while between EMY and EMV models it is always much larger and reaches 2.5% and is accompanied by a significant difference in spectrum shape. The differences between exit energies and widths of the simulated and measured distributions do not exceed 15% and depend on the exit energy (absorber thickness).
引用
收藏
页数:7
相关论文
共 50 条
  • [1] GEANT4 simulation in proton medical imaging: A transport models comparison
    Silva, R. C. L.
    Denyak, V.
    Hoff, G.
    Paschuk, S. A.
    Schelin, H. R.
    Setti, J. A. P.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 172
  • [2] Validation of Geant4 Simulation of Proton Energy Straggling: First Results
    Han, Min Cheol
    Pia, Maria Grazia
    Saracco, Paolo
    [J]. 2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [3] Geant4 Simulation for Education in Medical Application
    Murakami, K.
    Amako, K.
    Jacquemier, J.
    Maire, M.
    Yoshida, H.
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2444 - +
  • [4] A Geant4 simulation for three-dimensional proton imaging of microscopic samples
    Michelet, Claire
    Li, Zhuxin
    Yang, Wen
    Incerti, Sebastien
    Desbarats, Pascal
    Giovannelli, Jean-Francois
    Barberet, Philippe
    Delville, Marie-Helene
    Gordillo, Nuria
    Deves, Guillaume
    Seznec, Herve
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 172 - 180
  • [5] GEANT4 simulation of the effects of Doppler energy broadening in Compton imaging
    Uche, C. Z.
    Cree, M. J.
    Round, W. H.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (03) : 409 - 414
  • [6] GEANT4 simulation of the effects of Doppler energy broadening in Compton imaging
    C. Z. Uche
    M. J. Cree
    W. H. Round
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 409 - 414
  • [7] Geant4 Simulation for Commissioning of Proton Therapy Centre
    Tan, Hong Qi
    Phua, Jun Hao
    Tan, Lloyd
    Ang, Khong Wei
    Lee, James
    Bettiol, Andrew Anthony
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 583 - 587
  • [8] Validation of Geant4 simulation tool for low energy proton induced reactions
    Tran, H. N.
    Marchix, A.
    Letourneau, A.
    Chauvin, N.
    Menelle, A.
    Ott, F.
    Schwindling, J.
    [J]. 22ND MEETING OF THE INTERNATIONAL COLLABORATION ON ADVANCED NEUTRON SOURCES (ICANS XXII), 2018, 1021
  • [9] A Study on Multiplex Proton Imaging Using GEANT4
    Aso, Tsukasa
    Kawashima, Kazuki
    Nishio, Teiji
    Lee, Se Byeong
    Sasaki, Takashi
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1717 - 1719
  • [10] The Geant4 Simulation Toolkit and Applications For the Geant4 Collaboration
    Apostolakis, John
    [J]. MOLECULAR IMAGING: COMPUTER RECONSTRUCTION AND PRACTICE, 2008, : 73 - 92