摘要
A Monte Carlo approach was used to study the effects of Doppler energy broadening on Compton camera performance. The GEANT4 simulation toolkit was used to model the radiation transport and interactions with matter in a simulated Compton camera. The low energy electromagnetic physics model of GEANT4 incorporating Doppler broadening developed by Longo et al. was used in the simulations. The camera had a 9 x 9 cm scatterer and a 10 x 10 cm absorber with a scatterer to-absorber separation of 5 cm. Modelling was done such that only the effects of Doppler broadening were taken into consideration and effects of scatterer and absorber thickness and pixelation were not taken into account, thus a 'perfect' Compton camera was assumed. Scatterer materials were either silicon or germanium and the absorber material was cadmium zinc telluride. Simulations were done for point sources 10 cm in front of the scatterer. The results of the simulations validated the use of the low energy model of GEANT4. As expected, Doppler broadening was found to degrade the Compton camera imaging resolution. For a 140.5 keV source the resulting full-width-at-half-maximum (FWHM) of the point source image without accounting for Doppler broadening and using a silicon scatterer was 0.58 mm. This degraded to 7.1 mm when Doppler broadening was introduced and degraded further to 12.3 mm when a germanium scatterer was used instead of silicon. But for a 511 keV source, the FWHM was better than for a 140 keV source. The FWHM improved to 2.4 mm for a silicon scatterer and 4.6 mm for a germanium scatterer. Our result for silicon at 140.5 keV is in very good agreement with that published by An et al.
引用
收藏
页码:409 / 414
页数:6
相关论文
共 50 条
  • [1] GEANT4 simulation of the effects of Doppler energy broadening in Compton imaging
    C. Z. Uche
    M. J. Cree
    W. H. Round
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 409 - 414
  • [2] New Geant4 Developments for Doppler Broadening Simulation in Compton Scattering - Development of Charge Transfer Simulation Models in Geant4
    Longo, Francesco
    Pandola, Luciano
    Pia, Maria Grazia
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2140 - +
  • [3] GEANT4 Simulation of a 3D Compton Imaging Device
    Lenti, Massimo
    Veltri, Michele
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4175 - 4179
  • [4] Evaluation of double photon coincidence Compton imaging method with GEANT4 simulation
    Yoshihara, Yuri
    Shimazoe, Kenji
    Mizumachi, Yuki
    Takahashi, Hiroyuki
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 873 : 51 - 55
  • [5] GEANT4 simulation of exit energy in proton medical imaging
    Silva, R. C. L.
    Denyak, V.
    Schelin, H. R.
    Hoff, G.
    Paschuk, S. A.
    Setti, J. A. P.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [6] Explicit modeling of timing characteristics in Compton camera simulation with Geant4
    Park, Jin Hyung
    Seo, Hee
    Kim, Chan Hyeong
    Lee, Ju Hahn
    Lee, Chun Sik
    Lee, Jae Sung
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S274 - S275
  • [7] The Geant4 Simulation Toolkit and Applications For the Geant4 Collaboration
    Apostolakis, John
    [J]. MOLECULAR IMAGING: COMPUTER RECONSTRUCTION AND PRACTICE, 2008, : 73 - 92
  • [8] Geant4 simulation of high energy muon interactions
    Bogdanov, AG
    Burkhardt, H
    Ivanchenko, VN
    Kelner, SR
    Kokoulin, RP
    Maire, M
    Rybin, AM
    Urban, L
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2043 - 2047
  • [9] Validation of Geant4 Simulation of Electron Energy Deposition
    Batic, Matej
    Hoff, Gabriela
    Pia, Maria Grazia
    Saracco, Paolo
    Weidenspointner, Georg
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (04) : 2934 - 2957
  • [10] Simulation of low energy neutron recoils with GEANT4
    Scholl, S
    Bauer, M
    Jochum, J
    [J]. Identification of Dark Matter, 2005, : 489 - 493