Parametric study and optimization of a full-scale converter transformer winding

被引:6
|
作者
Tan, Youbo [1 ]
Yu, Xiaoling [1 ]
Ji, Shengchang [2 ]
Zang, Ying [3 ]
Wang, Xiaolin [4 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[3] Shandong Power Equipment Co Ltd, Jinan 250022, Peoples R China
[4] Univ Tasmania, Sch Engn, Hobart, Tas 7001, Australia
基金
中国国家自然科学基金;
关键词
Converter transformer winding; Heat transfer; Colburn-j factor; Thermal performance; JF factor; RENEWABLE ENERGY; HEAT-TRANSFER; FLOW; FIN; EXCHANGER; SYSTEMS;
D O I
10.1016/j.ijheatmasstransfer.2021.121861
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal and hydraulic performance of the converter transformer winding is essential for improving the reliability and economy of the oil-cooled converter transformer. In this paper, a full-scale axisymmetric numerical heat transfer model was developed for a unilateral valve winding of an oil-cooled converter transformer. This model was first validated using data from the reference. Effects of the oil inlet/outlet position and the block washer number on the oil velocity and disc temperature of the winding were then studied under different oil mass flow rates. The thermal, hydraulic and comprehensive performance of the winding was investigated using Colburn-j factor ( j ), Darcy friction factor ( f ) and JF factor (JF), respectively. Finally, the optimal oil inlet/outlet position and block washer number were identified and the performance of the winding in the optimized design was further evaluated. The results showed that both the oil inlet/outlet position and block washer number had a significant impact on the disc temperature of the winding. The number of overheated discs was reduced by 50% when the oil inlet was set near the outside wall of the winding, compared with the conventional design in which the oil inlet was set at the middle of the winding. Furthermore, the maximum and mean temperature rises of the winding were reduced and the comprehensive performance was improved by setting the block washers. The optimal design for the winding was that the oil inlet was allocated near the outside wall of the winding, the number of the block washer was 3 and the oil mass flow rate was 2mo. In this optimal design, the maximum and mean temperature rises of the winding were reduced by 56.1% and 63.9%, respectively, and the comprehensive performance was improved by 145%, compared with the conventional design. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] FULL-SCALE RESEARCH
    WALSKI, TM
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1991, 117 (05): : 519 - 520
  • [22] Full-scale shaking
    不详
    [J]. MECHANICAL ENGINEERING, 2006, 128 (07) : 14 - 14
  • [23] Modeling and process optimization of a full-scale emulsion polymerization reactor
    Copelli, Sabrina
    Barozzi, Marco
    Petrucci, Noemi
    Moreno, Valeria Casson
    [J]. CHEMICAL ENGINEERING JOURNAL, 2019, 358 : 1410 - 1420
  • [24] In-plant optimization of a full-scale Jameson flotation cell
    Mohanty, MK
    [J]. MINERALS ENGINEERING, 2001, 14 (11) : 1531 - 1536
  • [25] Parametric study on the age of air in a full-scale office room using perforated duct diffusers.
    Raphe, Peyman
    Fellouah, Hachimi
    Poncet, Sebastien
    Ameur, Mohamed
    [J]. HELIYON, 2024, 10 (05)
  • [26] Parameterization of a synchronous generator to represent a full-scale converter generator for fault studies
    Garcia, Jorge Martinez
    [J]. WIND ENERGY, 2014, 17 (12) : 1875 - 1890
  • [27] A Full-Scale CMOS Voltage-to-Frequency Converter for WSN Signal Conditioning
    Calvo, B.
    Medrano, N.
    Celma, S.
    [J]. 2010 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, 2010, : 3088 - 3091
  • [28] Full-scale study of Neoballast section for its application in railway tracks: optimization of track design
    M. Sol-Sánchez
    F. Moreno-Navarro
    M. C. Rubio-Gámez
    N. Manzo
    V. Fontseré
    [J]. Materials and Structures, 2018, 51
  • [29] Full-scale study of Neoballast section for its application in railway tracks: optimization of track design
    Sol-Sanchez, M.
    Moreno-Navarro, F.
    Rubio-Gamez, M. C.
    Manzo, N.
    Fontsere, V.
    [J]. MATERIALS AND STRUCTURES, 2018, 51 (02)
  • [30] STRUCTURE AND CONTENT IN CONCEPT ATTAINMENT - A FULL-SCALE STUDY
    WETHERICK, NE
    [J]. BRITISH JOURNAL OF PSYCHOLOGY, 1969, 60 : 347 - +