摘要
Greenhouse gas (GHG) emissions leading to anthropogenic global warming continue to be a major issue for societies worldwide. A major opportunity to reduce emissions is to improve building construction, and in particular the effectiveness of building envelope, which leads to a decrease in operational energy consumption. Improving the performance of a building's thermal envelope can substantially reduce energy consumption from heating, ventilation, and air conditioning while maintaining occupant comfort. In previous work, a computational model of a biomimetic building facade design was found to be effective in temperate climates in an office context. Through a case study example based on animal fur and blood perfusion, this paper tests the hypothesis that biomimetic building facades have a broader application in different building typologies across a range of climate zones. Using bioinspiration for innovation opens new ideas and pathways for technological development that traditional engineering design does not provide. This study exemplifies the process in a building facade, integrating a new form of insulation, heating and cooling. Methods of mathematical modelling and digital simulation methods were used to test the energy reduction potential of the biomimetic facade was tested in a set of operational applications (office, school, and aged care) and across different climate zones (tropical, desert, temperate, and cool continental). Results indicated that the biomimetic facade has potential to reduce energy consumption for all building applications, with the greatest benefit shown in residential aged care (67.1% reduction). Similarly, the biomimetic building facade showed potential to reduce operational services energy consumption in all climate zones, with the greatest energy reductions achieved in the tropical (55.4% reduction) and humid continental climates (55.1% reduction). Through these results the hypothesis was confirmed suggesting that facades engineered to mimic biological functions and processes can improve substantially decrease building operational energy consumption and can be applied in different building classifications and different climate zones. These results would significantly decrease operational greenhouse gas emissions over the lifetime of a building and provide substantial savings in energy bills. Such facades can contribute to the further reduction in greenhouse gas emissions in a broad range of contexts in the built environment and other areas of technology and design. The flexibility and adaptability of biomimetic facades exemplify how biological strategies and characteristics can augment and improve performance in different environments, since the organisms that inspire innovation are already well-adapted to the conditions on earth. This study also exemplified a method by which other biomimetic building envelope features may be assessed. Further work is suggested to assess economic viability and constructability of the proposed facades. [GRAPHICS] .
引用
收藏
页码:493 / 518
页数:26
相关论文
共 50 条
  • [31] Microclimate and building energy consumption: study of different coupling methods
    Malys, Laurent
    Musy, Marjorie
    Inard, Christian
    [J]. ADVANCES IN BUILDING ENERGY RESEARCH, 2015, 9 (02) : 151 - 174
  • [32] Parametric Study on Residential Passive House Building in Different Chinese Climate Zones
    Li, Xing
    Deng, Qinli
    Ren, Zhigang
    Shan, Xiaofang
    Yang, Guang
    [J]. SUSTAINABILITY, 2021, 13 (08)
  • [33] Optimizing thermal insulation of external building walls in different climate zones in Libya
    Elmzughi, Malik
    Alghoul, Samah
    Mashena, Mohamed
    [J]. JOURNAL OF BUILDING PHYSICS, 2021, 45 (03) : 368 - 390
  • [34] Energy Efficiency and Sustainability of Different Building Structures in Latvian Climate
    Jakovics, A.
    Gendelis, S.
    Bandeniece, L.
    [J]. 2ND INTERNATIONAL CONFERENCE ON INNOVATIVE MATERIALS, STRUCTURES AND TECHNOLOGIES, 2015, 96
  • [35] Use of AI Algorithms in Different Building Typologies for Energy Efficiency towards Smart Buildings
    Bagheri, Ali
    Genikomsakis, Konstantinos N.
    Koutra, Sesil
    Sakellariou, Vasileios
    Ioakimidis, Christos S.
    [J]. BUILDINGS, 2021, 11 (12)
  • [36] Future Climate Change on Energy Consumption of Office Buildings in Different Climate Zones of China
    Chen, Yuehao
    Li, Mingcai
    Xiong, Mingming
    Cao, Jingfu
    Li, Ji
    [J]. POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2018, 27 (01): : 45 - 53
  • [37] Exploring the Potential of Climate-Adaptive Container Building Design under Future Climates Scenarios in Three Different Climate Zones
    Shen, Jingchun
    Copertaro, Benedetta
    Zhang, Xingxing
    Koke, Johannes
    Kaufmann, Peter
    Krause, Stefan
    [J]. SUSTAINABILITY, 2020, 12 (01)
  • [38] Potential of integrating PCMs in residential building envelope to reduce cooling energy consumption
    Al-mudhafar, Ahmed H. N.
    Hamzah, Mushtaq Talib
    Tarish, Ali Lateef
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2021, 27
  • [39] Assessment of residential building performances for the different climate zones of Turkey in terms of life cycle energy and cost efficiency
    Mangan, Suzi Dilara
    Oral, Gul Koclar
    [J]. ENERGY AND BUILDINGS, 2016, 110 : 362 - 376
  • [40] Building Facades offer great Potential for Solar Energy Generation
    不详
    [J]. BAUPHYSIK, 2021, 43 (03) : 204 - 204